Hostname: page-component-857557d7f7-v2cwp Total loading time: 0 Render date: 2025-11-29T08:13:22.461Z Has data issue: false hasContentIssue false

Design and research of a multi-mode hip joint assistive mechanism based on a double cam

Published online by Cambridge University Press:  27 November 2025

Xuegong Huang*
Affiliation:
School of Mechanical Engineering, Nanjing University of Science and Technology , Nanjing, China
Zijun Guo
Affiliation:
School of Mechanical Engineering, Nanjing University of Science and Technology , Nanjing, China
Yutong Zhai
Affiliation:
School of Mechanical Engineering, Nanjing University of Science and Technology , Nanjing, China
*
Corresponding author: Xuegong Huang; Email: huangxg@njust.edu.cn

Abstract

Lower limb-assisted exoskeletons can provide payloads and support, but the hip joints of current lower limb-assisted exoskeletons have problems such as single mechanisms, few degrees of freedom, and limitations in the types of gaits that can be acted upon. To address these problems, a novel double-cam hip joint assist mechanism is proposed for walking, running, and carrying gait situations. The double cam and two rectangular compression springs with different stiffness are used to satisfy the differences in exoskeleton assistance requirements in multiple gaits. First, biomechanical simulation of walking, running, and carrying movements is carried out with OpenSim to obtain the hip joint angle and torque data, and then the structural design of the assist mechanism is carried out. Hip joint angle planning and contour solving are carried out for the contour lines of the cams, so that the cam contour lines are assist according to different hip joint angles, and the stiffness of compression springs is determined by D’Alembert’s principle, and the assist torques are analyzed. Meanwhile, a human–machine coupling model was established for theoretical analysis. Finally, the muscle power change curves were exported using OpenSim, and the assistance was verified by comparison.

Information

Type
Research Article
Copyright
© The Author(s), 2025. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable

References

Zeng, Y., Gan, J. and Li, C., “Morphological design of military active exoskeleton robot based on “sense of power”,” Design. 34(10), 132134 (2021).Google Scholar
Zhang, Z., Cao, W., Chen, C., Yu, H., Wu, X. and Meng, Q., “Design and Simulation of a Hip Exoskeleton for Lateral Walking,” In: 2021 IEEE International Conference on Real-time Computing and Robotics (RCAR), Xining, China (2021) pp. 13111315.Google Scholar
Chen, B., Zi, B., Qin, L. and Pan, Q., “State-of-the-art research in robotic hip exoskeletons: A general review,” J. Orthop. Translat. 20, 413 (2020).10.1016/j.jot.2019.09.006CrossRefGoogle ScholarPubMed
Kazerooni, H., Steger, R. and Huang, L., “Hybrid control of the Berkeley lower extremity exoskeleton (BLEEX),” Int. J. Robot. Res. 25(5–6), 561573 (2006).10.1177/0278364906065505CrossRefGoogle Scholar
Sellaouti, R. and Ouezdou, F. B., “Design and control of a 3DOFs parallel actuated mechanism for biped application,” Mech. Mach. Theory. 40(12), 13671393 (2005).10.1016/j.mechmachtheory.2005.02.002CrossRefGoogle Scholar
Sankai, Y., “Leading Edge of Cybernics: Robot Suit Hal,” In: 2006 SICE-ICASE International Joint Conference, Busan, Korea (2006) pp. P1.10.1109/SICE.2006.314982CrossRefGoogle Scholar
Zhang, J., Yang, C. and Chen, Y., “Exoskeleton arm with force feedback for robot bilateral teleoperation,”Prog. Nat. Sci. 17(8), 948955 (2007).Google Scholar
Zoss, A. B., Actuation design and implementation for lower extremity human exoskeletons (ProQuest, 2006).Google Scholar
Toyama, S. and Yamamoto, G., “Development of Wearable-Agri-Robot Mechanism for Agricultural Work,” In: 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems, St. Louis, MO, USA (2009) pp. 58015806.Google Scholar
Yang, J., Park, J., Kim, J., Park, S. and Lee, G., “Reducing the energy cost of running using a lightweight, low-profile elastic exosuit,” J. Neuroeng. Rehabil. 18(1), 129 (2021).10.1186/s12984-021-00928-xCrossRefGoogle ScholarPubMed
Cao, W., Chen, C., Hu, H., Fang, K. and Wu, X., “Effect of hip assistance modes on metabolic cost of walking with a soft exoskeleton,” IEEE Trans. Autom. Sci. Eng. 18(2), 426436 (2020).10.1109/TASE.2020.3027748CrossRefGoogle Scholar
Shen, Z., Sam, S., Allison, G. and Cui, L., “A simulation-based study on a clutch-spring mechanism reducing human walking metabolic cost,” Int. J. Mech. Eng. Robot. Res. 7(1), 5560 (2018).Google Scholar
Williams, J. R., Cuddeback, C. F., Fang, S., Colley, D., Enlow, N., Cox, P., Pridham, P. and Lerner, Z. F., “OpenExo: An open-source modular exoskeleton to augment human function,” Sci. Robot. 10(103), eadt1591 (2025).10.1126/scirobotics.adt1591CrossRefGoogle ScholarPubMed
Ma, Z., Wang, Y., Zhang, T. and Liu, J., “Reconfigurable exomuscle system employing parameter tuning to assist hip flexion or ankle plantarflexion,” IEEE/ASME Trans. Mechatronics, 112 (2025). Early Access. doi: 10.1109/TMECH.2025.3526987.Google Scholar
Sun, L., Deng, A., Wang, H., Zhou, Y. and Song, Y., “A soft exoskeleton for hip extension and flexion assistance based on reinforcement learning control,” Sci. Rep. 15(1), 5435 (2025).10.1038/s41598-025-89764-wCrossRefGoogle ScholarPubMed
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N. and Walsh, C. J., “Opportunities and challenges in the development of exoskeletons for locomotor assistance,” Nat. Biomed. Eng. 7(4), 456472 (2023).10.1038/s41551-022-00984-1CrossRefGoogle ScholarPubMed
Quínto, L., Pinheiro, P., Gonçalves, S. B., Roupa, I., Simoes, P. and da Silva, M. T., “Analysis of a passive ankle exoskeleton for reduction of metabolic costs during walking,” Def. Tech. 37, 6268 (2024).10.1016/j.dt.2023.11.015CrossRefGoogle Scholar
Perry, J. and Burnfield, J. M., Gait Analysis: Normal and Pathological Function (2nd edn. SLACK Incorporated, Thorofare, NJ, (2010)Google Scholar
Yeung, H., Major qualifying projects April 2019 Soft Ankle Exosuit for correction of foot drop, major qualifying project (MQP) report (Worcester polytechnic institute (WPI), 2019).Google Scholar
Akhavanfar, M., Uchida, T. K., Clouthier, A. L. and Graham, R. B., “Sharing the load: Modeling loads in OpenSim to simulate two-handed lifting,” Multibody Syst. Dyn. 54, 213234 (2022).10.1007/s11044-021-09808-7CrossRefGoogle Scholar
Shao, Y., Xiang, Z., Liu, H. and Li, L., “Conceptual design and dimensional synthesis of cam-linkage mechanisms for gait rehabilitation,” Mech. Mach. Theory 104, 3142 (2016).10.1016/j.mechmachtheory.2016.05.018CrossRefGoogle Scholar
Chang, W. T., Hu, Y. E. and Chang, W. C., “An improved design for rotating balance of assembled type conjugate disk cams,” Mech. Mach. Theory 171, 104700 (2022).10.1016/j.mechmachtheory.2021.104700CrossRefGoogle Scholar
Wu, J., Zeng, L., Ruan, Q., Guo, J., Yang, H., Jing, L. and Yao, Y. a., “Reconfiguration and compensation design method for single-DoF closed-chain leg mechanism,” Mech. Mach. Theory 204, 105834 (2024).10.1016/j.mechmachtheory.2024.105834CrossRefGoogle Scholar