Skip to main content
    • Aa
    • Aa
  • Get access
    Check if you have access via personal or institutional login
  • Cited by 1
  • Cited by
    This article has been cited by the following publications. This list is generated based on data provided by CrossRef.

    Martelli, Nicolas van den Brink, Hélène and Borget, Isabelle 2016. New French Coverage with Evidence Development for Innovative Medical Devices: Improvements and Unresolved Issues. Value in Health, Vol. 19, Issue. 1, p. 17.

  • International Journal of Technology Assessment in Health Care, Volume 29, Issue 2
  • April 2013, pp. 123-130


  • Leslie Pibouleau (a1) and Sylvie Chevret (a1)
  • DOI:
  • Published online: 19 April 2013

Objectives: The aim of this study was to propose a statistical model that takes into account clinical data on earlier versions when evaluating the latest version of an implantable medical device (IMD).

Methods: We compared the performances of a Bayesian three-level hierarchical meta-analysis model with those of a Bayesian random-effects model through a simulation study. Posterior mean estimates of the success rate for each IMD version were computed as well as the probability that the latest version improved in effectiveness. Models were compared using the Deviance Information Criterion (DIC), the estimated bias and the standard deviation of the mean success rates. Sensitivity analyses to the choice of the priors were performed. These methods were applied to the evaluation of an intracranial stent used to treat wide-necked aneurysms.

Results: When IMD versions did not differ in effectiveness, the best-fitting model was the random-effects model. By contrast, when there was a version effect, the hierarchical model was selected in more than 95 percent of the cases. It provided precise estimations of success rates of each IMD version and allowed detecting an improvement in effectiveness of the latest version, with a low influence of the choice of the priors. No evidence of benefit from the latest version of the intracranial stent was found.

Conclusions: In the setting of IMD assessment, comparison of DIC between the two proposed models appeared useful for detecting version effects. In that case, Bayesian hierarchical meta-analysis model may help the decision maker by providing useful information on the latest version of IMD compared with the previous versions.

Linked references
Hide All

This list contains references from the content that can be linked to their source. For a full set of references and notes please see the PDF or HTML where available.

1.D Cohen , M Billingsley . Europeans are left to their own devices. BMJ. 2011;342:d2748.

2.GD Curfman , RF Redberg . Medical devices–balancing regulation and innovation. N Engl J Med. 2011;365:975977.

3.A Sedrakyan , D Marinac-Dabic , SL Normand , A Mushlin , T Gross . A framework for evidence evaluation and methodological issues in implantable device studies. Med Care. 2010;48 (Suppl):S121S128.

4.AJ Sutton , KR Abrams . Bayesian methods in meta-analysis and evidence synthesis. Stat Methods Med Res. 2001;10:277303.

5.L Pibouleau , S Chevret . Bayesian statistical method was underused despite its advantages in the assessment of implantable medical devices. J Clin Epidemiol. 2010;64:270279.

6.CE McCarron , EM Pullenayegum , L Thabane , R Goeree , JE Tarride . The importance of adjusting for potential confounders in Bayesian hierarchical models synthesising evidence from randomised and non-randomised studies: An application comparing treatments for abdominal aortic aneurysms. BMC Med Res Methodol. 2010;10:64.

7.TC Prevost , KR Abrams , DR Jones . Hierarchical models in generalized synthesis of evidence: An example based on studies of breast cancer screening. Stat Med. 2000;19:33593376.

8.RP Benitez , MT Silva , J Klem , E Veznedaroglu , RH Rosenwasser . Endovascular occlusion of wide-necked aneurysms with a new intracranial microstent (Neuroform) and detachable coils. Neurosurgery. 2004;54:13591367.

9.A Biondi , V Janardhan , JM Katz , et al.Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up. Neurosurgery. 2007;61:460468; discussion 468–469.

11.A Gordhan , D Invergo . Stent-assisted aneurysm coil embolization: Safety and efficacy at a low-volume center. Neurol Res. 2011;33:942946.

12.P Jabbour , C Koebbe , E Veznedaroglu , RP Benitez , R Rosenwasser . Stent-assisted coil placement for unruptured cerebral aneurysms. Neurosurg Focus. 2004;17:E10.

13.Y Kadkhodayan , CT Somogyi , DT III Cross , et al.Technical, angiographic and clinical outcomes of Neuroform 1, 2, 2 Treo and 3 devices in stent-assisted coiling of intracranial aneurysms. J Neurointerv Surg. 2012;4:368374.

15.YJ Lee , DJ Kim , SH Suh , et al.Stent-assisted coil embolization of intracranial wide-necked aneurysms. Neuroradiology. 2005;47:680689.

16.G Liang , X Gao , Z Li , X Wei , H Xue . Neuroform stent-assisted coiling of intracranial aneurysms: A 5 year single-center experience and follow-up. Neurol Res. 2010;32:721727.

17.S Sani , KW Jobe , DK Lopes . Treatment of wide-necked cerebral aneurysms with the Neuroform2 Treo stent. A prospective 6-month study. Neurosurg Focus. 2005;18:E4.

18.E Wajnberg , JM de Souza , E Marchiori , EL Gasparetto . Single-center experience with the Neuroform stent for endovascular treatment of wide-necked intracranial aneurysms. Surg Neurol. 2009;72:612619.

19.I Wanke , A Doerfler , S Goericke , et al.Treatment of wide-necked intracranial aneurysms with a self-expanding stent: Mid-term results. Zentralbl Neurochir. 2005;66:163169.

20.A Agresti , BA Coull . Approximate is better than “exact” for interval estimation of binomial proportions. Am Stat. 1998;52:119126.

21.JP Higgins , SG Thompson . Quantifying heterogeneity in a meta-analysis. Stat Med. 2002;21:15391558.

22.TC Smith , DJ Spiegelhalter , A Thomas . Bayesian approaches to random-effects meta-analysis: A comparative study. Stat Med. 1995;14:26852699.

23.DJ Spiegelhalter , KR Abrams , JP Myles . Bayesian approaches to clinical trials and health-care evaluation. New York: Wiley; 2004.

25.D Spiegelhalter , N Best , BP Carlin , A Van der Linde . Bayesian measures of model complexity and fit. J R Statist Soc B. 2002;64:583639.

Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

International Journal of Technology Assessment in Health Care
  • ISSN: 0266-4623
  • EISSN: 1471-6348
  • URL: /core/journals/international-journal-of-technology-assessment-in-health-care
Please enter your name
Please enter a valid email address
Who would you like to send this to? *