Optimized Deconvolution for Maximum Axial Resolution in Three-Dimensional Aberration-Corrected Scanning Transmission Electron Microscopy

  • Ranjan Ramachandra (a1) and Niels de Jonge (a1)
Abstract
Abstract

Three-dimensional (3D) datasets were recorded of gold nanoparticles placed on both sides of silicon nitride membranes using focal series aberration-corrected scanning transmission electron microscopy (STEM). Deconvolution of the 3D datasets was applied to obtain the highest possible axial resolution. The deconvolution involved two different point spread functions, each calculated iteratively via blind deconvolution. Supporting membranes of different thicknesses were tested to study the effect of beam broadening on the deconvolution. It was found that several iterations of deconvolution was efficient in reducing the imaging noise. With an increasing number of iterations, the axial resolution was increased, and most of the structural information was preserved. Additional iterations improved the axial resolution by maximal a factor of 4 to 6, depending on the particular dataset, and up to 8 nm maximal, but also led to a reduction of the lateral size of the nanoparticles in the image. Thus, the deconvolution procedure optimized for the highest axial resolution is best suited for applications where one is interested in the 3D locations of nanoparticles only.

Copyright
Corresponding author
Corresponding author. E-mail: niels.de.jonge@vanderbilt.edu
References
Hide All
G. Behan , E.C. Cosgriff , A.I. Kirkland & P.D. Nellist (2009). Three-dimensional imaging by optical sectioning in the aberration-corrected scanning transmission electron microscope. Philos T A Math Phys Eng Sci 367, 38253844.

A.Y. Borisevich , A.R. Lupini & S.J. Pennycook (2006). Depth sectioning with the aberration-corrected scanning transmission electron microscope. Proc Natl Acad Sci 103, 30443048.

A.V. Crewe & J. Wall (1970). A scanning microscope with 5 Å resolution. J Mol Biol 48, 375393.

N. de Jonge , W.C. Bigelow & G.M. Veith (2010a). Atmospheric pressure scanning transmission electron microscopy. Nano Lett 10, 10281031.

N. de Jonge , R. Sougrat , B.M. Northan & S.J. Pennycook (2010b). Three-dimensional scanning transmission electron microscopy of biological specimens. Microsc Microanal 16, 5463.

M.J. Dukes , R. Ramachandra , B. Jean-Pierre , G.M. Jerome & N. de Jonge (2011). Three-dimensional locations of gold-labeled proteins in a whole mount eukaryotic cell obtained with 3 nm precision using aberration-corrected scanning transmission electron microscopy. J Struct Biol 174, 552562.

R.F. Egerton , P. Li & M. Malac (2004). Radiation damage in the TEM and SEM. Micron 35, 399409.

S.P. Frigo , Z.H. Levine & N.J. Zaluzec (2002). Submicron imaging of buried integrated circuit structures using scanning confocal electron microscopy. Appl Phys Lett 81, 21122114.

M. Haider , S. Uhlemann & J. Zach (2000). Upper limits for the residual aberrations of a high-resolution aberration-corrected STEM. Ultramicroscopy 81, 163175.

A. Hashimoto , M. Shimojo , K. Mitsuishi & M. Takeguchi (2010). Three-dimensional optical sectioning by scanning confocal electron microscopy with a stage-scanning system. Microsc Microanal 16, 233238.

T. Holmes & N. O'Connor (2000). Blind deconvolution of 3D transmitted light brightfield micrographs. J Microsc 200, 114127.

T.J. Holmes (1992). Blind deconvolution of quantum-limited incoherent images: Maximum likelihood approach. J Opt Soc Am 9, 10521061.

R. Hovden , H.L. Xin & D.A. Muller (2011). Extended depth of field for high-resolution scanning transmission electron microscopy. Microsc Microanal 17, 7580.

O.L. Krivanek , N. Dellby & A.R. Lupini (1999). Towards sub-angstrom electron beams. Ultramicroscopy 78, 111.

A.R. Lupini & N. de Jonge (2011). The three-dimensional point spread function of aberration-corrected scanning transmission electron microscopy. Microsc Microanal 17(5), 817826.

P.D. Nellist , G. Behan , A.I. Kirkland & C.J.D. Hetherington (2006). Confocal operation of a transmission electron microscope with two aberration correctors. Appl Phys Lett 89, 124105.

P.D. Nellist , M.F. Chisholm , N. Dellby , O.L. Krivanek , M.F. Murfitt , Z.S. Szilagyi , A.R. Lupini , A. Borisevich , W.H. Sides & S.J. Pennycook (2004). Direct sub-angstrom imaging of a crystal lattice. Science 305, 1741.

J.B. Pawley (1995). Handbook of Biological Confocal Microscopy. New York: Springer.

R.C. Puetter , T.R. Gosnell & A. Yahil (2005). Digital image reconstruction: Deblurring and denoising. Annu Rev Astron Astrophys 43, 139194.

R. Ramachandra , H. Demers & N. de Jonge (2011). Atomic-resolution scanning transmission electron microscopy through 50 nm-thick silicon nitride membranes. Appl Phys Lett 98, 93109.

H. Stahlberg & T. Walz (2008). Molecular electron microscopy: State of the art and current challenges. ACS Chem Biol 3, 268281.

S. Uhlemann & M. Haider (1998). Residual wave aberrations in the first spherical aberration corrected transmission electron microscope. Ultramicroscopy 72, 109119.

K. van Benthem , A.R. Lupini , M. Kim , H.S. Baik , S.J. Doh , J.H. Lee , M.P. Oxley , S.D. Findlay , L.J. Allen & S.J. Pennycook (2005). Three-dimensional imaging of individual hafnium atoms inside a semiconductor device. Appl Phys Lett 87, 034104.

H.L. Xin & D.A. Muller (2009). Aberration-corrected ADF-STEM depth sectioning and prospects for reliable 3D imaging in S/TEM. J Electron Microsc (Tokyo) 58, 157165.

Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Microscopy and Microanalysis
  • ISSN: 1431-9276
  • EISSN: 1435-8115
  • URL: /core/journals/microscopy-and-microanalysis
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords:

Metrics

Full text views

Total number of HTML views: 1
Total number of PDF views: 10 *
Loading metrics...

Abstract views

Total abstract views: 156 *
Loading metrics...

* Views captured on Cambridge Core between September 2016 - 17th October 2017. This data will be updated every 24 hours.