Behavior of Au Species in Au/Fe2O3 Catalysts Characterized by Novel In Situ Heating Techniques and Aberration-Corrected STEM Imaging

  • Lawrence F. Allard (a1), Maria Flytzani-Stephanopoulos (a2) and Steven H. Overbury (a1)
Abstract

The recent advent of a novel design of in situ heating technology for electron microscopes has permitted unprecedented control of elevated temperature studies of catalytic materials, particularly when coupled with the sub-Ångström imaging performance of a modern aberration-corrected scanning transmission electron microscope (STEM). Using micro-electro-mechanical-systems (MEMS)-based Aduro™ heating chips from Protochips, Inc. (Raleigh, NC, USA) allows nearly instantaneous heating and cooling of catalyst powders, avoiding effects of temperature ramping as experienced with standard heating stages. The heating technology also provides stable operation limited only by the inherent drift in the microscope stage, thus allowing full image resolution to be achieved even at elevated temperatures. The present study details the use of both the high X-Y spatial resolution in both dark-field and simultaneous bright-field imaging, along with the high resolution in Z (depth sectioning) provided by the large probe incidence semiangle in the aberration-corrected instrument, to characterize the evolution of microstructure in a commercial Au/Fe2O3 water-gas shift catalyst during elevated temperature treatment. The phenomenon of Au diffusion to the surface of hematite support particles to form discrete crystalline Au nanoparticles in the 1–2 nm size range, after a prior leaching treatment to remove surface Au species has been characterized.

Copyright
Corresponding author
Corresponding author. E-mail: allardLFjr@ornl.gov
References
Hide All
Allard, L.F., Bigelow, W.C., Jose-Yacaman, M., Nackashi, D.P., Damiano, J. & Mick, S.E. (2009a). A new MEMS-based system for ultra-high-resolution imaging at elevated temperatures. Microsc Res Technique 72(3), 208215.
Allard, L.F., Bigelow, W.C., Nackashi, D., Damiano, J. & Mick, S.E. (2008). A new paradigm for ultra-high-resolution imaging at elevated temperatures. Microsc Microanal 14(S2), 792793.
Allard, L.F., Borisevich, A., Deng, W., Si, R., Flytzani-Stephanopoulos, M. & Overbury, S.H. (2009b). Evolution of gold structure during thermal treatment of Au/FeOx catalysts revealed by aberration-corrected electron microscopy. J Electron Microsc (Tokyo) 58(3), 199212.
Blake, R.L., Hessevick, R.E., Zoltai, T. & Finger, L.W. (1966). Refinement of the hematite structure. Amer Mineral 51, 123129.
Blom, D.A., Allard, L.F., Mishina, S. & O'Keefe, M.A. (2006). Early results from an aberration-corrected JEOL 2200FS STEM/TEM at Oak Ridge National Laboratory. Microsc Microanal 12, 483491.
Borisevich, A.Y., Lupini, A.R., Koschan, A.F., Mercimek, M., Abidi, M.A. & Pennycook, S.J. (2008). 3D Scanning transmission electron microscopy for catalysts: Imaging and data analysis. Microsc Microanal 14(S2), 168169.
Borisevich, A.Y., Lupini, A.R. & Pennycook, S.J. (2006a). Depth sectioning with the aberration-corrected scanning transmission electron microscope. Proceeding of the National Academy of Sciences 103(9), 30443048.
Borisevich, A.Y., Lupini, A.R., Travaglini, S. & Pennycook, S.J. (2006b). Depth sectioning of aligned crystals with the aberration-corrected scanning transmission electron microscope. J Electron Microsc (Tokyo) 55(1), 712.
Buffat, P. & Borel, J.-P. (1976). Size effect on the melting temperature of gold particles. Phys Rev A 13(6), 22872298.
De Jonge, N., Sougrat, R., Northan, B.M. & Pennycook, S.J. (2010). Three-dimensional scanning transmission electron microscopy of biological specimens. Microsc Microanal 16, 5362.
Deng, W., Carpenter, C., Yi, N. & Flytzani-Stephanopoulos, M. (2007). Comparison of the activity of Au/CeO2 and Au/Fe2O3 catalysts for the CO oxidation and the water-gas shift reactions. Topics in Catalysis 44(1–2), 199208.
Howe, J.Y., Allard, L.F., Bigelow, W.C. & Overbury, S.H. (2010). Synergy of combined (S)TEM imaging techniques for the characterization of catalyst behavior during in-situ heating. Microsc Microanal 16(S2), 312313.
Pennycook, S.J., Chisholm, M.F., Lupini, A.R., Varela, M., van Benthem, K., Borisevich, A.Y., Oxley, M.P., Luo, W. & Pantelides, S.T. (2008). Materials applications of aberration-corrected STEM. In Advances in Imaging and Electron Physics, Hawkes, P.W. (Ed.), 153, pp. 339340. San Diego, CA: Elsevier Inc.
Rashkeev, S.N., Lupini, A.R., Overbury, S.H., Pennycook, S.J. & Pantelides, S.T. (2007). Role of the nanoscale in catalytic CO oxidation by supported Au and Pt nanostructures. Phys Rev B 76, 035438035443.
Sun, J. (2002). A model for shrinkage of a spherical void in the center of a grain: Influence of lattice diffusion. J Mater Eng Perf 11(3), 322330.
Takahashi, Y., Ueno, F. & Nishiguchi, K. (1988). A numerical analysis of the void-shrinkage process controlled by surface diffusion. Acta Metall 36(11), 30073018.
van Benthem, K., Lupini, A.R., Kim, M., Baik, H.S., Doh, S.J., Lee, J.H., Oxley, M.P., Findlay, S.D., Allen, L.J. & Pennycook, S.J. (2005). Three-dimensional imaging of individual hafnium atoms inside a semiconductor device. Appl Phys Lett 87, 034104-1034104-3.
Wang, H. & Li, Z. (2004). The three-dimensional analysis for diffusive shrinkage of a grain-boundary void in stressed solid. J Mater Sci 39, 34253432.
Xin, X., Intaraprasonk, V. & Muller, D.A. (2008). Depth sectioning of individual dopant atoms with aberration-corrected scanning transmission electron microscopy. Appl Phys Lett 92(1), 013125.
Xin, X.L. & Muller, D.A. (2009). Aberration-corrected ADF-STEM depth sectioning and prospects for reliable 3D imaging in S/TEM. J Elect Microsc (Tokyo) 58(3), 157165.
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Microscopy and Microanalysis
  • ISSN: 1431-9276
  • EISSN: 1435-8115
  • URL: /core/journals/microscopy-and-microanalysis
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed