Hostname: page-component-8448b6f56d-m8qmq Total loading time: 0 Render date: 2024-04-24T09:07:58.819Z Has data issue: false hasContentIssue false

Mass Spectrometric Study of ECR Microwave Plasma Etching of Si3N4 Films

Published online by Cambridge University Press:  25 February 2011

Ming Jin
Affiliation:
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, Manitoba, CanadaR3T 2N2
Kwan C. Kao
Affiliation:
Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, Manitoba, CanadaR3T 2N2
Get access

Abstract

The effects of ion impinging energy on the etching of Si3N4 films in an electron cyclotron resonance (ECR) microwave plasma etching system have been studied. An alternating frequency (10 MHz) bias voltage was used to control the ion impinging energy. The experimental results show that the etching rate in the initial period (less than 3 min) of the etching process is noticeably lower than that in the following period for bias voltage Va > 10 V. The length of the initial period depends on the plasma density. The etching rate in the following period depends on the bias voltage. But the above dependence disappears for Va < 10V. It is found that the surface oxide contribution to the bias effects is negligible. The mass spectrometric measurement of the transient of the etching product SiF4 confirms these bias effects. The effects may be attributed to the ion radiation damage to the subregion lattice even at low ion energies.

Type
Research Article
Copyright
Copyright © Materials Research Society 1992

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Flamm, D.L., Plasma Etching: An Introduction, edited by Manos, D.M. and Flamm, D.L. (Academic, San Diego, 1989) p.165.Google Scholar
2. Parry, P. D., J. Vac. Sci. Technol., 15, 111 (1978).CrossRefGoogle Scholar
3. Nakata, J. and Kajiyama, K., Japn. J. Appl. Phys., 22, 188 (1983)Google Scholar
4. Gibbons, J. G. Hechil, F. O., and Tsurushima, T., Appl. Phys. Left., 15, 117 (1969).Google Scholar
5. Monfret, A. and Bernard, J., Ion Implantation in Semiconductors, (Ruge and Graul Editions, Springer, Berlin. 1971) p. 389.Google Scholar
6. Raby, B. A., J. Vac. Sci. Technol. 15, p.205 (1978).Google Scholar
7. Clarke, R.E., Field, D., Hydes, A.J., Klemperer, D.F., and Seakins, M.J., J. Vac. Sci. Technol., B3, p.1614 (1985).Google Scholar
8. Brandt, W. W., Wagner, J. J., and Honda, T., J. Appl. Phys., 56, p. 1195 (1984).Google Scholar
9. Buchmann, L. M., Heinrich, F., Hoffmann, P., and Janes, J., J. Appl. Phys., 62, p.3635 (1990).Google Scholar
10. Smolinsky, G. and Flamm, D. L., J. Appl. Phys., 50, p.4982 (1979).CrossRefGoogle Scholar
11. Petit, B. and Pelletier, J., Japn. J. Appl. Phys., 26, p.825 (1987).Google Scholar
12. Jin, M. and Kao, K. C., J. Vac. Sci. Technol., B10, p.610 (1992).Google Scholar
13. Wells, A.F., Structure of Inorganic Chemistry, 5th ed. (Clarendon, Oxford, 1984).Google Scholar
14. Sze, S.M., Semiconductor Devices. Physics and Technology, (John Wiley & Sons, New York, 1985) p.360.Google Scholar