Skip to main content
×
×
Home

The Munich Compact Light Source: Biomedical Research At a Laboratory-Scale Inverse-Compton Synchrotron X-ray Source

  • Benedikt Günther (a1) (a2) (a3), Martin Dierolf (a1) (a2), Regine Gradl (a1) (a2) (a4), Elena Eggl (a1) (a2), Christoph Jud (a1) (a2), Lorenz Hehn (a1) (a5), Stephanie Kulpe (a1) (a2), Bernhard Gleich (a1) (a2), Madleen Busse (a1) (a2), Kaye S. Morgan (a1) (a2) (a4) (a6), Klaus Achterhold (a1) (a2) and Franz Pfeiffer (a1) (a2) (a5)...
    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      The Munich Compact Light Source: Biomedical Research At a Laboratory-Scale Inverse-Compton Synchrotron X-ray Source
      Available formats
      ×
      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      The Munich Compact Light Source: Biomedical Research At a Laboratory-Scale Inverse-Compton Synchrotron X-ray Source
      Available formats
      ×
      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      The Munich Compact Light Source: Biomedical Research At a Laboratory-Scale Inverse-Compton Synchrotron X-ray Source
      Available formats
      ×
Abstract
Copyright
References
Hide All
[1] Eggl, E, et al, Journal of Synchrotron Radiation 23 2016) p. 1137.
[2] Achterhold, K, et al, Scientific Reports 3 2013) p. 1313.
[3] Eggl, E, et al, PNAS 112(18 2015) p. 5567.
[4] Eggl, E, et al, Scientific Reports 7 2017) p. 42211.
[5] Jud, C, et al, Scientific Reports 7 2017) p. 14477.
[6] Gradl, R, et al, Scientific Reports 7 2017) p. 4908.
[7] The MuCLS was developed and constructed by Lyncean Technologies Inc. We acknowledge financial support through the Center of Advanced Laser Applications (CALA) and the Cluster of Excellence of the German Research Foundation (DFG) Munich-Centre for Advanced Photonics (MAP).
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Microscopy and Microanalysis
  • ISSN: 1431-9276
  • EISSN: 1435-8115
  • URL: /core/journals/microscopy-and-microanalysis
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed