Hostname: page-component-8448b6f56d-cfpbc Total loading time: 0 Render date: 2024-04-25T05:02:42.706Z Has data issue: false hasContentIssue false

Direct Measurement of Electron Drift Parameters using Depth Sensing Single Carrier CdZnTe Detectors

Published online by Cambridge University Press:  10 February 2011

Z. He
Affiliation:
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109, U.S.A.
G. F. Knoll
Affiliation:
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109, U.S.A.
D. K. Wehe
Affiliation:
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109, U.S.A.
Y. F. Du
Affiliation:
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109, U.S.A.
Get access

Abstract

This paper describes some novel techniques developed for directly measuring the electron mobility μe and mean free drift time Te in wide band gap semiconductors. These methods are based on a newly-developed digital data analysis system, in conjunction with single carrier charge sensing and depth sensing techniques. Compared with conventional methods, the new techniques are easier to implement, do not involve curve fitting, allow the use of high energy γ-rays and are not sensitive to variations in pulse rise time.

Type
Research Article
Copyright
Copyright © Materials Research Society 1998

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Semiconductors for Room Temperature Nuclear Detector Applications, edited by Schlesinger, T.E. and James, R.B., vol.43 of Semiconductors and Semimetals, Academic Press, 1995. pp. 493530.Google Scholar
[2] Hecht, K., Z. Phys. (Germany), vol.77, 1932. p. 235.Google Scholar
[3] Luke, P.N., IEEE Transactions on Nuclear Science, vol.42(4), 1995, p. 207.Google Scholar
[4] He, Z., Knoll, G. F., Wehe, D.K., Rojeski, R., Mastrangelo, C.H., Hammig, M., Barrett, C., Uritani, A., Nuclear Instruments and Methods, vol. A380, 1996. pp. 228231.Google Scholar
[5] He, Z., Knoll, G.F., Wehe, D.K., Miyamoto, J., Nuclear Instruments and Methods, vol. A388, 1997. pp. 180185.Google Scholar
[6] He, Z., Nuclear Instruments and Methods, vol. A365, 1995. pp. 572575.Google Scholar
[7] eV Products, 375 Saxonburg Boulevard, Saxonburg, PA 16056, U.S.A.Google Scholar
[8] Digirad, 7408 Trade Street, San Diego, CA 92121, U.S.A.Google Scholar