Nosocomial Serratia marcescens Outbreak in Osaka, Japan, From 1999 to 2000

  • Hiroshi Takahashi (a1) (a2), Michael H. Kramer (a1), Yoshinori Yasui (a3), Hayato Fujii (a1), Katsumi Nakase (a1), Kazunori Ikeda (a3), Tatsuya Imai (a3), Akiko Okazawa (a3), Tomoyuki Tanaka (a4), Takaaki Ohyama (a1) (a2) and Nobuhiko Okabe (a2)...
Abstract
AbstractObjectives:

To investigate and control an outbreak of bloodstream infections (BSIs) caused by Serratia marcescens and to identify risk factors for respiratory colonization or infection with S. marcescens.

Design:

Epidemiologic investigation, including review of medical and laboratory records, procedural investigations, pulsed-field gel electrophoresis (PFGE) typing of environmental and patient isolates, statistical study, and recommendation of control measures.

Patients and Setting:

All patients admitted to a 380-bed, secondary-care hospital in Osaka Prefecture, Japan, from July 1999 through June 2000 (study period).

Results:

Seventy-one patients were colonized or infected with S. marcescens; 3 patients who developed primary BSIs on the same ward within 5 days in June 2000 had isolates with indistinguishable PFGE patterns and indwelling intravenous catheters for more than 5 days. On multivariate analysis, among 36 case-patients with positive sputum specimens and 95 control-patients, being bedridden (odds ratio [OR], 15.91; 95% confidence interval [CI95], 4.17-60.77), receiving mechanical ventilation (OR, 7.86; CI95, 2.27-27.16), being older than 80 years (OR, 3.12; CI95, 1.05-9.27), and receiving oral cleaning care (OR 3.10; CI95, 1-9.58) were significant risk factors. S. marcescens was isolated from the fluid tanks of three nebulizers and a liquid soap dispenser. The hospital did not have written infection control standards, and many infection control practices were found to be inadequate (eg, respiratory equipment was used without disinfection between patients).

Conclusions:

Poor hospital hygiene and the lack of standard infection control measures contributed to infections hospital-wide. Recommendations to the hospital included adoption of written infection control policies.

Copyright
Corresponding author
Infectious Disease Surveillance Center, National Institute of Infectious Diseases, Toyama 1-23-1, Shinjuku-ku, Tokyo 162-8640, Japan
Linked references
Hide All

This list contains references from the content that can be linked to their source. For a full set of references and notes please see the PDF or HTML where available.

1. RP Wheat , A Zuckerman , LA Rantz . Infection due to chromobacteria: report of eleven cases. Arch Intern Med 1951;88:461466.

2. HA Cabrera . An outbreak of Serratia marcescens and its control. Arch Intern Med 1969;123:650655.

3. DG Maki , WT Martin . Nationwide epidemie of septicemia caused by contaminated infusion products: IV. Growth of microbial pathogens in fluids for intravenous infusion. J Infect Dis 1975;131:267272.

5. LK Archibald , A Corl , B Shah , et al.Serratia marcescens outbreak associated with extrinsic contamination of 1% chlorxylenol soap. Infect Control Hosp Epidemiol 1997;18:704709.

7. C Bosi , A Davin-Regli , R Charrel , B Rocca , D Monnet , C Bollet . Serratia marcescens nosocomial outbreak due to contamination of hexetidine solution. J Hosp Infect 1996;33:217224.

8. P Vigeant , V Loo , C Bertrand , et al.An outbreak of Serratia marcescens infections related to contaminated chlorhexidine. Infect Control Hosp Epidemiol 1999;19:791794.

9. VL Yu . Serratia marcescens: historical perspective and clinical review. N Engl J Med 1979;300:887893.

10. SJ Sokalski , MA Jewell , AC Asmus-Shillington , J Mucahy , J Segreti . An outbreak of Serratia marcescens in 14 adult cardiac surgical patients associated with 12-lead electrocardiogram bulbs. Arch Intern Med 1992;152:841844.

11. CMJE Vandenbroucke-Grauls , ACM Baars , MR Visser , PF Hulstaert , J Verhoef . An outbreak of Serratia marcescens traced to a contaminated bronchoscope. J Hosp Infect 1993;23:263270.

12. CV Sanders , JP Luby , WG Johanson , JA Barnett , JP Sanford . Serratia marcescens infections from inhalation therapy medications: nosocomial outbreak. Ann Intern Med 1970;73:1521.

13. RE Ringrose , B McKown , FG Felton , BO Barclay , HG Muchmore , R Rhodes . A hospital outbreak of Serratia marcescens associated with ultrasonic nebulizers. Ann Intern Med 1968;69:719729.

14. ER Rhoades , R Ringrose , JA Mohr , L Brooks , BA McKown , F Felton . Contamination of ultrasonic nebulization equipment with gram negative bacteria. Arch Intern Med 1971;127:228232.

18.Centers for Disease Control and Prevention. National Nosocomial Infection Surveillance (NNIS) report: data summary from October 1986-April 1996. Am J Infect Control 1996;24:380388.

19. LA Grohskopf , VR Roth , DR Feikin , et al.Serratia liquefaciens blood-stream infections from contamination of epoetin alfa at a hemodialysis center. N Engl J Med 2001;344:14911497.

Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Infection Control & Hospital Epidemiology
  • ISSN: 0899-823X
  • EISSN: 1559-6834
  • URL: /core/journals/infection-control-and-hospital-epidemiology
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 1 *
Loading metrics...

Abstract views

Total abstract views: 43 *
Loading metrics...

* Views captured on Cambridge Core between September 2016 - 21st August 2017. This data will be updated every 24 hours.