Hostname: page-component-8448b6f56d-dnltx Total loading time: 0 Render date: 2024-04-24T15:44:54.767Z Has data issue: false hasContentIssue false

Photo-Thermal Spectroscopic Imaging of MEMS Structures with Sub-Micron Spatial Resolution

Published online by Cambridge University Press:  12 January 2012

Robert Furstenberg
Affiliation:
U.S. Naval Research Laboratory, Code 6365, Washington, DC 20375, U.S.A.
Christopher A. Kendziora
Affiliation:
U.S. Naval Research Laboratory, Code 6365, Washington, DC 20375, U.S.A.
Michael R. Papantonakis
Affiliation:
U.S. Naval Research Laboratory, Code 6365, Washington, DC 20375, U.S.A.
Viet Nguyen
Affiliation:
U.S. Naval Research Laboratory, Code 6365, Washington, DC 20375, U.S.A.
R. A. McGill
Affiliation:
U.S. Naval Research Laboratory, Code 6365, Washington, DC 20375, U.S.A.
Get access

Abstract

We are developing a new non-contact and non-destructive imaging technique which requires no sample preparation and provides similar content information as FTIR or Raman spectroscopy while being immune to fluorescence and offers a potentially faster scan rate and/or higher spatial resolution. It utilizes photo-thermal heating of the sample with a quantum cascade laser (or other suitable infrared laser) and measuring the resulting increase in thermal emissions by either an infrared (IR) detector or a laser probe consisting of a visible laser reflected from the sample. The latter case allows for further increases in the spatial resolution from ∼10 μm to ∼1 μm or better, with suitable experimental conditions. Since the thermal emission signal is proportional to the absorption coefficient, by tuning the wavelength of the IR laser we can directly measure the IR spectrum of the sample. By raster scanning over the surface of the sample we can obtain maps of the chemical composition of the sample surface. We demonstrate this technique by imaging the surface of a micro-fabricated flow-through chemical vapor preconcentrator consisting of a silicon frame and a suspended-perforated polyimide membrane with a pair of platinum heater traces, coated with a custom sorbent polymer for selective sorption of analyte. We measure the spatial resolution of our photo-thermal imaging system as well as discuss the conditions under which the spatial resolution can be further increased from the far-field diffraction limited resolution given by the combination of the imaging optic and IR excitation laser wavelength.

Type
Research Article
Copyright
Copyright © Materials Research Society 2012

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Tam, A. C., in Photo-thermal Investigations of Solids and Fluids, edited by Sell, J. A., (Academic Press Inc., San Diego, CA, 1988).Google Scholar
2. Furstenberg, R., Kendziora, C. A., Stepnowski, J., Stepnowski, S. V., Rake, M., Papantonakis, M. R., Nguyen, V., Hubler, G. K. and McGill, R. A., Appl. Phys. Lett., 93(22) (2008).Google Scholar
3. Martin, M., Crain, M., Walsh, K., McGill, R. A., Houser, E., Stepnowski, J., Stepnowski, S., Wu, H. D., Ross, S., Sensors And Actuators B - Chemical 126, 447454 (2007).Google Scholar
4. Higgins, B. A., Simonson, D. L., Houser, E. J. Kohl, J. G. and McGill, R. A., J. Pol. Sci. Part A. 48, 30003009 (2010) .Google Scholar