To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Automated dispensers that dilute concentrated disinfectants with water are commonly used but can malfunction. We provide proof-of-principle that incorporating indicators into wipe products could be an effective method to provide environmental services staff with real-time visual indication that disinfectants are present and at correct concentrations with every use.
In an observational study, healthcare personnel often entered contact precautions rooms without contacting patients or the environment. An approach requiring gloves and gowns based on actual contacts rather than for all room entries would reduce personal protective equipment donning and doffing time, cost, and carbon footprint by more than half.
Automated dispensers that dilute concentrated disinfectants with water are commonly used in healthcare facilities. In a point-prevalence product evaluation, 9 of 10 (90%) hospitals using dilutable disinfectants had 1 or more malfunctioning dispensers. Twenty-nine of 107 (27.1%) systems dispensed product with lower-than-expected concentrations, including 15 (14.0%) with no detectable disinfectant.
To investigate a cluster of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infections in employees working on 1 floor of a hospital administration building.
Methods:
Contact tracing was performed to identify potential exposures and all employees were tested for SARS-CoV-2. Whole-genome sequencing was performed to determine the relatedness of SARS-CoV-2 samples from infected personnel and from control cases in the healthcare system with coronavirus disease 2019 (COVID-19) during the same period. Carbon dioxide levels were measured during a workday to assess adequacy of ventilation; readings >800 parts per million (ppm) were considered an indication of suboptimal ventilation. To assess the potential for airborne transmission, DNA-barcoded aerosols were released, and real-time polymerase chain reaction was used to quantify particles recovered from air samples in multiple locations.
Results:
Between December 22, 2020, and January 8, 2021, 17 coworkers tested positive for SARS-CoV-2, including 13 symptomatic and 4 asymptomatic individuals. Of the 5 cluster SARS-CoV-2 samples sequenced, 3 were genetically related, but these employees denied higher-risk contacts with one another. None of the sequences from the cluster were genetically related to the 17 control sequences of SARS-CoV-2. Carbon dioxide levels increased during a workday but never exceeded 800 ppm. DNA-barcoded aerosol particles were dispersed from the sites of release to locations throughout the floor; 20% of air samples had >1 log10 particles.
Conclusions:
In a hospital administration building outbreak, sequencing of SARS-CoV-2 confirmed transmission among coworkers. Transmission occurred despite the absence of higher-risk exposures and in a setting with adequate ventilation based on monitoring of carbon dioxide levels.
On coronavirus disease 2019 (COVID-19) wards, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid was frequently detected on high-touch surfaces, floors, and socks inside patient rooms. Contamination of floors and shoes was common outside patient rooms on the COVID-19 wards but decreased after improvements in floor cleaning and disinfection were implemented.
In a culture survey, we found that 42% of hospital privacy curtains were contaminated with vancomycin-resistant enterococci, 22% with methicillin-resistant Staphylococcus aureus, and 4% with Clostridium difficile. Hand imprint cultures demonstrated that these pathogens were easily acquired on hands. Hospital curtains are a potential source for dissemination of healthcare-associated pathogens.
Hospital-acquired Legionella pneumonia has a fatality rate of 28%, and the source is the water distribution system. Two prevention strategies have been advocated. One approach to prevention is clinical surveillance for disease without routine environmental monitoring. Another approach recommends environmental monitoring even in the absence of known cases of Legionella pneumonia. We determined the Legionella colonization status of water systems in hospitals to establish whether the results of environmental surveillance correlated with discovery of disease. None of these hospitals had previously experienced endemic hospital-acquired Legionella pneumonia.
Design.
Cohort study.
Setting.
Twenty US hospitals in 13 states.
Interventions.
Hospitals performed clinical and environmental surveillance for Legionella from 2000 through 2002. All specimens were shipped to the Special Pathogens Laboratory at the Veterans Affairs Pittsburgh Medical Center.
Results.
Legionella pneumophila and Legionella anisa were isolated from 14 (70%) of 20 hospital water systems. Of 676 environmental samples, 198 (29%) were positive for Legionella species. High-level colonization of the water system (30% or more of the distal outlets were positive for L. pneumophila) was demonstrated for 6 (43%) of the 14 hospitals with positive findings. L. pneumophila serogroup 1 was detected in 5 of these 6 hospitals, whereas 1 hospital was colonized with L. pneumophila serogroup 5. A total of 633 patients were evaluated for Legionella pneumonia from 12 (60%) of the 20 hospitals: 377 by urinary antigen testing and 577 by sputum culture. Hospital-acquired Legionella pneumonia was identified in 4 hospitals, all of which were hospitals withL. pneumophila serogroup 1 found in 30% or more of the distal outlets. No cases of disease due to other serogroups or species (L. anisa) were identified.
Conclusion.
Environmental monitoring followed by clinical surveillance was successful in uncovering previously unrecognized cases of hospital-acquired Legionella pneumonia.
We examined the frequency of acquisition of bacterial pathogens on investigators' hands after contacting environmental surfaces near hospitalized patients. Hand imprint cultures were positive for one or more pathogens after contacting surfaces near 34 (53%) of 64 study patients, with Staphylococcus aureus and vancomycin-resistant Enterococcus being the most common isolates.
Antianaerobic antibiotic therapy promotes persistent high-density growth of vancomycin-resistant enterococci (VRE) in the stool of colonized patients. We tested the hypothesis that antibiotic regimens with potent antianaerobic activity promote overgrowth of coexisting antibiotic-resistant, gram-negative bacilli in the stool of VRE-colonized patients.
Design:
Eight-month prospective study examining the effect of antibiotic therapy on the stool density of gram-negative bacilli resistant to ceftazidime, ciprofloxacin, or piperacillin/tazobactam.
Setting:
A Department of Veterans Affairs medical center including an acute care hospital and nursing home.
Patients:
All VRE-colonized patients with at least 3 stool samples available for analysis.
Results:
One-hundred forty stool samples were obtained from 37 study patients. Forty-nine (61%) of 80 stool samples obtained during therapy with an antianaerobic regimen were positive for an antibiotic-resistant, gram-negative bacillus, whereas only 14 (23%) of 60 samples obtained 4 or more weeks after completion of such therapy were positive (P < .001). Twenty-four (65%) of the 37 patients had one or more stool cultures positive for a gram-negative bacillus resistant to ciprofloxacin, ceftazidime, or piperacillin/tazobactam. The density of these organisms was higher during therapy with antianaerobic regimens than in the absence of such therapy for at least 2 weeks (mean ± standard deviation, 5.6 ± 1.4 and 3.9 ± 0.71 log10 organisms/g; P < .001).
Conclusion:
Limiting the use of antianaerobic antibiotics in VRE-colonized patients may reduce the density of colonization with coexisting antibiotic-resistant, gram-negative bacilli.
We examined the point prevalence of undetected vancomycin-resistant Enterococcus (VRE) stool colonization in an institution that screens stool samples submitted for Clostridium difficile testing. Of 112 patients not known to be colonized, 10 (9%) had rectal VRE colonization. A prospective algorithm was effective for identification of colonized patients.