Skip to main content
×
Home
    • Aa
    • Aa

In Vivo Biostability of CVD Silicon Oxide and Silicon Nitride Films

  • John M. Maloney (a1), Sara A. Lipka (a1) and Samuel P. Baldwin (a1)
Abstract
Abstract

Low pressure chemical vapor deposition (LPCVD) and plasma enhanced chemical vapor deposition (PECVD) silicon oxide and silicon nitride films were implanted subcutaneously in a rat model to study in vivo behavior of the films. Silicon chips coated with the films of interest were implanted for up to one year, and film thickness was evaluated by spectrophotometry and sectioning. Dissolution rates were estimated to be 0.33 nm/day for LPCVD silicon nitride, 2.0 nm/day for PECVD silicon nitride, and 3.5 nm/day for PECVD silicon oxide. A similar PECVD silicon oxide dissolution rate was observed on a silicon oxide / silicon nitride / silicon oxide stack that was sectioned by focused ion beam etching. These results provide a biostability reference for designing implantable microfabricated devices that feature exposed ceramic films.

Copyright
Linked references
Hide All

This list contains references from the content that can be linked to their source. For a full set of references and notes please see the PDF or HTML where available.

[2] H. Hämmerle , K. Kobuch , K. Kohler , W. Nisch , H. Sachs , and M. Stelzle , “Biostability of micro-photodiode arrays for subretinal implantation,” Biomaterials, 23, 797804 (2002).

[3] Y. Li , R. S. Shawgo , B. Tyler , P. T. Henderson , J. S. Vogel , A. Rosenberg , P. B. Storm , R. Langer , H. Brem , and M. J. Cima , “In vivo release from a drug delivery MEMS device,” J. Controlled Rel., 100, 211219 (2004).

[4] D. J. Edell , “A peripheral nerve information transducer for amputees: long-term multichannel recordings from rabbit peripheral nerves,” IEEE Trans. Biomed. Eng., BME-33, 203214 (1986).

[6] J. W. Osenbach and W. R. Knolle , “Behavior of a-SiN-H and a-SiON:H films in condensed water,” J. Electrochem. Soc., 139, 33463351 (1992).

[7] M. Vogt and R. Hauptmann , “Plasma-deposited passivation layers for moisture and water protection,” Surface Coatings Tech., 74-75, 676681 (1995).

[8] G. Schmitt , J.-W. Schultze , F. Fassbender , G. Buss , H. Lüth , and M. J. Schöning , “Passivation and corrosion of microelectrode arrays,” Electrochimica Acta, 44, 38653883 (1999).

[10] J. M. Anderson , “Inflammation, wound healing, and the foreign body response,” in Biomaterials Science, edited by B. D. Ratner et al, (Academic Press, 1996), pp. 165173.

Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

MRS Online Proceedings Library (OPL)
  • ISSN: -
  • EISSN: 1946-4274
  • URL: /core/journals/mrs-online-proceedings-library-archive
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 2 *
Loading metrics...

Abstract views

Total abstract views: 95 *
Loading metrics...

* Views captured on Cambridge Core between September 2016 - 28th June 2017. This data will be updated every 24 hours.