Hostname: page-component-76fb5796d-2lccl Total loading time: 0 Render date: 2024-04-25T23:07:24.428Z Has data issue: false hasContentIssue false

Electronic Surveillance for Healthcare-Associated Central Line—Associated Bloodstream Infections Outside the Intensive Care Unit

Published online by Cambridge University Press:  02 January 2015

Keith F. Woeltje*
Affiliation:
Division of Infectious Diseases, Department of Internal Medicine, Washington University School of Medicine, St. Louis, Missouri Center for Clinical Excellence, BJC HealthCare, St. Louis, Missouri
Kathleen M. McMullen
Affiliation:
Infection Prevention Department, Barnes-Jewish Hospital, St. Louis, Missouri
Anne M. Butler
Affiliation:
Department of Epidemiology, University of North Carolina, Chapel Hill, North Carolina
Ashleigh J. Goris
Affiliation:
Progress West Health Center, O'Fallon, Missouri
Joshua A. Doherty
Affiliation:
Center for Clinical Excellence, BJC HealthCare, St. Louis, Missouri
*
Division of Infectious Diseases, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8051, St. Louis, MO 63110 (kwoeltje@dom.wustl.edu)

Abstract

Background.

Manual surveillance for central line-associated bloodstream infections (CLABSIs) by infection prevention practitioners is time-consuming and often limited to intensive care units (ICUs). An automated surveillance system using existing databases with patient-level variables and microbiology data was investigated.

Methods.

Patients with a positive blood culture in 4 non-ICU wards at Barnes-Jewish Hospital between July 1, 2005, and December 31, 2006, were evaluated. CLABSI determination for these patients was made via 2 sources; a manual chart review and an automated review from electronically available data. Agreement between these 2 sources was used to develop the best-fit electronic algorithm that used a set of rules to identify a CLABSI. Sensitivity, specificity, predictive values, and Pearson's correlation were calculated for the various rule sets, using manual chart review as the reference standard.

Results.

During the study period, 391 positive blood cultures from 331 patients were evaluated. Eighty-five (22%) of these were confirmed to be CLABSI by manual chart review. The best-fit model included presence of a catheter, blood culture positive for known pathogen or blood culture with a common skin contaminant confirmed by a second positive culture and the presence of fever, and no positive cultures with the same organism from another sterile site. The best-performing rule set had an overall sensitivity of 95.2%, specificity of 97.5%, positive predictive value of 90%, and negative predictive value of 99.2% compared with intensive manual surveillance.

Conclusions.

Although CLABSIs were slightly overpredicted by electronic surveillance compared with manual chart review, the method offers the possibility of performing acceptably good surveillance in areas where resources do not allow for traditional manual surveillance.

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Haley, RW, Culver, DH, White, JW, et al. The efficacy of infection surveillance and control programs in preventing nosocomial infections in US hospitals. Am J Epidemiol 1985;121:182205.Google Scholar
2.Jarvis, WR. Benchmarking for prevention: the Centers for Disease Control and Prevention's National Nosocomial Infections Surveillance (NNIS) system experience. Infection 2003;31(suppl 2):4448.Google ScholarPubMed
3.Marschall, J, Leone, C, Jones, M, Nihill, D, Fräser, VJ, Warren, DK. Catheter-associated bloodstream infections in general medical patients outside the intensive care unit: a surveillance study. Infect Control Hosp Epidemiol 2007;28:905909.Google Scholar
4.Edwards, JR, Peterson, KD, Mu, Y, et al. National Healthcare Safety Network (NHSN) report: data summary for 2006 through 2008, issued December 2009. Am J Infect Control 2009;37: 783805.CrossRefGoogle ScholarPubMed
5.Climo, M, Diekema, D, Warren, DK, et al. Prevalence of the use of central venous access devices within and outside of the intensive care unit: results of a survey among hospitals in the Prevention Epicenter Program of the Centers for Disease Control and Prevention. Infect Control Hosp Epidemiol 2003;24: 942945.Google Scholar
6.Trick, WE, Zagorski, BM, Tokars, JI, et al. Computer algorithms to detect bloodstream infections. Emerg Infect Dis 2004;10:16121620.CrossRefGoogle ScholarPubMed
7.Woeltje, KF, Butler, AM, Goris, AJ, et al. Automated surveillance for central line-associated bloodstream infection in intensive care units. Infect Control Hosp Epidemiol 2008;29:842846.Google Scholar
8.Kahn, MG, Steib, SA, Fräser, VJ, Dunagan, WC. An expert system for culture-based infection control surveillance. Proc Annu Symp Comput Appl Med Care 1993;171175.Google ScholarPubMed
9.Horan, TC, Andrus, M, Dudeck, MA. CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control 2008;36:309332.Google Scholar
10.Centers for Disease Control and Prevention. National Healthcare Safety Network Patient Safety Manual: Central Line-Associated Bloodstream Infection (CLABSI) Event. http://www.cdc.gov/nhsn/PDFs/pscManual/4PSC_CLABScurrent.pdf. Accessed December 31, 2010.Google Scholar
11.Yokoe, DS, Anderson, J, Chambers, R, et al. Simplified surveillance for nosocomial bloodstream infections. Infect Control Hosp Epidemiol 1998;19:657660.Google Scholar
12.Leth, RA, Moller, JK. Surveillance of hospital-acquired infections based on electronic hospital registries. J Hosp Infect 2006;62:7179.CrossRefGoogle ScholarPubMed
13.Wang, SJ, Kuperman, GJ, Ohno-Machado, L, Onderdonk, A, Sandige, H, Bates, DW. Using electronic data to predict the probability of true bacteremia from positive blood cultures. Proc AMIA Symp 2000;893897.Google ScholarPubMed
14.Graham, PL III, San Gabriel, P, Lutwick, S, Haas, J, Saiman, L. Validation of a multicenter computer-based surveillance system for hospital-acquired bloodstream infections in neonatal intensive care departments. Am J Infect Control 2004;32:232234.CrossRefGoogle ScholarPubMed
15.Wenzel, RP, Osterman, CA, Hunting, KJ. Hospital-acquired infections. II. Infection rates by site, service and common procedures in a university hospital. Am J Epidemiol 1976;104:645651.CrossRefGoogle ScholarPubMed
16.Haley, RW, Schaberg, DR, McClish, DK, et al. The accuracy of retrospective chart review in measuring nosocomial infection rates: results of validation studies in pilot hospitals. Am J Epidemiol 1980;111:516533.CrossRefGoogle ScholarPubMed
17.Burke, JP. Infection control: a problem for patient safety. N Engl J Med 2003;348:651656.CrossRefGoogle ScholarPubMed
18.Lin, MY, Hota, B, Khan, YM, et al; for the CDC Prevention Epicenter Program. Quality of traditional surveillance for public reporting of nosocomial bloodstream infection rates. JAMA 2010;304:20352041.CrossRefGoogle ScholarPubMed
19.Emori, TG, Edwards, JR, Culver, DH, et al. Accuracy of reporting nosocomial infections in intensive-care-unit patients to the National Nosocomial Infections Surveillance system: a pilot study. Infect Control Hosp Epidemiol 1998;19:308316.Google Scholar
20.Niedner, MF; for the 2008 National Association of Children's Hospitals and Related Institutions Pediatric Intensive Care Unit Patient Care FOCUS Group. The harder you look, the more you find: catheter-associated bloodstream infection surveillance variability. Am J Infect Control 2010;38:585595.CrossRefGoogle ScholarPubMed
21.Backman, LA, Melchreit, R, Rodriguez, R. Validation of the surveillance and reporting of central line-associated bloodstream infection data to a state health department. Am J Infect Control 2010;38:832838.Google Scholar