Tutorial Review: X-ray Mapping in Electron-Beam Instruments

  • John J. Friel (a1) and Charles E. Lyman (a2)
Abstract

This review traces the development of X-ray mapping from its beginning 50 years ago through current analysis procedures that can reveal otherwise obscure elemental distributions and associations. X-ray mapping or compositional imaging of elemental distributions is one of the major capabilities of electron beam microanalysis because it frees the operator from the necessity of making decisions about which image features contain elements of interest. Elements in unexpected locations, or in unexpected association with other elements, may be found easily without operator bias as to where to locate the electron probe for data collection. X-ray mapping in the SEM or EPMA may be applied to bulk specimens at a spatial resolution of about 1 μm. X-ray mapping of thin specimens in the TEM or STEM may be accomplished at a spatial resolution ranging from 2 to 100 nm, depending on specimen thickness and the microscope. Although mapping has traditionally been considered a qualitative technique, recent developments demonstrate the quantitative capabilities of X-ray mapping techniques. Moreover, the long-desired ability to collect and store an entire spectrum at every pixel is now a reality, and methods for mining these data are rapidly being developed.

Copyright
Corresponding author
Corresponding author. E-mail: charles.lyman@lehigh.edu
References
Hide All

REFERENCES

Allard, L.F. & Blake, D.F. (1982). The practice of modifying an analytical electron microscope to produce clean X-ray spectra. In Microbeam Analysis—1982, Heinrich, K.F.J. (Ed.), pp. 820. San Francisco, CA: San Francisco Press.
Anderhalt, R.W. & Sandborg, A.O. (1989). Quantitative compositional mapping in a scanning electron microscope with an energy-dispersive spectrometer. In Microbeam Analysis—1989, pp. 249253. San Francisco, CA: San Francisco Press.
Anderson, C.A. & Hasler, M.F. (1966). Extension of electron microprobe techniques to biochemistry by the use of long wavelength X-rays. In Proceedings of the Fourth International Conference on X-ray Optics and Microanalysis, Castaing, R., Deschamps, P. & Philibert, J. (Eds.), pp. 310327. Paris: Hermann.
Anderson, I.M. (1998). Statistical analysis of low-voltage EDS spectrum images. In Electron Microscopy 1998, Proceedings of the 14th International Congress on Electron Microscopy, Benavides, H.A. & Yacaman, M.J. (Eds.), pp. 357358. Philadelphia: Institute of Physics.
Anderson, I.M. (2000a). Spectrum imaging: Microanalysis for a new millennium. Microsc Microanal 6 (Suppl. 2), 10481049.
Anderson, I.M. (2000b). Spectrum imaging: The future of quantitative X-ray mapping? In Microbeam Analysis 2000, pp. 437438. Philadelphia: Institute of Physics.
Armstrong, J.T. (1988). Quantitative analysis of silicate and oxide materials: Comparison of Monte Carlo, ZAF, and phi-rho-z procedures. In Microbeam Analysis—1988, pp. 239245. San Francisco, CA: San Francisco Press.
Bennett, J.C. & Egerton, R.F. (1995). NiO test specimens for analytical electron microscopy: Round-robin results. Microsc Microanal 1, 143150.
Berger, M.J. (1963). Monte Carlo calculation of the penetration and diffusion of fast charged particles. In Methods in Computational Physics, Adler, B., Fernback, S. & Rotenberg, M. (Eds.), pp. 135215. New York: Academic Press.
Bonnet, N. (1998). Multivariate statistical methods for the analysis of microscope image series: Applications in materials science. J Microsc 190, 218.
Bonnet, N., Simova, E., Lebonvallet, S., & Kaplan, H. (1992). New applications of multivariate statistical analysis in spectroscopy and microscopy. Ultramicroscopy 40, 111.
Boyes, E.D. (2000). On low voltage scanning electron microscopy and chemical analysis. Microsc Microanal 6, 307316.
Boyes, E.D. (2001). Analytical potential of EDS at low voltages. Microchem Acta 138, 225234.
Bremier, S., Mostert, M., & Walker, C.T. (2000). Quantitative X-ray mapping in wavelength dispersive electron probe microanalysis. In Microbeam Analysis 2000, pp. 443444. Philadelphia: Institute of Physics.
Bright, D.S. (1995). Measurement of chemical components using scatter diagrams with principal component analysis. In Microbeam Analysis 1995, Etz, E. (Ed.), pp. 403404. Breckenridge, CO: VCH Publishers.
Bright, D.S. & Marinenko, R.B. (1992). Concentration histogram imaging. MSA Bull 22, 2128.
Bright, D.S. & Newbury, D.E. (1991). Concentration histogram imaging: A scatter diagram technique for viewing two or three related images. Anal Chem 63, 243A250A.
Bright, D.S. & Newbury, D.E. (2004). Maximum pixel spectrum: A new tool for detecting an drecovering rare, unanticipated features from spectrum image data cubes. J Microsc 216, 186193.
Brundle, D., Uritsky, Y., & Chernoff, D. (1996). Real-time simulation for X-ray microanalysis. Solid State Technol 39, 105194.
Buskes, H.A. & Baughman, G.D. (1988). Quantitative large-area mapping with an analytical scanning electron microscope: A study of low-level elemental segregation in continuous cast steel. In Microbeam Analysis—1988, pp. 4446. San Francisco, CA: San Francisco Press.
Cantrill, R.K., Guiver, T.A., & Moore, L.G. (1990). Large area X-ray mapping in continuously cast steel sections using the CAMECA SX-50 electron probe microanalyzer. Trans Roy Microsc Soc 1, 1922.
Castaing, R. (1951). Application of electron probes to local chemical and crystallographic analysis. Ph.D. dissertation, University of Paris.
Cazaux, J. (1996). Electron probe microanalysis of insulating materials: Quantitation problems and some possible solutions. X-ray Spectrom 25, 265280.
Chambers, W.F. (1981). Digitally controlled X-ray mapping. In Microbeam Analysis—1981, Geiss, R.H. (Ed.), pp. 4344. San Francisco, CA: San Francisco Press.
Cliff, G. & Kenway, P.B. (1982). The effects of spherical aberration in probe-forming lenses on probe size, image resolution, and X-ray spatial resolution in scanning transmission electron microscopy. In Microbeam Analysis—1982, Heinrich, K.F.J. (Ed.), pp. 107110. San Francisco, CA: San Francisco Press.
Cliff, G. & Lorimer, G.W. (1975). The quantitative analysis of thin specimens. J Microsc 103, 203207.
Colliex, C. & Mory, C. (1983). Quantitative aspects of scanning transmission electron microscopy. In Quantitative Electron Microscopy, Scottish Universities Summer School in Physics, Chapman, J.N. & Craven, A.J. (Eds.), pp. 149155. Glasgow, Scotland: Institute of Physics.
Cosslett, V.E. & Duncumb, P. (1956). Microanalysis by a flying-spot X-ray method. Nature 177, 11721173.
Duncumb, P. & Cosslett, V.E. (1957). A scanning microscope for X-ray emission pictures. In X-ray Microscopy and Microradiography, Cosslett, V.E., Engstrom, A. & Pattee, H.H. (Eds.), pp. 374380. New York: Academic Press.
Egerton, R.F. (1996). Electron Energy-Loss Spectroscopy in the Electron Microscope. New York: Plenum Press.
Egerton, R.F. & Cheng, S.C. (1994). Characterization of an analytical electron microscope with a NiO test specimen. Ultramicroscopy 55, 4354.
Ekelund, S. & Werlefors, T. (1976). A system for quantitative characterization of microstructures by combined image analysis and X-ray discrimination in the scanning electron microscope. In Scanning Electron Microscopy/1976, Johari, O. (Ed.), vol. 1, pp. 417424. Chicago, IL: IIT Research Institute.
Fiori, C. (1986a). Computer-aided imaging and interpretation. In Advanced Scanning Electron Microscopy and X-ray Microanalysis, Newbury, D.E., Joy, D.C., Echlin, P., Fiori, C. & Goldstein, J.I. (Eds.), pp. 181241. New York: Plenum.
Fiori, C.E. (1986b). Quantitative compositional analysis of biological cryosections. In Microbeam Analysis—1986, pp. 183186. San Francisco, CA: San Francisco Press.
Fiori, C.E., Leapman, R.D., Swyt, C.R., & Andrews, S.B. (1988). Quantitative X-ray mapping of biological cryosections. Ultramicroscopy 24, 237249.
Fiori, C.E., Swyt, C.R., & Gorlen, K.E. (1984). Continuum correction of X-ray images in scanning electron column instruments. In Microbeam Analysis—1984, Romig, A.D. & Goldstein, J.I. (Eds.), pp. 179185. San Francisco, CA: San Francisco Press.
