Hostname: page-component-8448b6f56d-sxzjt Total loading time: 0 Render date: 2024-04-23T21:00:15.163Z Has data issue: false hasContentIssue false

Study of the 14C-Contamination Potential of C-Impurities in CuO and Fe

Published online by Cambridge University Press:  18 July 2016

Kurt Vandeputte
Affiliation:
Department of Analytical Chemistry, University of Ghent, Proeftuinstraat 86, B-9000 Ghent, Belgium
Luc Moens
Affiliation:
Department of Analytical Chemistry, University of Ghent, Proeftuinstraat 86, B-9000 Ghent, Belgium
Richard Dams
Affiliation:
Department of Analytical Chemistry, University of Ghent, Proeftuinstraat 86, B-9000 Ghent, Belgium
Johannes Van Der Plicht
Affiliation:
Center for Isotope Research, University of Groningen, Nijenborgh 4, NL-9747 AG Groningen The Netherlands
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The carbon concentration in CuO and iron was determined by isolating C. The values were in agreement with results reported in other studies. Contaminating carbon from CuO and Fe was transformed to AMS targets and measured for 14C. C-traces in CuO were shown to be the major contribution to the 14C sample processing blank. In addition, there is a significant variability in the 14C content of CuO observed between different production batches. The combined contamination potential of CuO and Fe was found to be 4.47–8.92 μg recent carbon, whereas the more realistic estimate for AMS-target preparation conditions ranged between 1.63 and 3.24 μg recent carbon, depending on the 14C level in CuO.

Type
Part 1: Methods
Copyright
Copyright © The American Journal of Science 

References

Aerts-Bijma, A. Th., Meijer, H. A. J. and van der Plicht, J. 1997 AMS sample handling in Groningen. Nuclear Instruments and Methods in Physics Research B123 221–225.Google Scholar
Arnold, M., Bard, E., Maurice, P. and Duplessy, J.-C. 1987 14C dating with the Gif-sur-Yvette tandetron accelerator: Status report. Nuclear Instruments and Methods in Physics Research B29: 120123.Google Scholar
Beukens, R. P. 1993 Radiocarbon accelerator mass spectrometry: Background and contamination. Nuclear Instruments and Methods in Physics Research B79: 620623.Google Scholar
Boutton, T. W. 1991 Stable carbon isotope ratios of natural materials: I. Sample preparation and mass spectrometric analysis. In Coleman, D. C. and Fry, B., eds., Carbon Isotope Techniques. San Diego, Academic Press: 155172.CrossRefGoogle Scholar
Currie, L. A., Klouda, G. A., Klinedinst, D. B., Sheffield, A. E., Jull, A. J. T., Donahue, D. J. and Connolly, M. V. 1994 Fossil- and bio-mass combustion: C-14 for source identification, chemical tracer development and model validation. Nuclear Instruments and Methods in Physics Research B92: 404409.Google Scholar
de Neve, K., Strijkmans, K., Vandeputte, K. and Dams, R. 1997 Deuteron activation analysis for the determination of carbon in iron and copper oxide, reagents for 14C-dating by accelerator mass spectrometry. Journal of Radioanalytical and Nuclear Chemistry 221(1): 7983.Google Scholar
Donahue, D. J., Jull, A. J. T. and Toolin, L. J. 1990 Radiocarbon measurements at the university of Arizona AMS facility. Nuclear Instruments and Methods in Physics Research B52: 224228.Google Scholar
Gulliksen, S. and Thomsen, M. S. 1992 Examination of background contamination levels for gas counting and AMS target preparation in Trondheim. In Long, A. and Kra, R. S., eds., Proceedings of the 14th International 14C Conference. Radiocarbon 34(3): 312317.CrossRefGoogle Scholar
Gurfinkel, D. M. 1987 An assessment of laboratory contamination at the Isotrace radiocarbon facility. Radiocarbon 29(3): 335346.Google Scholar
Hedges, R. E. M., Law, I. A., Bronk Ramsey, C. and Housley, R. A. 1989 The Oxford accelerator mass spectrometry facility: Technical developments in routine dating. Archaeometry 21(2): 99113.Google Scholar
IAEA 1993 Reference and intercomparison materials for stable isotopes of light elements. Proceedings of a consultants meeting held in Vienna, 1–3/12/'93. IAEA-TECDOC-825.Google Scholar
Jull, A. J. T., Lifton, N., Phillips, W. M. and Quade, J. 1994 Studies of the production rate of cosmic-ray produced 14C in rock surfaces. Nuclear Instruments and Methods in Physics Research B92: 308310.Google Scholar
Klinedinst, D. B., McNichol, A. P., Currie, L. A., Schneider, R. J., Klouda, G. A., von Reden, K. F., Verkouteren, R. M. and Jones, G. A. 1994 Comparative study of Fe-C bead and graphite target performance with the National Ocean Science AMS (NOSAMS) facility recombinator ion source. Nuclear Instruments and Methods in Physics Research B92: 166171.Google Scholar
Strijkmans, K. 1994 Charged particle activation analysis. In Alfassi, Z. B., ed., Chemical Analysis by Nuclear Methods. Chichester, John Wiley & Sons Ltd.: 215251.Google Scholar
Verkouteren, R. M., Klinedinst, D. B. and Currie, L. A. 1997 Iron-manganese system for preparation of radiocarbon AMS targets: Characterization of procedural chemical-isotopic blanks and fractionation. Radiocarbon 39(3): 269283.CrossRefGoogle Scholar
Verkouteren, R. M., Klouda, G. A., Currie, L. A., Donahue, D. J., Jull, A. J. T. and Linick, T. W. 1987 Preparation of microgram samples on iron wool for radiocarbon analysis via accelerator mass spectrometry: A closed-system approach. Nuclear Instruments and Methods in Physics Research B29: 4144.CrossRefGoogle Scholar
Vogel, J. S., Nelson, D. E. and Southon, J. R. 1987 14C background levels in an accelerator mass spectrometry system. Radiocarbon 29(3): 323333.Google Scholar
Vogel, J. S., Southon, J. R., Nelson, D. E. and Brown, T. A. 1984 Performance of catalytically condensed carbon for use in accelerator mass spectrometry. Nuclear Instruments and Methods in Physics Research B5: 289293.Google Scholar
Wand, J. O., Gillespie, R. and Hedges, R. E. M. 1984 Sample preparation for accelerator-based Radiocarbon dating. Journal of Archaeological Science 10: 159163.Google Scholar