Hostname: page-component-848d4c4894-nr4z6 Total loading time: 0 Render date: 2024-06-06T02:14:06.033Z Has data issue: false hasContentIssue false

Breakthrough of the Mini-Cyclotron Mass Spectrometer for 14C Analysis

Published online by Cambridge University Press:  18 July 2016

Maobai Chen
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Deming Li
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Senlin Xu
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Guosheng Chen
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Ligong Shen
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Xiangshun Lu
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Weiyu Zhang
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Yuexiang Zhang
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Zongkun Zhong
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Yingji Zhang
Affiliation:
Shanghai Institute of Nuclear Research, Academia Sinica, P.O. Box 800204, Shanghai 201800 and T. D. Lee Physics Laboratory, Fudan University, Shanghai 200433 China
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

We present results of current measurements on the super-sensitive mini-cyclotron as an accelerator mass spectrometer, successfully developed at Shanghai Institute of Nuclear Research (SINR). We describe new ideas and unique techniques adopted for increasing the transmission efficiency in the injection, acceleration and extraction region, for eliminating various backgrounds and for improving the precision of 14C analysis, which have led to the breakthrough of our Shanghai Mini-Cyclotron Accelerator Mass Spectrometry project. We also discuss further development of the prototype facility.

Type
V. Advances in Measurement Techniques
Copyright
Copyright © the Department of Geosciences, The University of Arizona 

References

Alvarez, L. W. 1981 The early days of accelerator mass spectrometry. In Kutschera, W., ed., Proceedings of the Symposium on Accelerator Mass Spectrometry. ANL/PHY 81-1, Springfield, National Technical Information Service: 115.Google Scholar
Bertsche, K. J., Karadi, G. A., Muller, R. A. and Paulson, G. C. 1990 Detection of radiocarbon in the cyclotrino. In Yiou, F. and Raisbeck, G. M., eds., Proceedings of the 5th International Conference on Accelerator Mass Spectrometry. Nuclear Instruments and Methods in Physics Research B52: 398402.Google Scholar
Chen, M. B., Gao, W. Z. and Li, D. M. 1989 Design criteria on a mini cyclotron as a mass spectrometer for dating. Nuclear Instrument and Methods in Physics Research A278: 402408.Google Scholar
Chen, M. B., Li, D. M. and Gao, W. Z. 1989 Adopting a non-sinusoidal wave dee voltage in minicyclotron as mass spectrometers for dating. Nuclear Instruments and Methods in Physics Research A278: 409416.Google Scholar
Chen, M. B., Xu, S.L. and Li, D. M. 1990 Determination of the shape of the dee electrodes in the SINR minicyclotron used as AMS for 14C dating. Nuclear Instrument and Methods in Physics Research A297: 4759.CrossRefGoogle Scholar
Clark, D. 1984 Cyclotrons as mass spectrometers. In Marti, F., ed., Proceedings of the 10th International Conference on Cyclotrons. New York, The Institute of Electrical and Electronics Engineers: 534539.Google Scholar
Friedman, P. G., Bertsche, K. J., Michel, M. C., Morris, D. E., Muller, R. A. and Tans, P. P. 1988 Low background-rate detector for 40 keV ions using a conversion dynode and a microchannel-plate electron multiplier to reject low-energy ions, electrons, and photons. Review of Scientific Instruments 59(1): 98111.Google Scholar
Lu, X. S. (ms.) 1992 Study of Effects of Non-Ideal Factors on the Minicyclotron as AMS. Master's dissertation. Shanghai Institute of Nuclear Research: 105 p.Google Scholar
Muller, R. A. 1977 Radioisotope dating with a cyclotron. Science 196: 489494.Google Scholar
Purser, K. H. 1992 A high throughput 14C accelerator mass spectrometer. In Long, A. and Kra, R. S., eds., Proceedings of the 14th International Radiocarbon Conference. Radiocarbon 34(3): 458467.Google Scholar
Welch, J. J., Bertsche, K. J., Friedman, P. G., Morris, D. E., Muller, R. A. and Tans, P. P. 1987 A low energy cyclotron for radiocarbon dating. Nuclear Instruments and Methods in Physics Research B18: 202214.Google Scholar
Zhang, Y. G., Wei, Y. G., Wang, Q. Y. and Qian, W. G. 1991 A position-sensitive microchannel-plate detector for 27 keV ions. Nuclear Instruments and Methods in Physics Research A302: 7682.Google Scholar