Fitzgerald, R., Keil, K., & Heinrich, K.F.J. (1968). Solid-state energy dispersion spectrometer for electron-microprobe X-ray analysis. Science 159, 528530.
Friel, J.J. (1987). Computer-aided imaging of basaltic glass. In Microbeam Analysis—1987, pp. 325326. San Francisco, CA: San Francisco Press.
Friel, J.J. & Batcheler, R. (2002). Automatic phase segmentation of spectrum images. Microsc Microanal 8 (Suppl. 2), 350351.
Friel, J.J. & Greenhut, V. (1997). Novel technology for X-ray mapping of ceramic microstructures. J Am Ceram Soc 80, 32053208.
Friel, J.J. & Prestridge, E.B. (2002). Combined LM, SEM, and X-ray microanalysis of tint-etched cast iron. Microsc Anal 57, 57.
Fritz, G.S., McCarthy, J.J., & Lee, R.J. (1981). Interactive software for automated particulate analysis. Microbeam Analysis—1981, pp. 5760. San Francisco, CA: San Francisco Press.
Gao, N., Ponomarev, I.Y., Xiao, Q.F., Gibson, W.M., & Carpenter, D.A. (1996). Monolithic polycapillary focusing optics and their applications in microbeam X-ray fluorescence. Appl Phys Lett 69, 15291531.
Garratt-Reed, A.J. (1990). Applications of high-resolution X-ray mapping. In Microbeam Analysis—1990, Michael, J.R. & Ingram, P. (Eds.), pp. 272274. San Francisco, CA: San Francisco Press.
Goldstein, J.I., Costley, J.L., Lorimer, G.W., & Reed, S.J.B. (1977). Quantitative X-ray analysis in the electron microscope. In Scanning Electron Microscopy/1977. Johari, O. (Ed.), vol. 1, pp. 315324. Chicago, IL: IIT Research Institute.
Goldstein, J.I., Lyman, C.E., & Zhang, J. (1990). In Microbeam Analysis—1990, Michael, J.R. & Ingram, P. (Eds.), pp. 265271. San Francisco, CA: San Francisco Press.
Goldstein, J.I., Newbury, D.E., Echlin, P., Joy, D.C., Fiori, C., & Lifshin, E. (1981). Scanning Electron Microscopy and X-ray Microanalysis. New York: Plenum Press.
Goldstein, J.I., Newbury, D.E., Echlin, P., Joy, D.C., Lyman, C.E., Romig, A.D., Fiori, C.E., & Lifshin, E. (1992). Scanning Electron Microscopy and X-ray Microanalysis. New York: Plenum.
Goldstein, J.I., Newbury, D.E., Joy, D.C., Lyman, C.E., Echlin, P., Lifshin, E., Sawyer, L., & Michael, J.R. (2003). Scanning Electron Microscopy and X-ray Microanalysis. New York: Kluwer Academic/Plenum Publishers.
Goldstein, J.I., Williams, D.B., & Cliff, G. (1986). Quantitative X-ray analysis. In Principles of Analytical Electron Microscopy, Joy, D.C., Romig, A.D. & Goldstein, J.I. (Eds.), pp. 155217. New York: Plenum Press.
Green, M. (1963). A Monte Carlo calculation of the spatial distribution of characteristic X-ray production in a solid target. Proc Phys Soc 82, 204215.
Hall, T.A. (1979). Problems of the continuum-normalization method for the quantitative analysis of sections of soft tissue. In Microbeam Analysis in Biology, Lechene, C. & Warner, R.R. (Eds.), pp. 185208. New York: Academic Press.
Hall, T.A. & Gupta, B.L. (1982). Quantitation for the X-ray microanalysis of cryosections. J Microsc 126, 333345.
Harman, H.H. (1967). Modern Factor Analysis. Chicago: University of Chicago Press.
Heinrich, K.F.J. (1962a). Concentration mapping device for the scanning electron probe microanalyzer. Rev Sci Instrum 33, 884.
Heinrich, K.F.J. (1962b). Oscilloscope readout of electron microprobe data. Adv X-ray Anal 6, 291300.
Heinrich, K.F.J., Newbury, D.E., & Yakowitz, H. (1976). Use of Monte Carlo Calculations in Electron Probe Microanalysis and Scanning Electron Microscopy. Washington, DC: National Institute of Science and Technology.
