SummaryBackground and objective

In emergency trauma situations, manual in-line stabilization of the cervical spine is recommended to reduce cervical spine movement during intubation. The aim of this study was to compare the effect of manual in-line stabilization during different intubation techniques on three-dimensional cervical spine movements and times to intubation.


Forty-eight subjects without any history of trauma, inflammatory or degenerative disorder of the cervical spine were randomly grouped, regardless of gender or age. All underwent elective surgery under general anaesthesia. Under manual in-line stabilization, laryngeal intubation with Macintosh laryngoscope, intubating laryngeal mask airway, fibre-endoscopic oral intubation and fibre-endoscopic nasal intubation was performed. During the intubation process, cervical three-dimensional motion was detected by an ultrasound real-time motion analysis system and intubation times were measured.


Cervical spine range in the extension/flexion direction of orolaryngeal intubation with Macintosh (17.57 ± 8.23°) showed significantly more movement than using the intubating laryngeal mask airway (4.60 ± 1.51°) and fibreoptic procedures. Intubating laryngeal mask airway was significantly different than the fibreoptic intubation techniques. There was also a significant difference between oral (3.61 ± 2.25°) nasal and (5.88 ± 3.11°) fibreoptic intubation. Times to intubation all differed significantly (P < 0.05) for the Macintosh laryngoscope (27.25 ± 8.56 s) and for the intubating laryngeal mask airway (16.5 ± 9.76 s). Fibreendoscopic laryngoscopic oral (52.91 ± 56.27 s) and nasal (82.32 ± 54.06 s) intubation resulted in further prolongation of the times to intubation.


The intubating laryngeal mask airway with manual in-line stabilization is a potentially useful adjunct to intubation of patients with potential cervical spine injury, if there are no contraindications to these methods. These results predict that fibreoptic procedures may be a safe instrument for airway management in patients with potential cervical spine injuries; however, the main disadvantages are the longer intubation times.

Corresponding author
Correspondence to: Erol Gercek, Clinic of Trauma Surgery, Johannes Gutenberg-University of Mainz, Langenbeckstrasse 1, 55131 Mainz, Germany. E-mail:; Tel: +496131172845; Fax: +496131176687
Linked references
Hide All

This list contains references from the content that can be linked to their source. For a full set of references and notes please see the PDF or HTML where available.

1.E Crosby . Airway management after upper cervical spine injury: what have we learned? Can J Anaesth 2002; 49: 733744.

2.RH Hastings , SD Kelley . Neurologic deterioration associated with airway management in a cervical spine-injured patient. Anesthesiology 1993; 78: 580583.

3.IG Stiell , CM Clement , RD McKnight . The Canadian C-spine rule versus the NEXUS low-risk criteria in patients with trauma. N Engl J Med 2003; 349: 25102518.

4.SR Mallampati , SP Gatt , LD Gugino . A clinical sign to predict difficult tracheal intubation: a prospective study. Can Anaesth Soc J 1985; 32: 429434.

5.RS Cormack , J Lehane . Difficult tracheal intubation in obstetrics. Anaesthesia 1984; 39: 11051111.

6.DC Reid , R Henderson , L Saboe , JD Miller . Etiology and clinical course of missed spine fractures. J Trauma 1987; 27: 980986.

8.JL Benumof . Laryngeal mask airway and the ASA difficult airway algorithm. Anesthesiology 1996; 84: 686699.

9.J Brimacombe . The advantages of the LMA over the tracheal tube or facemask: a meta-analysis. Can J Anaesth 1995; 42: 10171023.

10.B Waltl , M Melischek , C Schuschnig . Tracheal intubation and cervical spine excursion: direct laryngoscopy vs. intubating laryngeal mask. Anaesthesia 2001; 56: 221226.

11.ET Crosby . Airway management in adults after cervical spine trauma. Anesthesiology 2006; 104: 12931318.

13.J Gilliam , D Brunt , M MacMillan , RE Kinard , WJ Montgomery . Relationship of the pelvic angle to the sacral angle: measurement of clinical reliability and validity. J Orthop Sports Phys Ther 1994; 20: 193199.

14.NM Gajraj , DP Chason , VE Shearer . Comparison of the Belscope with the Macintosh laryngoscope. Br J Anaesth 1994; 72: 610611.

15.RH Hastings , AC Vigil , R Hanna , BY Yang , DJ Sartoris . Cervical spine movement during laryngoscopy with the Bullard, Macintosh, and Miller laryngoscopes. Anesthesiology 1995; 82: 859869.

16.J Brimacombe , C Keller , KH Kunzel . Cervical spine motion during airway management: a cinefluoroscopic study of the posteriorly destabilized third cervical vertebrae in human cadavers. Anesth Analg 2000; 91: 12741278.

17.M Hauswald , DP Sklar , D Tandberg , JF Garcia . Cervical spine movement during airway management: cinefluoroscopic appraisal in human cadavers. Am J Emerg Med 1991; 9: 535538.

18.A Sahin , MA Salman , IA Erden , U Aypar . Upper cervical vertebrae movement during intubating laryngeal mask, fibreoptic and direct laryngoscopy: a video-fluoroscopic study. Eur J Anaesthesiol 2004; 21: 819823.

19.PD Sawin , MM Todd , VC Traynelis . Cervical spine motion with direct laryngoscopy and orotracheal intubation, an in vivo cinefluoroscopic study of subjects without cervical abnormality. Anesthesiology 1996; 85: 2636.

20.P McClure , S Siegler , R Nobilini . Three-dimensional flexibility characteristics of the human cervical spine in vivo. Spine 1998; 23: 216223.

21.N Bogduk , S Mercer . Biomechanics of the cervical spine. I: normal kinematics. Clin Biomech (Bristol, Avon) 2000; 15: 633648.

22.A Holmes , C Wang , ZH Han , GT Dang . The range and nature of flexion-extension motion in the cervical spine. Spine 1994; 19: 25052510.

23.J Dvorak , JA Antinnes , M Panjabi , D Loustalot , M Bonomo . Age and gender related normal motion of the cervical spine. Spine 1992; 17: S393S398.

24.WH Castro , A Sautmann , M Schilgen , M Sautmann . Noninvasive three-dimensional analysis of cervical spine motion in normal subjects in relation to age and sex. An experimental examination. Spine 2000; 25: 443449.

25.AF Mannion , GN Klein , J Dvorak , C Lanz . Range of global motion of the cervical spine: intraindividual reliability and the influence of measurement device. Eur Spine J 2000; 9: 379385.

27.S Manoach , L Paladino . Manual in-line stabilization for acute airway management of suspected cervical spine injury: historical review and current questions. Ann Emerg Med 2007.

28.AD McLeod , I Calder . Spinal cord injury and direct laryngoscopy – the legend lives on. Br J Anaesth 2000; 84: 705709.

29.M Richter , HJ Wilke , P Kluger , L Claes , W Puhl . Load-displacement properties of the normal and injured lower cervical spine in vitro. Eur Spine J 2000; 9: 104108.

32.RH Hastings , PR Wood . Head extension and laryngeal view during laryngoscopy with cervical spine stabilization maneuvers. Anesthesiology 1994; 80: 825831.

33.WF Donaldson III, JD Towers , A Doctor , A Brand , VP Donaldson . A methodology to evaluate motion of the unstable spine during intubation techniques. Spine 1993; 18: 20202023.

34.TG Majernick , R Bieniek , JB Houston , HG Hughes . Cervical spine movement during orotracheal intubation. Ann Emerg Med 1986; 15: 417420.

35.S Kihara , S Watanabe , J Brimacombe . Segmental cervical spine movement with the intubating laryngeal mask during manual in-line stabilization in patients with cervical pathology undergoing cervical spine surgery. Anesth Analg 2000; 91: 195200.

36.AD Watts , AW Gelb , DB Bach , DM Pelz . Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury. Anesthesiology 1997; 87: 13351342.

37.BM Wahlen , E Gercek . Three-dimensional cervical spine movement during intubation using the Macintosh and Bullard laryngoscopes, the bonfils fibrescope and the intubating laryngeal mask airway. Eur J Anaesthesiol 2004; 21: 907913.

38.JP Nolan , ME Wilson . Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie. Anaesthesia 1993; 48: 630633.

Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

European Journal of Anaesthesiology
  • ISSN: 0265-0215
  • EISSN: 1365-2346
  • URL: /core/journals/european-journal-of-anaesthesiology
Please enter your name
Please enter a valid email address
Who would you like to send this to? *