Operation of TEAM I in a User Environment at NCEM

  • Peter Ercius (a1), Markus Boese (a1), Thomas Duden (a2) and Ulrich Dahmen (a1)
Abstract

TEAM I is the final product of the Transmission Electron Aberration-corrected Microscope (TEAM) Project, a collaborative project funded by the Department of Energy with the goal of designing and building a platform for a next generation aberration-corrected electron microscope capable of image resolution of up to 50 pm. The TEAM instrument incorporates a number of new technologies, including spherical- and chromatic-aberration correction, an all-piezo-electric sample stage and an active-pixel direct electron detector. This article describes the functionality of this advanced instrumentation, its response to changes in environment or operating conditions, and its stability during daily operation within the National Center for Electron Microscopy user facility.

Copyright
Corresponding author
Corresponding author. E-mail: percius@lbl.gov
References
Hide All
Battaglia, M., Contarato, D., Denes, P., Doering, D., Duden, T., Krieger, B., Giubilato, P., Gnani, D. & Radmilovic, V. (2010). Characterisation of a CMOS active pixel sensor for use in the team microscope. Nucl Instrum Meth A 622(3), 669677.
Battaglia, M., Contarato, D., Denes, P. & Giubilato, P. (2009). Cluster imaging with a direct detection CMOS pixel sensor in transmission electron microscopy. Nucl Instrum Meth A 608(2), 363365.
Dahmen, U., Erni, R., Radmilovic, V., Ksielowski, C., Rossell, M.-D. & Denes, P. (2009). Background, status and future of the transmission electron aberration-corrected microscope project. Philos T R Soc A 367(1903), 37953808.
Duden, T. (2009). Capacitance displacement and rotation sensor. US Patent 2011/0175629.
Duden, T., Gautam, A. & Dahmen, U. (2011). Kspacenavigator as a tool for computer-assisted sample tilting in high-resolution imaging, tomography and defect analysis. Ultramicroscopy 111(11), 15741580.
Gianuzzi, L.A. & Stevie, F.A. (2004). Introduction to Focused Ion Beams: Instrumentation, Theory, Techniques and Practice. New York: Springer.
Girit, C.O., Meyer, J.C., Erni, R., Rossell, M.D., Kisielowski, C., Yang, L., Park, C.-H., Crommie, M.F., Cohen, M.L., Louie, S.G. & Zettl, A. (2009). Graphene at the edge: Stability and dynamics. Science 323(5922), 17051708.
Haider, M., Hartel, P., Miller, H., Uhlemann, S. & Zach, J. (2010). Information transfer in a TEM corrected for spherical and chromatic aberration. Microsc Microanal 16, 393408.
Haider, M., Muller, H., Uhlemann, S., Zach, J., Loebau, U. & Hoeschen, R. (2008). Prerequisites for a Cc/Cs corrected ultrahigh-resolution TEM. Ultramicroscopy 108(3), 167178.
Haider, M., Uhlemann, S. & Zach, J. (2000). Upper limits for the residual aberrations of a high-resolution aberration-corrected stem. Ultramicroscopy 81(3-4), 163175.
Kaiser, U., Biskupek, J., Meyer, J., Leschner, J., Lechner, L., Rose, H., Stoger-Pollach, M., Khlobystov, A., Hartel, P., Muller, H., Haider, M., Eyhusen, S. & Benner, G. (2011). Transmission electron microscopy at 20kv for imaging and spectroscopy. Ultramicroscopy 111(8), 12391246.
Kisielowski, C., Freitag, B., Bischoff, M., van Lin, H., Lazar, S., Knippels, G., Tiemeijer, P., van der Stam, M., von Harrach, S., Stekelenburg, M., Haider, M., Uhlemann, S., Mller, H., Hartel, P., Kabius, B., Miller, D., Petrov, I., Olson, E., Donchev, T., Kenik, E., Lupini, A., Bentley, J., Pennycook, S., Anderson, I., Minor, A., Schmid, A., Duden, T., Radmilovic, V., Ramasse, Q., Watanabe, M., Erni, R., Stach, E., Denes, P. & Dahmen, U. (2008). Detection of single atoms and buried defects in three dimensions by aberration-corrected electron microscope with 0.5-information limit. Microsc Microanal 14(5), 469477.
Krivanek, O., Dellby, N. & Lupini, A. (1999). Towards sub-electron beams. Ultramicroscopy 78(1-4), 111.
Lee, Z., Jeon, K.-J., Dato, A., Erni, R., Richardson, T.J., Frenklach, M. & Radmilovic, V. (2009). Direct imaging of soft/hard interfaces enabled by graphene. Nano Lett 9(9), 33653369.
Lee, Z., Meyer, J., Rose, H. & Kaiser, U. (2012). Optimum HRTEM image contrast at 20 kV and 80 kV—Exemplified by graphene. Ultramicroscopy 112(1), 3946.
Schmid, A. & Andresen, N. (2011). Motorized manipulator for positioning a TEM specimen. US Patent 7,851,769.
van de Water, J., van den Oetelaar, J., Wagner, R., Slingerland, H., Bruggers, J., Ottevanger, A., Schmid, A., Olson, E., Petrov, I., Donchev, T. & Duden, T. (2011). Manipulator for rotating and translating a sample holder. US Patent 7,884,326.
Van den Broek, W., Van Aert, S. & Van Dyck, D. (2012). Fully automated measurement of the modulation transfer function of charge-coupled devices above the Nyquist frequency. Microsc Microanal 18(2), 336342.
Zemlin, F., Weiss, K., Schiske, P., Kunath, W. & Herrmann, K.-H. (1978). Coma-free alignment of high resolution electron microscopes with the aid of optical diffractograms. Ultramicroscopy 3, 4960.
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Microscopy and Microanalysis
  • ISSN: 1431-9276
  • EISSN: 1435-8115
  • URL: /core/journals/microscopy-and-microanalysis
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords:

Metrics

Full text views

Total number of HTML views: 12
Total number of PDF views: 55 *
Loading metrics...

Abstract views

Total abstract views: 295 *
Loading metrics...

* Views captured on Cambridge Core between September 2016 - 13th June 2018. This data will be updated every 24 hours.