Is nasal steroid spray bottle contamination a potential issue in chronic rhinosinusitis?

  • N C-W Tan (a1), A J Drilling (a1), C Jardeleza (a1) and P-J Wormald (a1)

Abstract

Background:

Intranasal steroids are the first line of treatment for chronic rhinosinusitis. Although contamination of adjunctive devices (e.g. irrigation bottles) has been much investigated, little is known about nasal contamination of the metered-dose spray bottles used to deliver intranasal steroids, and the potential influence on disease chronicity.

Methods:

Twenty-five prospectively recruited patients with stable chronic rhinosinusitis underwent microbiological analysis of their nasal vestibule and middle meatus and also of their steroid bottle tip and contents. Additionally, bottle tips were inoculated in vitro with Staphylococcus aureus and various sterilisation techniques tested.

Results:

For 18 of the 25 (72 per cent) patients, both nasal and bottle tip swabs grew either Staphylococcus aureus or coagulase-negative staphylococci. Staphylococcus aureus was cultured from 7 of the 25 (28 per cent) patients, and 5 of these 7 had concomitant bacterial growth from both nose and steroid bottle. Thus, the cross-contamination rate was 71 per cent for Staphylococcus aureus infected patients and 20 per cent overall. Sterilisation was effective with boiling water, ethanol wipes and microwaving, but not with cold water or dishwashing liquid.

Conclusion:

Nasal steroid spray bottle tips can become contaminated with sinonasal cavity bacteria. Simple sterilisation methods can eliminate this contamination. Patient education on this matter should be emphasised.

Copyright

Corresponding author

Address for correspondence: Professor P-J Wormald, Department of Surgery – Otolaryngology, Adelaide Universities, The Queen Elizabeth Hospital, 28 Woodville Road, Woodville, SA, Australia, 5011 E-mail: peterj.wormald@adelaide.edu.au

References

Hide All
1Fokkens, W, Lund, V, Mullol, J. European position paper on rhinosinusitis and nasal polyps 2007. Rhinol Suppl 2007:1136
2Benninger, MS, Ferguson, BJ, Hadley, JA, Hamilos, DL, Jacobs, M, Kennedy, DW et al. Adult chronic rhinosinusitis: definitions, diagnosis, epidemiology, and pathophysiology. Otolaryngol Head Neck Surg 2003;129(suppl 3):S132
3Scadding, GK, Durham, SR, Mirakian, R, Jones, NS, Drake-Lee, AB, Ryan, D et al. BSACI guidelines for the management of rhinosinusitis and nasal polyposis. Clin Exp Allergy 2008;38:260–75
4Rizzi, M, Batra, PS, Hall, G, Citardi, MJ, Lanza, DC. An assessment for the presence of bacterial contamination of Venturi principle atomizers in a clinical setting. Am J Rhinol 2005;19:21–3
5Dubin, MG, White, DR, Melroy, CT, Gergan, MT, Rutala, WA, Senior, BA. Multi-use Venturi nasal atomizer contamination in a clinical rhinologic practice. Am J Rhinol 2004;18:151–6
6Lee, JM, Nayak, JV, Doghramji, LL, Welch, KC, Chiu, AG. Assessing the risk of irrigation bottle and fluid contamination after endoscopic sinus surgery. Am J Rhinol Allergy 2010;24:197–9
7Keen, M, Foreman, A, Wormald, PJ. The clinical significance of nasal irrigation bottle contamination. Laryngoscope 2010;120:2110–14
8Welch, KC, Cohen, MB, Doghramji, LL, Cohen, NA, Chandra, RK, Palmer, JN et al. Clinical correlation between irrigation bottle contamination and clinical outcomes in post-functional endoscopic sinus surgery patients. Am J Rhinol Allergy 2009;23:401–4
9Lewenza, S, Charron-Mazenod, L, Cho, JJ, Mechor, B. Identification of bacterial contaminants in sinus irrigation bottles from chronic rhinosinusitis patients. J Otolaryngol Head Neck Surg 2010;39:458–63
10Singhal, D, Foreman, A, Bardy, JJ, Wormald, PJ. Staphylococcus aureus biofilms: nemesis of endoscopic sinus surgery. Laryngoscope 2011;121:1578–83
11Singhal, D, Psaltis, AJ, Foreman, A, Wormald, PJ. The impact of biofilms on outcomes after endoscopic sinus surgery. Am J Rhinol Allergy 2010;24:169–74
12Plouin-Gaudon, I, Clement, S, Huggler, E, Chaponnier, C, Francois, P, Lew, D et al. Intracellular residency is frequently associated with recurrent Staphylococcus aureus rhinosinusitis. Rhinology 2006;44:249–54
13Jervis-Bardy, J, Foreman, A, Boase, S, Valentine, R, Wormald, PJ. What is the origin of Staphylococcus aureus in the early postoperative sinonasal cavity? Int Forum Allergy Rhinol 2011;1:308–12
14Tan, NC, Foreman, A, Jardeleza, C, Douglas, R, Tran, H, Wormald, PJ. The multiplicity of Staphylococcus aureus in chronic rhinosinusitis: correlating surface biofilm and intracellular residence. Laryngoscope 2012;122:1655–60
15Lanza, DC, Kennedy, DW. Adult rhinosinusitis defined. Otolaryngol Head Neck Surg 1997;117:S17
16Rosenfeld, RM. Hand washing. Otolaryngol Head Neck Surg 2009;141:667–9
17Boyce, JM, Pittet, D. Guideline for Hand Hygiene in Health-Care Settings. Recommendations of the Healthcare Infection Control Practices Advisory Committee and the HIPAC/SHEA/APIC/IDSA Hand Hygiene Task Force. Am J Infect Control 2002;30:S146
18Foreman, A, Jervis-Bardy, J, Wormald, PJ. Do biofilms contribute to the initiation and recalcitrance of chronic rhinosinusitis? Laryngoscope 2011;121:1085–91
19Jervis-Bardy, J, Foreman, A, Field, J, Wormald, PJ. Impaired mucosal healing and infection associated with Staphylococcus aureus after endoscopic sinus surgery. Am J Rhinol Allergy 2009;23:549–52
20Foreman, A, Wormald, PJ. Can bottle design prevent bacterial contamination of nasal irrigation devices? Int Forum Allergy Rhinol 2011;1:303–7
21Spraggs, PD, Hanekom, WH, Mochloulis, G, Joseph, T, Kelsey, MC. The assessment of the risk of cross-infection with a multi-use nasal atomizer. J Hosp Infect 1994;28:315–21
22Bhattacharyya, N, Kepnes, L. Bacterial colonization of nasal steroid inhalers in chronic rhinosinusitis. Am J Rhinol 2002;16:319–21
23Kuehnert, MJ, Kruszon-Moran, D, Hill, HA, McQuillan, G, McAllister, SK, Fosheim, G et al. Prevalence of Staphylococcus aureus nasal colonization in the United States, 2001–2002. J Infect Dis 2006;193:172–9
24Feazel, LM, Robertson, CE, Ramakrishnan, VR, Frank, DN. Microbiome complexity and Staphylococcus aureus in chronic rhinosinusitis. Laryngoscope 2012;122:467–72
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

The Journal of Laryngology & Otology
  • ISSN: 0022-2151
  • EISSN: 1748-5460
  • URL: /core/journals/journal-of-laryngology-and-otology
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords

Metrics

Altmetric attention score

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed