Skip to main content
×
×
Home
  • Print publication year: 2017
  • Online publication date: June 2017

Chapter 20 - Ultrasound-Guided Procedures

from Part II - Ultrasound
Recommend this book

Email your librarian or administrator to recommend adding this book to your organisation's collection.

Clinical Emergency Radiology
  • Online ISBN: 9781107588622
  • Book DOI: https://doi.org/10.1017/9781107588622
Please enter your name
Please enter a valid email address
Who would you like to send this to *
×
1.Chen, L, Hsiao, AL, Moore, CL, et al.: Utility of bedside bladder ultrasound before urethral catheterization in young children. Pediatrics 2005;115(1):108–11.
2.Witt, M, Baumann, BM, McCans, K: Bladder ultrasound increases catheterization success in pediatric patients. Acad Emerg Med 2005;12(4):371–4.
3.Chu, RW, Wong, YC, Luk, SH, Wong, SN: Comparing suprapubic urine aspiration under real-time ultrasound guidance with conventional blind aspiration. Acta Paediatr 2002;91(5):512–16.
4.Garcia-Nieto, V, Navarro, JF, Sanchez-Almeida, E, Garcia-Garcia, M: Standards for ultrasound guidance of suprapubic bladder aspiration. Pediatr Nephrol 1997;11(5):607–9.
5.Gochman, RF, Karasic, RB, Heller, MB: Use of portable ultrasound to assist urine collection by suprapubic aspiration. Ann Emerg Med 1991;20(6):631–5.
6.Goldberg, BB, Meyer, H: Ultrasonically guided suprapubic urinary bladder aspiration. Pediatrics 1973;51(1):70–4.
7.Kiernan, SC, Pinckert, TL, Keszler, M: Ultrasound guidance of suprapubic bladder aspiration in neonates. J Pediatr 1993;123(5):789–91.
8.Ozkan, B, Kaya, O, Akdag, R, et al.: Suprapubic bladder aspiration with or without ultrasound guidance. Clin Pediatr (Phila) 2000;39(10):625–6.
9.Sagi, EF, Alpan, G, Eyal, FG, et al.: Ultrasonic guidance of suprapubic aspiration in infants. J Clin Ultrasound 1983;11(6):347–8.
10.Raad, I: Intravascular-catheter–related infections. Lancet 1998;351(9106):893–8.
11.Merrer, J, De Jonghe, B, Golliot, F, et al.: Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial. JAMA 2001;286(6):700–7.
12.Gallieni, M, Cozzolino, M: Uncomplicated central vein catheterization of high risk patients with real time ultrasound guidance. Int J Artif Organs 1995;18(3):117–21.
13.Hind, D, Calvert, N, McWilliams, R, et al: Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 2003;327(7411):361.
14.Kohn, L, Corrigan, J, Molla, S, Donaldson, M: To err is human: building a safer health system. Washington, DC: Committee on Quality of Health Care in America, Institute of Medicine, 1999.
15.Shojania, KG, Duncan, BW, McDonald, KM, Wachter, R, eds: Making health care safer: a critical analysis of patient safety practices. Evidence report/technology assessment no. 43. Rockville, MD: Agency for Healthcare Research and Quality, 2001. AHRQ Publication No. 01-E058.
16.Grebenik, CR, Boyce, A, Sinclair, ME, et al.: NICE guidelines for central venous catheterization in children: is the evidence base sufficient? Br J Anaesth 2004;92(6):827–30.
17.Domino, KB, Bowdle, TA, Posner, KL, et al.: Injuries and liability related to central vascular catheters: a closed claims analysis. Anesthesiology 2004;100(6):1411–18.
18.McGee, DC, Gould, MK: Preventing complications of central venous catheterization. N Engl J Med 2003;348(12):1123–33.
19.Terai, C, Anada, H, Matsushima, S, et al.: Effects of mild Trendelenburg on central hemodynamics and internal jugular vein velocity, cross-sectional area, and flow. Am J Emerg Med 1995;13(3):255–8.
20.Lobato, EB, Florete, OG Jr, Paige, GB, Morey, TE: Cross-sectional area and intravascular pressure of the right internal jugular vein during anesthesia: effects of Trendelenburg position, positive intrathoracic pressure, and hepatic compression. J Clin Anesth 1998;10(1):15.
21.Mallory, DL, Shawker, T, Evans, RG, et al.: Effects of clinical maneuvers on sonographically determined internal jugular vein size during venous cannulation. Crit Care Med 1990;18(11):1269–73.
22.Armstrong, PJ, Sutherland, R, Scott, DH: The effect of position and different manoeuvres on internal jugular vein diameter size. Acta Anaesthesiol Scand 1994;38(3):229–31.
23.Gordon, AC, Saliken, JC, Johns, D, et al.: US-guided puncture of the internal jugular vein: complications and anatomic considerations. J Vasc Interv Radiol 1998;9(2):333–8.
24.Gualtieri, E, Deppe, SA, Sipperly, ME, Thompson, DR: Subclavian venous catheterization: greater success rate for less experienced operators using ultrasound guidance. Crit Care Med 1995;23(4):692–7.
25.Hilty, WM, Hudson, PA, Levitt, MA, Hall, JB: Real-time ultrasound-guided femoral vein catheterization during cardiopulmonary resuscitation. Ann Emerg Med 1997;29(3):331–6.
26.Yanay, O, Vaughan, DJ, Diab, M, et al.: Retained wooden foreign body in a child’s thigh complicated by severe necrotizing fasciitis: a case report and discussion of imaging modalities for early diagnosis. Pediatr Emerg Care 2001;17(4):354–5.
27.Boyse, TD, Fessell, DP, Jacobson, JA, et al.: Ultrasound of soft-tissue foreign bodies and associated complications with surgical correlation. Radiographics 2001;21(5):1251–6.
28.Hung, YT, Hung, LK, Griffith, JF, et al.: Ultrasound for the detection of vegetative foreign body in the hand – a case report. Hand Surg 2004;9(1):83–7.
29.Graham, DD: Ultrasound in the emergency department: detection of wooden foreign bodies in the soft tissues. J Emerg Med 2002;22(1):75–9.
30.Soudack, M, Nachtigal, A, Gaitini, D: Clinically unsuspected foreign bodies: the importance of sonography. J Ultrasound Med 2003;22(12):1381–5.
31.Lammers, RL, Magill, T: Detection and management of foreign bodies in soft tissue. Emerg Med Clin North Am 1992;10(4):767–81.
32.Schlager, D: Ultrasound detection of foreign bodies and procedure guidance. Emerg Med Clin North Am 1997;15(15):895912.
33.Trautlein, JJ, Lambert, RL, Miller, J: Malpractice in the emergency department – review of 200 cases. Ann Emerg Med 1984;13(9 p. 1):709–11.
34.Gilbert, FJ, Campbell, RS, Bayliss, AP: The role of ultrasound in the detection on non-radiopaque foreign bodies. Clin Radiol 1990;41(2):109–12.
35.Shiels, WE, Babcock, D, Wilson, J, Burch, R: Localization and guided removal of soft-tissue foreign bodies with sonography. AJR Am J Roentgenol 1990;155(6):1277–81.
36.Rockett, MS, Gentile, SC, Gudas, CJ, et al.: The use of ultrasonography for the detection of retained wooden foreign bodies in the foot. J Foot Ankle Surg 1995;34(5):478–84; discussion 510–11.
37.Crawford, R, Matheson, AB: Clinical value of ultrasonography in the detection and removal of radiolucent foreign bodies. Injury 1989;20(6):341–3.
38.Blankstein, A, Cohen, I, Heiman, Z, et al.: Localization, detection and guided removal of soft tissue in the hands using sonography. Arch Orthop Trauma Surg 2000;120(9):514–17.
39.Jacobson, JA, Powell, A, Craig, JG, et al.: Wooden foreign bodies in soft tissue: detection with ultrasound. Radiology 1998;206(7):45–8.
40.Bradley, M, Kadzombe, E, Simms, P, Eyes, B: Percutaneous ultrasound guided extraction of non-palpable soft tissue foreign bodies. Arch Emerg Med 1992;9:181–4.
41.Heller, M, Jehle, D: Ultrasound in emergency medicine. Oxford, UK: WB Saunders, 1995.
42.Lyon, M, Brannam, L, Johnson, D, et al.: Detection of soft tissue foreign bodies in the presence of soft tissue gas. J Ultrasound Med 2004;23(5):677–81.