Hoover, M.R., White, E.W., Lebiedzik, J., & Johnson, G.G. (1975). Automated characterization of particulates and inclusions by computer-controlled SEM/probe. In Proceedings of the 10th Conference of the Microbeam Analysis Society, pp. 54A54B. Bethlehem, PA: Microbeam Analysis Society.
Hovington, P., Drouin, D., & Gauvin, R. (1997). Casino: A new Monte Carlo code for electron beam interaction, part I: Description of the program. Scanning 19, 114.
Hunneyball, P.D., Jacobs, M.H., & Law, T.J. (1981). Digital X-ray mapping from thin foils. In Quantitative Microanalysis with High Spatial Resolution, Lorimer, M.J.G.W. & Doig, P. (Eds.), pp. 195201. London: The Metals Society.
Hunt, J.A. & Williams, D.B. (1991). Electron energy-loss spectrum-imaging. Ultramicroscopy 38, 4773.
Ingram, P., LeFurgey, A., Davilla, S.D., Sommer, S.R., Mandel, L.J., Lieberman, M., & Herlong, J.R. (1988). Quantitative elemental X-ray imaging of biological cryosections. In Microbeam Analysis—1988, Newbury, D.E. (Ed.), pp. 433439. San Francisco, CA: San Francisco Press.
Jbara, O., Cazaux, J., & Trebbia, P. (1995). Sodium diffusion in glasses during electron irradiation. J Appl Phys 78, 868875.
Jeanguillaume, C. & Colliex, C. (1989). Spectrum-image: The next step in EELS digital acquisition and processing. Ultramicroscopy 28, 252257.
Joy, D.C. (1995). Monte Carlo Modeling for Electron Microscopy and Microanalysis. New York: Oxford University Press.
Kawasaki, M., Oikawa, T., Ibe, K., Park, K.-H., & Shiojiri, M. (1998). EDS elemental mapping of a DRAM with an FE-TEM. J Elec Microsc 47, 335343.
Keast, V.J. & Williams, D.B. (1999). Quantitative compositional mapping of Bi segregation to grain boundaries in Cu. Acta Mater 47, 39994008.
Kelly, J.F., Lee, R.J., & Lentz, S. (1980). Automatic characterization of fine particles. In Scanning Electron Microscopy/1980, Johari, O. (Ed.), vol. 1, pp. 311322. AMF O'Hare, IL: SEM Inc.
Kotula, P.G., Keenan, M.R., Grant, R.P., & Hlava, P.F. (2004a). Multivariate statistical analysis of wavelength and energy-dispersive X-ray spectral images. Microsc Microanal 10 (Suppl. 2), 118119.
Kotula, P.G., Keenan, M.R., & Michael, J.R. (2003a). Automated analysis of SEM X-ray spectral images: A powerful new microanalysis tool. Microsc Microanal 9, 117.
Kotula, P.G., Keenan, M.R., & Michael, J.R. (2003b). Tomographic spectral imaging: Comprehensive 3D X-ray microanalysis. Microsc Microanal 9 (Suppl. 2), 10041005.
Kotula, P.G., Keenan, M.R., & Michael, J.R. (2004b). Tomographic spectral imaging with a dual-beam FIB/SEM: 3D microanalysis. Microsc Microanal 10 (Suppl. 2), 11321133.
Kotula, P.G., Keenan, M.R., & Michael, J.R. (2006). Tomographic spectral imaging with multivariate statistical analysis: Comprehensive 3D microanalysis. Microsc Microanal 12, 3648 (this issue).
Kuypers, S. (2001). Soft X-rays and low voltage SEM in practice. Microchem Acta 138, 235247.
Lamvik, M.K., Ingram, P., Menon, R.G., Beese, L.S., Davilla, S.D., & LeFurgey, A. (1989). Correction for specimen movement after acquisition of element-specific electron microprobe images. J Microsc 156, 183190.
Lee, R.J., Huggins, F.E., & Huffman, G.P. (1978). Correlated Mossbauer-SEM studies of coal mineralogy. In Scanning Electron Microscopy/1978, Johari, O. (Ed.), vol. 1, pp. 561568. AMF O'Hare, IL: SEM Inc.
LeFurgey, A., Davilla, S.D., Kopf, D.A., Sommer, J.R., & Ingram, P. (1992). Real-time quantitative elemental analysis and mapping microchemical imaging in cell physiology. J Microsc 165, 191223.
