Hostname: page-component-8448b6f56d-tj2md Total loading time: 0 Render date: 2024-04-16T23:02:10.045Z Has data issue: false hasContentIssue false

A Study of Localized Corrosion in Al Resulting From The Controlled Introduction of Cl

Published online by Cambridge University Press:  15 February 2011

C. M. Johnson
Affiliation:
Sandia National LaboratoriesP.O. Box 5800 Albuquerque, NM 87185-1056
F. D. Wall
Affiliation:
Sandia National LaboratoriesP.O. Box 5800 Albuquerque, NM 87185-1056
J. C. Barbour
Affiliation:
Sandia National LaboratoriesP.O. Box 5800 Albuquerque, NM 87185-1056
M. A. Martinez
Affiliation:
Sandia National LaboratoriesP.O. Box 5800 Albuquerque, NM 87185-1056
Get access

Abstract

High purity Al samples were implanted with 35 keV Cl+ then polarized in Cl--free electrolyte in order to ascertain corrosion behavior as a function of Cl content. Electrochemical data indicated implant fluences between 5x1015 and 2x1016 Cl+cm-2 resulted in little or no localized attack. Implant fluences of 3x1016 and 5x1016 Cl+cm-2 resulted in significant attack with the severity scaling as a function of implant fluence. The low variability in the behavior of localized corrosion for the 5x1016 Cl+cm-2 sample suggests that this implant dosage may result in a critical Cl- in the sample for pit nucleation. Optical and Electron microscopy images indicated some reactivity associated with lower fluences (1x1016Cl+cm-2), possibly indicating enhanced general dissolution. At high magnification the corrosion was observed to occur outside the implanted boundary through mechanisms of tunneling or altered local chemistry at those sites. The SEM images reveal a form of localized corrosion with a crystalline character.

Type
Research Article
Copyright
Copyright © Materials Research Society 2003

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Szklarska-Smialowska, Z., Pitting Corrosion of Metals (National Association of Corrosion Enginners, Houston, Tex, 1986).Google Scholar
2. Jones, D.A., Principles and Prevention of Corrosion, (Upper Saddle River, NJ, Prentice-Hall, 1996).Google Scholar
3. Bohni, H., Uhlig, H. H., Journal of the Electrochemical Society 116, 906910 (1969).Google Scholar
4. Hoar, T. P., Jacob, W. R., Nature 216, 12991301 (1967).Google Scholar
5. McBee, C. L., Kruger, J., in Localized Corrosion Staehle, R. W., e. al, Eds. (NACE, Houston, 1974) pp. 252.Google Scholar
6. Lin, L. F., Chao, C. Y., Macdonald, D. D., J. Electrochemical Society 128, 11941198 (1981).Google Scholar
7. Sato, N., Electrochimica Acta 16, 1683 (1971).Google Scholar
8. Berzins, A., Lowson, R. T., Mirams, K. J., Australian J. Chemistry 30, 18911903 (1977).Google Scholar
9. Kolics, A., Polkinghorne, J. C., Wieckowski, A., Electrochimica Acta. 43, 26052618 (1998).Google Scholar
10. Atanasoska, L. D., Drazic, D. M., Despic, A. R., Zalar, A., J. Electroanal. Chem. 182, 179186 (1985).Google Scholar
11. Yu, S. Y., O'Grady, W. E., Ramaker, D. E., Natishan, P. M., J. Electrochemical Society 147, 29522958 (2000).Google Scholar