Hostname: page-component-848d4c4894-ttngx Total loading time: 0 Render date: 2024-06-02T02:26:01.750Z Has data issue: false hasContentIssue false

Development of X-ray silicon microcalorimeters

Published online by Cambridge University Press:  11 June 2009

P. Agnese*
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
A. Aliane
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
A. Gasse
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
F. Demoro
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
Y. Gobil
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
S. Ballerand
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
C. Beccia
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
I. Borel
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
J. Goupy
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
H. Ribot
Affiliation:
CEA-LETI, Minatec 17 rue des Martyrs, 38054 Grenoble Cedex 9, France
C. Pigot
Affiliation:
CEA/DAPNIA/SAp, SEDI, Bât. 709, CEA-Saclay, 91191 Gif-sur-Yvette Cedex, France
J.-L. Sauvageot
Affiliation:
CEA/DAPNIA/SAp, SEDI, Bât. 709, CEA-Saclay, 91191 Gif-sur-Yvette Cedex, France
V. Szeflinski
Affiliation:
CEA/DAPNIA/SAp, SEDI, Bât. 709, CEA-Saclay, 91191 Gif-sur-Yvette Cedex, France
F. Perot
Affiliation:
CEA/DAPNIA/SAp, SEDI, Bât. 709, CEA-Saclay, 91191 Gif-sur-Yvette Cedex, France
E. Gremion
Affiliation:
CEA/DAPNIA/SAp, SEDI, Bât. 709, CEA-Saclay, 91191 Gif-sur-Yvette Cedex, France
X. de la Brose
Affiliation:
CEA/DAPNIA/SAp, SEDI, Bât. 709, CEA-Saclay, 91191 Gif-sur-Yvette Cedex, France
X-F. Navick
Affiliation:
CEA/DAPNIA/SAp, SEDI, Bât. 709, CEA-Saclay, 91191 Gif-sur-Yvette Cedex, France
Get access

Abstract

X-ray microcalorimeter arrays are well suited to address key problems in high-energy astrophysics; this microcalorimeter uses thermometers based on technology IDT (Implanted Diffused Thermometer) implemented in silicon-on-insulator (SOI) wafers. This work presents our results on the test (measurements) of the thermometer prototype.

Type
Research Article
Copyright
© EAS, EDP Sciences, 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Aliane, A., et al., 2008a, J. Low Temp. Phys., 151
Aliane, A., 2009, Ph.D. Thesis of INPG, France
Aliane, A., et al., 2008b, Nuclear Instr. Meth. Phys. Res. A, 594, 210214 CrossRef
See http://astro.esa.int/SA-general/projects/XEUS