Legge, G.J.F. & Hammond, I. (1979). Total quantitative recording of elemental maps and spectra with a scanning microprobe. J Microsc 117, 201210.
Long, N.J. (1990). Digital X-ray mapping on an HB501 STEM: A new approach for the analysis of interfaces. Ultramicroscopy 34, 8183.
Lyman, C.E. (1986). Digital X-ray imaging of small particles. Ultramicroscopy 20, 119124.
Lyman, C.E. (1992). Compositional imaging in the electron microscope: An overview. EMSA Bull 22, 19.
Lyman, C.E., Goldstein, J.I., Williams, D.B., Ackland, D.W., von Harrach, S., Nicholls, A.W., & Statham, P.J. (1994). High-performance X-ray detection in a new analytical electron microscope. J Microsc 176, 8598.
Lyman, C.E., Stenger, H.G., & Michael, J.R. (1987). Analytical electron microscopy of a sulfur-poisoned palladium catalyst with a dedicated STEM. Ultramicroscopy 22, 129133.
Malis, T., Cheng, S.C., & Egerton, R.F. (1988). EELS log-ratio technique for specimen-thickness measurement in the TEM. J Electron Microsc Tech 8, 193200.
Marinenko, R.B., Myklebust, R.L., Bright, D.B., & Newbury, D.E. (1987). Digital compositional mapping with standard map corrections for wavelength-dispersive spectrometry defocusing. J Microsc 145, 207223.
McCamy, C.S. (1998). On the number of discernible colors: Comment. Color Res Appl 23, 337.
McCarthy, J.J. (1979). A new technique for beam current normalization in energy dispersive analysis. In Microbeam Analysis—1979, pp. 305306. San Francisco, CA: San Francisco Press.
McCarthy, J.J. (1998). Thirty years of energy-dispersive spectrometry in microanalysis: Introduction. Microsc Microanal 4, 551.
McCarthy, J.J., Fritz, G.S., & Lee, R.J. (1981). Acquisition, storage, and display of video and X-ray images. In Microbeam Analysis—1981, pp. 3034. San Francisco, CA: San Francisco Press.
Meeker, G.P. (1995). Constraints on formation processes of two coarse-grained calcium-aluminum-rich inclusions: A study of mantles, islands, and cores. Meteoritics 30, 7184.
Melford, D.A. & Duncumb, P. (1958). The metallurgical application of X-ray scanning microanalysis. Metallurgia 57, 159161.
Michael, J.R. & Taylor, K.A. (1988). High-resolution X-ray imaging of small copper-rich precipitates in steels. In 46th Annual Meeting of the Electron Microscopy Society of America, Bailey, G.W. (Ed.), pp. 528529. San Francisco, CA: San Francisco Press.
Miller, P.R., Reid, A.F., & Zuiderwyk, M.A. (1982). QEM*SEM image analysis in the determination of modal assays, mineral associations, and mineral liberation. In Proceedings—XIV International Mineral Processing Congress, Toronto, Canada & Maltby, P.D.R. (Ed.), vol. 8, p. 3. Amsterdam: Elsevier.
Mosteller, F. & Tukey, J.W. (1977). Data Analysis and Regression. Reading, MA: Addison-Wesley.
Mott, R.B. & Friel, J.J. (1999). Saving the photons: Mapping X-rays by position-tagged spectrometry. J Microsc 193, 214.
Mott, R.B., Waldman, C.G., Batcheler, R., & Friel, J.J. (1995). Position-tagged spectrometry: A new approach for EDS spectrum imaging. In Proceedings Microscopy and Microanalysis 1995, Bailey, G.W., Ellisman, M.H., Hennigar, R.A. & Zaluzec, N.J. (Eds.), pp. 592593. New York: Jones and Begell.
Myklebust, R.L., Newbury, D.E., & Marinenko, R.B. (1989). Strategies for background subtraction in electron probe microanalysis/X-ray compositional mapping. Analyt Chem 61, 16121618.
Newbury, D.E. (1992). Compositional imaging by electron probe microanalysis: Capabilities, limitations, opportunities. MSA Bull 22, 1120.
Newbury, D.E. (2006). The new X-ray mapping: X-ray spectrum imaging above 100 kHz output count rate with the silicon drift detector. Microsc Microanal 12, 2635 (this issue).
Newbury, D.E. & Bright, D.S. (1999). Logarithmic 3-band color encoding: Robust method for display and comparison of compositional maps in electron probe X-ray microanalysis. Microsc Microanal 5, 333343.
