Skip to main content
×
×
Home

Transthoracic three-dimensional echocardiography prior to closure of atrial septal defects in children

  • Philippe Acar (a1), Daniel Roux (a1), Yves Dulac (a1), Pierre Rougé (a1) and Yacine Aggoun (a1)...
Abstract

Aims: Our aims were to use transthoracic three-dimensional echocardiography to assess the morphology of atrial septal defects in children prior to closure, and to compare the three-dimensional echocardiographic data with transcatheter and surgical findings. Methods and results:We used transthoracic three-dimensional echocardiography in 62 consecutive patients, aged from 2 to 18 years, with atrial septal defects, measuring the maximal diameter and the extent of the rims. Subsequent to the study, we referred 42 patients for transcatheter closure, the rims being measured at greater than 4 mm. We found a good correlation between the maximal diameter of the defect as measured at transthoracic three-dimensional echocardiography and using a balloon (y = 3.45 − 0.73x; r = 0.78; p < 0.0001), the mean difference between the measurements being 2.4 ± 2.8 mm. Successful closure with the Amplatzer septal occluder, having a mean size of 22 ± 4 mm, was achieved in 95% of the patients. Of the original cohort, 20 patients were referred for surgical closure. In these patients, the inferior rim had been deemed insufficient in 5, the postero-superior rim in 6, and the postero-inferior rim in 9. Complete agreement was found when the deficiency of the rim as judged using transthoracic three-dimensional echocardiography was compared with intraoperative findings. The correlation between measurements of the deficiency of the rim achieved by transthoracic three-dimensional echocardiography and at surgery was excellent (y = 0.2 + 0.98x; r = 0.93; p < 0.0001), the mean difference between the measurements being no more than 0.6 ± 0.4 mm. Conclusions: Transthoracic three-dimensional echocardiography proved accurate in measuring the maximal diameter and rims of atrial septal defects within the oval fossa. This non-invasive method will be valuable in selecting children for transcatheter or surgical closure of such defects.

Copyright
Corresponding author
Correspondence to: Dr Philippe Acar, Cardiologie Pédiatrique, Hôpital des Enfants, 330 av de Grande-Bretagne, 31026 Toulouse, France. Tel: 05 34 55 87 15; Fax: 05 34 55 86 00; E-mail: acar.p@chu-toulouse.fr
References
Hide All

References

Berger F, Ewert P, Bjornstad PG, et al. Transcatheter closure as standard treatment for most interatrial defects: experience in 200 patients with the Amplatzer Septal Occluder. Cardiol Young 1999; 9: 468473.
Losay J, Petit J, Lambert V, et al. Percutaneous with Amplatzer device is a safe and efficient alternative to surgery in adults with large atrial septal defects. Am Heart J 2001; 142: 544548.
Chan KC, Godman MJ, Walsh K, Wilson N, Redington A, Gibbs JL. Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience. Heart 1999; 82: 300306.
Mehta R, Helmcke F, Nanda NC, Pinheiro L, Samdarshi TE, Shah VK. Uses and limitations of transthoracic echocardiography in the assessment of atrial septal defect in adults. Am J Cardiol 1991; 67: 288294.
Godart F, Rey C, Francart C, Jarrar M, Vaksmann G. Two-dimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon-stretched diameter. Am J Cardiol 1993; 72: 10951097.
Faletra F, Scarpini S, Moreo A, et al. Color Doppler echocardiographic assessment of atrial septal defect size: correlation with surgical measurements. J Am Soc Echocardiogr 1991; 4: 429434.
Hellenbrand WE, Fahey JT, McFowan FX, Weltin GG, Kleinman CS. Transesophageal echocardiographic guidance of transcatheter closure of atrial septal defect. Am J Cardiol 1990; 66: 207213.
Rao PS, Langhough R, Beekman RH, Lloyd TR, Sideris EB. Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusion. Am Heart J 1992; 124: 172175.
Acar P, Laskari C, Rhodes J, Pandian NG, Warner K, Marx G. Determinants of mitral regurgitation after atrioventricular septal defect surgery: a three-dimensional echocardiographic study. Am J Cardiol 1999; 83: 745749.
Magni G, Cao QL, Sugeng L, et al. Volume-rendered three-dimensional echocardiographic determination of the size, shape, and position of atrial septal defects: validation in an in vitro model. Am Heart J 1996; 132: 376381.
Acar P, Saliba Z, Bonhoeffer P, et al. Influence of atrial septal defect anatomy in patient selection and assessment of closure by the CardioSEAL device: a three-dimensional transesophageal echocardiography. Eur Heart J 2000; 21: 573581.
Lange A, Walayat M, Turnbull CM, et al. Assessment of atrial septal defect morphology by transthoracic three dimensional echocardiography using standard grey scale and Doppler myocardial imaging techniques: comparison with magnetic resonance imaging and intraoperative findings. Heart 1997; 78: 382389.
Acar P, Maunoury C, Antonietti T, Bonnet D, Sidi D, Kachaner J. Left ventricular ejection fraction in children measured by three-dimensional echocardiography using a new transthoracic integrated 3D-probe. Eur Heart J 1998; 19: 15831588.
Acar P, Saliba Z, Bonhoeffer P, Sidi D, Kachaner J. Assessment of the geometric profile of the Amplatzer and Cardioseal occluders by three-dimensional echocardiograpy. Heart 2001; 85: 451453.
Gu X, Han YM, Berry J, Urness M, Amplatz K. A new technique for sizing of atrial septal defects. Catheter Cardiovasc Interv 1999; 46: 5157.
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307310.
Magni G, Hijazi Z, Pandian NG, et al. Two- and three-dimensional transesophageal echocardiography in patient selection and assessment of atrial septal defect closure by the new DAS-Angel wings device. Circulation 1997; 96: 17221728.
Marx GR, Fulton DR, Pandian NG, et al. Delineation of site, relative size and dynamic geometry of atrial septal defect by real-time three-dimensional echocardiography. J Am Coll Cardiol 1995; 25: 482490.
Franke A, Kühl HP, Rulands D, et al. Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography. Circulation 1997; 96 (suppl II): II-323327.
Acar P, Jones M, Shiota T, et al. Quantitative assessment of chronic aortic regurgitation using three-dimensional echocardiographic reconstruction: comparison with electromagnetic flow-meter measurements. J Am Soc Echocardiogr 1999; 12: 138148.
De Simone R, Glombitza G, Vahl CF, Albers J, Meinzer HP, Hagl S. Three-dimensional color Doppler: a clinical study in patients with mitral regurgitation. J Am Coll Cardiol 1999; 33: 16461654.
Chauvel C, Bogino E, Clerc P, et al. Usefulness of three-dimensional echocardiography for the evaluation of mitral valve prolapse: an intraoperative study. J Heart Valve Dis 2000; 9: 341349.
Acar P, Saliba Z, Sidi D, Kachaner J. New insight into the single ventricular function after total cavopulmonary connection: a three-dimensional echocardiographic study. Cardiol Young 2000; 10: 8389.
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Cardiology in the Young
  • ISSN: 1047-9511
  • EISSN: 1467-1107
  • URL: /core/journals/cardiology-in-the-young
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords:

Metrics

Full text views

Total number of HTML views: 1
Total number of PDF views: 6 *
Loading metrics...

Abstract views

Total abstract views: 64 *
Loading metrics...

* Views captured on Cambridge Core between September 2016 - 13th June 2018. This data will be updated every 24 hours.