43.Gooding, GA, Hardiman, T, Sumers, M, et al.: Sonography of the hand and foot in foreign body detection. J Ultrasound Med 1987;6(8):441–7.
44.Banerjee, B, Das, RK: Sonographic detection of foreign bodies of the extremities. Br J Radiol 1991;64(758):107–12.
45.Schlager, D, Johnson, T, Mcfall, R: Safety of imaging exploding bullets with ultrasound. Ann Emerg Med 1996;28(13):183–7.
46.Turner, J, Wilde, CH, Hughes, KC, et al.: Ultrasound-guided retrieval of small foreign objects in subcutaneous tissue. Ann Emerg Med 1997;29(5):731–4.
47.Schlager, D: Ultrasound detection of foreign bodies and procedure guidance. Emerg Med Clin North Am 1997;15(15):895912.
48.Oikarinen, KS, Neiminen, T, Makarainen, H, Pyhtinen, J: Visibility of foreign bodies in soft tissue in plain radiographs, computed tomography, magnetic resonance imaging, and ultrasound: an in vitro study. Int J Oral Maxillofac Surg 1993;22(2):119–24.
49.Scanlan, KA: Sonographic artifacts and their origins. AJR Am J Roentgenol 1991;156(6):1267–72.
50.Hill, R, Conron, R, Greissinger, P, Heller, M: Ultrasound for the detection of foreign bodies in human tissue. Ann Emerg Med 1997;29(10):353–6.
51.Fornage, BD: The hypoechoic normal tendon: a pitfall. J Ultrasound Med 1987;6(1):1922.
52.Leung, A, Patton, A, Navoy, J, Cummings, RJ: Intraoperative sonography-guided removal of radiolucent foreign bodies. J Pediatr Orthop 1998;18(2):259–61.
53.Orlinsky, M, Knittel, P, Feit, T, et al.: The comparative accuracy of radiolucent foreign body detection using ultrasonography. Am J Emerg Med 2000;18(6):401–3.
54.Nelson, AL, Sinow, RM: Real-time ultrasonographically guided removal of nonpalpable and intramuscular Norplant capsules. Am J Obstet Gynecol 1998;78(12):1185–93.
55.Frankel, DA, Bargiela, A, Bouffard, JA: Synovial joints: evaluation of intraarticular bodies with US. Radiology 1998;206(16):41–4.
56.Manthey, DE, Storrrow, AB, Milbourn, JM, Wagner, BJ: Ultrasound versus radiography in the detection of soft-tissue foreign bodies. Ann Emerg Med 1996;28(11):79.
57.Teisen, HG, Torfing, KF, Skjodt, T: Ultrasound pinpointing of foreign bodies: an in vitro study. Ultraschall Med 1988;9(3):135–7.
58.Blankstein, A, Cohen, I, Heiman, Z, et al.: Ultrasonography as a diagnostic modality and therapeutic adjuvant in the management of soft tissue foreign bodies in the lower extremities. Isr Med Assoc J 2001;3(6):411–13.
59.Tayal, VS, Nicks, BA, Norton, HJ: Emergency ultrasound evaluation of symptomatic nontraumatic pleural effusions. Am J Emerg Med 2006;24(7):782–6.
60.Diacon, AH, Brutsche, MH, Soler, M: Accuracy of pleural puncture sites: a prospective comparison of clinical examination with ultrasound. Chest 2003;123(2):436–41.
61.Bartter, T, Mayo, PD, Pratter, MR, et al.: Lower risk and higher yield for thoracentesis when performed by experienced operators. Chest 1993;103(6):1873–6.
62.Collins, TR, Sahn, SA: Thoracocentesis: clinical value, complications, technical problems, and patient experience. Chest 1987;91(6):817–22.
63.Grogan, DR, Irwin, RS, Channick, R, et al.: Complications associated with thoracentesis: a prospective, randomized study comparing three different methods. Arch Intern Med 1990;150(4):873–7.
64.Seneff, MG, Corwin, RW, Gold, LH, Irwin, RS: Complications associated with thoracocentesis. Chest 1986;90(1):97100.
65.Jones, PW, Moyers, JP, Rogers, JT, et al.: Ultrasound-guided thoracentesis: is it a safer method? Chest 2003;123(2):418–23.
66.Mayo, PH, Goltz, HR, Tafreshi, M, Doelken, P: Safety of ultrasound-guided thoracentesis in patients receiving mechanical ventilation. Chest 2004;125(3):1059–62.
67.Blaivas, M, Lyon, M, Duggal, S: A prospective comparison of supine chest radiography and bedside ultrasound for the diagnosis of traumatic pneumothorax. Acad Emerg Med 2005;12(9):844–9.
68.Coley, BD, Shiels, WE II, Hogan, MJ: Diagnostic and interventional ultrasonography in neonatal and infant lumbar puncture. Pediatr Radiol 2001;31(6):399402.
69.Cork, RC, Kryc, JJ, Vaughan, RW: Ultrasonic localization of the lumbar epidural space. Anesthesiology 1980;52(6):513–16.
70.Currie, JM: Measurement of the depth to the extradural space using ultrasound. Br J Anaesth 1984;56(4):345–7.
71.Peterson, MA, Abele, J: Bedside ultrasound for difficult lumbar puncture. J Emerg Med 2005;28(2):197200.
72.Sandoval, M, Shestak, W, Sturmann, K, Hsu, C: Optimal patient position for lumbar puncture, measured by ultrasonography. Emerg Radiol 2004;10(4):179–81.
73.Wallace, DH, Currie, JM, Gilstrap, LC, Santos, R: Indirect sonographic guidance for epidural anesthesia in obese pregnant patients. Reg Anesth 1992;17(4):233–6.
74.Nomura, JT, Leech, SJ, Shenbagamurthi, S, et al.: A randomized controlled trial of ultrasound-assisted lumbar puncture. J Ultrasound Med 2007;26(10):1341–8.
75.Cattau, EL Jr, Benjamin, SB, Knuff, TE, Castell, DO: The accuracy of the physical examination in the diagnosis of suspected ascites. JAMA 1982;247(8):1164–6.
76.Nazeer, SR, Dewbre, H, Miller, AH: Ultrasound-assisted paracentesis performed by emergency physicians vs the traditional technique: a prospective, randomized study. Am J Emerg Med 2005;23(3):363–7.
77.Bard, C, Lafortune, M, Breton, G: Ascites: ultrasound guidance or blind paracentesis? CMAJ 1986;135(3):209–10.
78.Feigenbaum, H, Waldhausen, JA, Hyde, LP: Ultrasound diagnosis of pericardial effusion. JAMA 1965;191:711–14.
79.Mazurek, B, Jehle, D, Martin, M: Emergency department echocardiography in the diagnosis and therapy of cardiac tamponade. J Emerg Med 1991;9(1–2):2731.
80.American College of Surgeons (ACS) Committee on Trauma: Advanced trauma life support course for doctors: student course manual, 7th ed. Chicago: ACS, 2004.
81.Guberman, BA, Fowler, NO, Engel, PJ, et al.: Cardiac tamponade in medical patients. Circulation 1981;64(3):633–40.
82.Wong, B, Murphy, J, Chang, CJ, et al.: The risk of pericardiocentesis. Am J Cardiol 1979;44(6):1110–14.
83.Vayre, F, Lardoux, H, Pezzano, M, et al.: Subxiphoid pericardiocentesis guided by contrast two-dimensional echocardiography in cardiac tamponade: experience of 110 consecutive patients. Eur J Echocardiogr 2000;1(1):6671.
84.Ball, JB, Morrison, WL: Cardiac tamponade. Postgrad Med J 1997;73(857):141–5.
85.Bishop, LH Jr, Estes, EH Jr, McIntosh, HD: The electrocardiogram as a safeguard in pericardiocentesis. JAMA 1956;162(4):264–5.
86.Buzaid, AC, Garewal, HS, Greenberg, BR: Managing malignant pericardial effusion. West J Med 1989;150(2):174–9.
87.Hingorani, AD, Bloomberg, TJ: Ultrasound-guided pigtail catheter drainage of malignant pericardial effusions. Clin Radiol 1995;50(1):1519.
88.Krikorian, JG, Hancock, EW: Pericardiocentesis. Am J Med 1978;65(5):808–14.