Newbury, D.E. & Bright, D.S. (2005). “Derived spectra” software tools for detecting spatial and spectral features in spectrum images. Scanning 27, 1522.
Newbury, D.E., Fiori, C.E., Marinenko, R.B., Myklebust, R.L., Swyt, C.R., & Bright, D.S. (1990a). Compositional mapping with the electron probe microanalyzer, part 1. Anal Chem 62, 1159A1166A.
Newbury, D.E., Fiori, C.E., Marinenko, R.B., Myklebust, R.L., Swyt, C.R., & Bright, D.S. (1990b). Compositional mapping with the electron probe microanalyzer, part 2. Anal Chem 62, 1245A1254A.
Newbury, D.E. & Joy, D.C. (1986). Modeling electron beam-specimen interactions. In Advanced Scanning Electron Microscopy and Microanalysis, Newbury, D.E., Joy, D.C., Echlin, P., Fiorim, C.E. & Goldstein, J.I. (Eds.), pp. 343. New York: Plenum Press.
Newbury, D.E., Marinenko, R.B., Myklebust, R.L., & Bright, D.S. (1991). Quantitative compositional mapping with the electron probe microanalyzer. In Electron Probe Quantitation, Heinrich, K.F.J. & Newbury, D.E. (Eds.), pp. 335369. New York: Plenum Press.
Nickerson, D. & Newhall, S.M. (1943). A psychological color solid. J Opt Soc Am 33, 419422.
Ono, Y., Nielsen, C.H., Tagata, S., & Seo, Y. (1985). High-speed wide-area analysis by electron probe. In Microbeam Analysis—1985, pp. 145147. San Francisco, CA: San Francisco Press.
Papworth, A.J. & Williams, D.B. (2000). Information obtained by X-ray mapping large sample areas in a FEGSTEM. In Microbeam Analysis 2000, Kona, H.I., Williams, D.B. & Shimizu, R. (Eds.), pp. 143144. Philadelphia: Institute of Physics.
Pointer, M.R. & Attridge, G.G. (1998). The number of discernible colours. Color Res Appl 23, 5254.
Reed, S.J.B. (1982). The single-scattering model and spatial resolution in X-ray analysis of thin foils. Ultramicroscopy 7, 405409.
Reuter, K.B. & Lyman, C.E. (1991). Improved stability of alkali metals on catalysts during analytical electron microscopy. In Proceedings of the 49th Annual Meeting of the Electron Microscopy Society of America, Bailey, G.W. & Hall, E.L. (Eds.), pp. 10161017. San Jose, CA: San Francisco Press.
Robinson, B.W., Ware, N.G., & Smith, D.G.W. (1998). Modern electron-microprobe trace-element analysis in mineralogy. In Modern Approaches to Ore and Environmental Mineralogy, Cabri, L.J. & Vaughan, D.J. (Eds.), Short Course Series vol. 27, pp. 153180. Ottawa: Mineralogical Association of Canada.
Russ, J.C. (1990). Computer-Assisted Microscopy. New York: Plenum Press.
Russ, J.C. (1999). The Image Processing Handbook. Boca Raton, FL: CRC Press.
Schultz, M., Rudolf, F., & Gallitelli, M.-F. (1999). Improvement in quantitative X-ray microanalysis of biological cryosections. Microsc Microanal 5, 187196.
Somlyo, A.P. (1984). Compositional mapping in biology: X-rays and electrons. J Ultrastruct Res 88, 135142.
Statham, P.J. (1988). Pitfalls and advances in quantitative elemental mapping. Scanning 10, 245252.
Statham, P.J. (1995). Quantifying benefits of resolution and count rate in EDX microanalysis. In X-ray Spectrometry in Electron Beam Instruments, Williams, D.B., Goldstein, J.I. & Newbury, D.E. (Eds.), pp. 101126. New York: Plenum.
Strüder, L., Meidinger, N., Stotter, D., Kemmer, J., Lechner, P., Leutenegger, P., Soltau, H., Eggert, F., Rohde, M., & Schülein, T. (1999). High-resolution X-ray spectroscopy close to room temperature. Microsc Microanal 4, 622631.
Sutfin, L.V. & Ogilvie, R.E. (1971). Role of the gas flow proportional counter in energy dispersion analysis. In Energy Dispersion X-ray Analysis: X-ray and Electron Probe Analysis, Russ, J.C. (Ed.), pp. 197216. Philadelphia, PA: ASTM.
