Hostname: page-component-848d4c4894-x24gv Total loading time: 0 Render date: 2024-06-06T11:17:17.770Z Has data issue: false hasContentIssue false

Amidst the CAUTI Metrics Hurley Burly, a Sustained SURly Success Adaptable for Reducing Other Nosocomial Infections

Published online by Cambridge University Press:  02 November 2020

Emil Lesho
Affiliation:
Rochester Regional Health
Robert Clifford
Affiliation:
Cavia Partners
Kelly Vore
Affiliation:
Rochester Regional Health
Jennifer Fede
Affiliation:
Rochester Regional Health
Balazs Zsenits
Affiliation:
Rochester Regional Health
Dawn Riedy
Affiliation:
Rochester Regional Health
Jose Alcantara
Affiliation:
Rochester Regional Health
Deborah Stamps
Affiliation:
Rochester Regional Health
Melissa Bronstein
Affiliation:
Rochester Regional Health
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: Surveillance metrics for catheter-associated urinary tract infections (CAUTIs) are subject to ongoing debate and refinement to best capture infectious catheter-related harm (ICRH) and noninfectious catheter-related harm (NCRH). Indwelling urinary catheters cause 5 times more NCRH than ICRH. The commonly used standardized infection ratio (SIR) does not fully capture NCRH nor the impact of prevention efforts in all settings. Alternatively, device utilization rates and ratios (DUR) do not reflect differences in other factors that may describe levels of device use. DUR lose comparability over time and across settings and can mask truly effective interventions by selecting for a higher risk group of catheterized patients. Experts now advocate use of the standardized utilization ratio (SUR). We sought to implement a multidimensional intervention to reduce exposure risk, CAUTI, and NCRH across a 5-hospital healthcare system, totaling 1,692 acute-care beds. Methods: The intervention comprised the following elements: (1) an interactive educational campaign comprising one-on-one engagements between infection preventionists and frontline providers, encouraging the use of female external urinary collection devices and male custom-fitted condom catheters, rewarding overall participation, device utilization, hand hygiene, and CAUTI rates; (2) educational emails to all staff from top executives; (3) increasing the urinalysis reflex to culture threshold from >5 to ≥10 WBCs; and (4) clinical decision support (CDS) for ordering urine cultures for patients with indwelling catheters and for encouraging Foley catheter alternatives and catheter removal. Monthly, quality department representatives discuss unit level DURs with managers, who then discuss patient-level device use at daily huddles with physicians and advanced practice providers. Significance was determined using the 2-tailed t test. The results are listed in Table 1. Discussion: One year after the intervention, use of device alternatives increased 5-fold, CDS-driven ordering predominated, and the SIR and SUR remained significantly decreased. These successes are especially notable because , a ventricular-assist device program was launched in the postintervention period. By the end of the study, the program became the second-busiest of its type in the United States, resulting in a group of patients at high risk of device use and infection in the postintervention period, but absent in the preintervention period. numerous reports of effective interventions for reducing CAUTI have been published, we found no large studies using the SUR as the main metric. The limitations of this study include the lack of a population SIR and data pertaining to catheter-related bacteriuria and antibiotic usage. However, this approach is easily customizable to any infection, device, and diagnostic test.

Disclosures: None

Funding: None

Type
Poster Presentations
Copyright
© 2020 by The Society for Healthcare Epidemiology of America. All rights reserved.