89.Suehiro, S, Hattori, K, Shibata, T, et al.: Echocardiography-guided pericardiocentesis with a needle attached to a probe. Ann Thorac Surg 1996;61(2):741–2.
90.Tsang, TS, Enriquez-Sarano, M, Freeman, WK, et al.: Consecutive 1127 therapeutic echocardiographically guided pericardiocenteses: clinical profile, practice patterns, and outcomes spanning 21 years. Mayo Clin Proc 2002;77(5):429–36.
91.Tsang, TS, El-Najdawi, EK, Seward, JB, et al.: Percutaneous echocardiographically guided pericardiocentesis in pediatric patients: evaluation of safety and efficacy. J Am Soc Echocardiogr 1998;11(11):1072–7.
92.Callahan, JA, Seward, JB, Tajik, AJ: Cardiac tamponade: pericardiocentesis directed by two-dimensional echocardiography. Mayo Clin Proc 1985;60(5):344–7.
93.Tsang, TS, Freeman, WK, Sinak, LJ, Seward, JB: Echocardiographically guided pericardiocentesis: evolution and state-of-the-art technique. Mayo Clin Proc 1998;73(7):647–52.
94.Appleton, CP, Hatle, LK, Popp, RL: Cardiac tamponade and pericardial effusion: respiratory variation in transvalvular flow velocities studied by Doppler echocardiography. J Am Coll Cardiol 1988;11(5):1020–30.
95.Armstrong, WF, Schilt, BF, Helper, DJ, et al.: Diastolic collapse of the right ventricle with cardiac tamponade: an echocardiographic study. Circulation 1982;65(7):1491–6.
96.Burstow, DJ, Oh, JK, Bailey, KR, et al.: Cardiac tamponade: characteristic Doppler observations. Mayo Clin Proc 1989;64(3):312–24.
97.Feigenbaum, H, Zaky, A, Grabhorn, LL: Cardiac motion in patients with pericardial effusion: a study using reflected ultrasound. Circulation 1966;34(4):611–19.
98.Kronzon, I, Cohen, ML, Winer, HE: Diastolic atrial compression: a sensitive echocardiographic sign of cardiac tamponade. J Am Coll Cardiol 1983;2(4):770–5.
99.Tsang, TS, Seward, JB, Barnes, ME, et al.: Outcomes of primary and secondary treatment of pericardial effusion in patients with malignancy. Mayo Clin Proc 2000;75(3):248–53.
100.Tsang, TS, Barnes, ME, Hayes, SN, et al.: Clinical and echocardiographic characteristics of significant pericardial effusions following cardiothoracic surgery and outcomes of echo-guided pericardiocentesis for management: Mayo Clinic experience, 1979–1998. Chest 1999;116(2):322–31.
101.Im, SH, Lee, SC, Park, YB, et al.: Feasibility of sonography for intra-articular injections in the knee through a medial patellar portal. J Ultrasound Med 2009;23(11):1465–70.
102.Cunnington, J, Marshall, N, Hide, G, et al.: A randomized, double-blind, controlled study of ultrasound-guided corticosteroid injection into the joint of patients with inflammatory arthritis. Arthritis Rheum 2010;62(7):1862–9.
103.Raza, K, Lee, CY, Pilling, D, et al.: Ultrasound guidance allows accurate needle placement and aspiration from small joints in patients with early inflammatory arthritis. Rheumatology 2003;42(8):976–9.
104.Sibbitt, W, Kettwich, L, Band, P, et al.: Does ultrasound guidance improve the outcomes of arthrocentesis and corticosteroid injections of the knee? Scand J Rheumatol 2012;41(1):6672.
105.Wiler, JL, Constantino, TG, Filippone, L, et al.: Comparison of ultrasound-guided and standard landmark techniques for knee arthrocentesis. J Emerg Med 2010;39(1):7682.
106.Sibbitt, WL, Peisajovich, A, Michael, AA, et al.: Does sonographic needle guidance affect the clinical outcome of intraarticular injections? J Rheumatol 2009;36(9):18921902.
107.Soh, E, Li, W, Ong, KO, et al.: Image-guided versus blind corticosteroid injections in adults with shoulder pain: a systematic review. BMC Musculoskelet Disord 2011;12:137.