Takahashi, H. & Okumura, T. (1998). Wide area mapping of uneven specimens in an electron probe X-ray microanalyzer with wavelength dispersive spectrometers. J Electron Microsc 47, 3946.
Titchmarsh, J.M. & Dumbill, S. (1996). Multivariate statistical analysis of FEG-STEM EDX spectra. J Microsc 184, 195207.
Titchmarsh, J.M., Dumbill, S., & Vatter, I.A. (1995). Investigation of interfacial segregation in steels using multivariate analysis of EDX spectra. In Microbeam Analysis—1995, Etz, E.S. (Ed.), pp. 259260. New York: VCH Publishers.
Tomura, T., Okano, H., Hara, K., & Wantanabe, T. (1968). Multistep intensity indication in scanning microanalysis. Adv X-ray Anal 11, 316325.
Trebbia, P. & Bonnet, N. (1990). EELS elemental mapping with unconventional methods I. Theoretical basis: Image analysis with multivariate statistics and entropy concepts. Ultramicroscopy 34, 165178.
Trebbia, P., Wulveryck, J.M., & Bonnet, N. (1995). Progress in quantitative elemental mapping by X-ray imaging. Microbeam Anal 4, 85102.
Tsuneta, R., Koguchi, M., Nakamura, K., & Nishida, A. (2002). A specimen-drift-free EDX mapping system in a STEM for observing two-dimensional profiles of low dose elements in fine semiconductor devices. J Electron Microsc 51, 167171.
Vale, S.H. (1987). Drift corrected X-ray mapping in the analytical electron microscope. In EMAG-1987: Analytical Electron Microscopy, Lorimer, G.W. (Ed.), pp. 1518. London: Institute of Metals.
Wachtman, J.B. (1993). Characterization of Materials. Stoneham, MA: Butterworth-Heinemann.
Warley, A. (1997). X-ray Microanalysis for Biologists. London: Portland Press.
Watanabe, M., Carpenter, D.T., Barmak, K., & Williams, D.B. (1997). Quantitative X-ray mapping with high resolution. In Electron Microscopy and Analysis 1997, pp. 295298. Bristol: Institute of Physics.
Watanabe, M., Horita, Z., & Nemoto, M. (1996). Absorption correction and thickness determination using zeta factor in quantitative X-ray microanalysis. Ultramicroscopy 65, 187198.
Watanabe, M. & Williams, D.B. (1999). Atomic-level detection by X-ray microanalysis in the analytical electron microscope. Ultramicroscopy 78, 89101.
Watanabe, M., Williams, D.B., & Tomokiyo, Y. (2003). Comparison of detectability limits for elemental mapping by EF-TEM and STEM-XEDS. Micron 34, 173183.
Williams, D.B. & Carter, C.B. (1996). Transmission Electron Microscopy. New York: Plenum Press.
Williams, D.B. & Goldstein, J.I. (1981). Artifacts encountered in energy dispersive X-ray spectrometry in the analytical electron microscope. In Energy Dispersive X-ray Spectrometry, Heinrich, K.F.J., Newbury, D.E., Myklebust, R.L. & Fiori, C.E. (Eds.). NBS Special Publication 604, pp. 341349. Washington, DC: National Bureau of Standards.
Williams, D.B., Goldstein, J.I., & Newbury, D.E., Eds. (1995). X-ray Spectrometry in Electron Beam Instruments. New York: Plenum Press.
Williams, D.B., Papworth, A.J., & Watanabe, M. (2002). High resolution X-ray mapping in the STEM. J Electron Microsc 51(Suppl.), S113S126.
Wong, J.G., Wilkinson, L.E., Chen, S.W., Izutsu, K.T., Johnson, D.E., & Cantino, M.E. (1989). Quantitative elemental imaging in the analytical electron microscope with biological applications. Scanning 11, 1219.
Ziebold, T.O. (1967). Precision and sensitivity in electron microprobe analysis. Anal Chem 39, 858861.
Zierold, K., Tardent, P., & Burakov, S.V. (1991). Elemental mapping of cryosections from cnidarian nematocytes. Scan Microsc 5, 439444.
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Microscopy and Microanalysis
  • ISSN: 1431-9276
  • EISSN: 1435-8115
  • URL: /core/journals/microscopy-and-microanalysis
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords

Metrics

Altmetric attention score

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed