Hostname: page-component-8448b6f56d-wq2xx Total loading time: 0 Render date: 2024-04-15T13:49:31.187Z Has data issue: false hasContentIssue false

Response to Allen-Bridson and Pollock

Published online by Cambridge University Press:  15 July 2016

M. Todd Greene*
Affiliation:
Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, Michigan VA/UM Patient Safety Enhancement Program, Ann Arbor, Michigan VA Ann Arbor Healthcare System, Ann Arbor, Michigan
Mohamad G. Fakih
Affiliation:
St. John Hospital and Medical Center, Detroit, Michigan.
Sanjay Saint
Affiliation:
Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, Michigan VA/UM Patient Safety Enhancement Program, Ann Arbor, Michigan VA Ann Arbor Healthcare System, Ann Arbor, Michigan
*
Address correspondence to M. Todd Greene, PhD, MPH, Epidemiologist & Research Investigator, Ann Arbor VA Health System, University of Michigan Health System Division of General Medicine, Program Manager, VA/UM Patient Safety Enhancement Program, 2800 Plymouth Rd., NCRC Building 16, Room 470C, Ann Arbor, MI 48109 (mtgreene@med.umich.edu).
Rights & Permissions [Opens in a new window]

Abstract

Type
Letters to the Editor
Copyright
© 2016 by The Society for Healthcare Epidemiology of America. All rights reserved 

To The Editor—We appreciate the opportunity to respond to Allen-Bridson and Pollock and thank them for their thoughtful letter. We value the data provided in their letter, which helps to illustrate that the overall under-ascertainment of clinically meaningful catheter-associated urinary tract infection (CAUTI) is likely to be lower than we reported in our study, which was purposively constrained to urinary tract-related bloodstream infection. We also recognize that surveillance and clinical definitions are used for different purposes and may not always align.

We would, however, like to raise the following salient points. First, although the Centers for Disease Control and Prevention (CDC) National Health Safety Network (NHSN) CAUTI measures are surveillance based, they are widely used for quality improvement assessment, are tied to compensation, and are often used interchangeably as clinical CAUTI events deemed “potentially preventable.” Thus, it is important for the surveillance measures to be considered clinically relevant.

Second, using historical data containing CAUTIs reported under previous definitions, the CDC reported that the recent change in the CAUTI definition led to a drop in the CAUTI standardized infection ratio to 0.55, with a corresponding reduction in number of attributable events. 1 Many hospitals might mistakenly view this reduction based purely on definitional change as improvement, thereby no longer focusing on inappropriate urinary catheter use. Additionally, the capture of data regarding previously attributed bacteremic CAUTIs through reclassification as central-line bloodstream infection (CLABSIs) denotes a shift in diagnosis and not necessarily an improved diagnosis of CLABSI. The NHSN CLABSI definition is one of exclusion; thus, bacteremia with no other primary source defined by NHSN often ends up being labeled CLABSI. Attributing bacteremia due to urinary tract infection as CLABSI may pose issues because the preventive and therapeutic measures for CAUTI and CLABSI differ.

Third, we agree that with a clinician-based approach, it is difficult to objectively measure for accuracy of diagnosis. However, patients labeled by clinicians as having CAUTI that receive antimicrobials represent a population that includes symptomatic CAUTI and asymptomatic bacteriuria. These are both relevant safety issues for patients in the hospital setting: one is related to device harm and the other is associated with unnecessary antimicrobial harm.

Finally, our conclusion was to consider alternative modifications to the CAUTI surveillance definition; clinician-based diagnosis was provided as one possible example. We further advocate the use of the device utilization ratio as an objective measure that reflects all potential risks (infectious and non-infectious) associated with the urinary catheter.Reference Fakih, Gould and Trautner 2

We applaud the CDC for their efforts in enhancing patient safety. Although we are not promoting clinician-based diagnosis of CAUTI as the panacea, we believe that taking it and other alternatives into consideration have a place in modifying and improving the CAUTI definition. While this process will require several iterations before deriving a surveillance definition that best represents the clinical practice of CAUTI prevention and care, it will be a worthwhile pursuit because it will provide an incredibly powerful tool that can be used to both prevent CAUTI and reduce inappropriate antimicrobial use.

ACKNOWLEDGMENTS

Financial support: This work was supported by a Veterans Affairs Clinical Sciences Research & Development Merit Review Award (grant no. EPID-011-11S).

Potential conflicts of interest: The authors report no conflicts of interest in relation to this letter.

References

REFERENCES

1. National Health Saftety Network e-News. 2015;10(4):6. The Centers for Disease Control and Prevention website. http://www.cdc.gov/nhsn/pdfs/newsletters/nhsn-enewsletter_dec-2015_final.pdf. Published 2015. Accessed June 3, 2016.Google Scholar
2. Fakih, MG, Gould, CV, Trautner, BW, et al. Beyond infection: device utilization ratio as a performance measure for urinary catheter harm. Infect Control Hosp Epidemiol 2016;37:327333.Google Scholar