To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Positive symptoms are a useful predictor of aggression in schizophrenia. Although a similar pattern of abnormal brain structures related to both positive symptoms and aggression has been reported, this observation has not yet been confirmed in a single sample.
Method
To study the association between positive symptoms and aggression in schizophrenia on a neurobiological level, a prospective meta-analytic approach was employed to analyze harmonized structural neuroimaging data from 10 research centers worldwide. We analyzed brain MRI scans from 902 individuals with a primary diagnosis of schizophrenia and 952 healthy controls.
Results
The result identified a widespread cortical thickness reduction in schizophrenia compared to their controls. Two separate meta-regression analyses revealed that a common pattern of reduced cortical gray matter thickness within the left lateral temporal lobe and right midcingulate cortex was significantly associated with both positive symptoms and aggression.
Conclusion
These findings suggested that positive symptoms such as formal thought disorder and auditory misperception, combined with cognitive impairments reflecting difficulties in deploying an adaptive control toward perceived threats, could escalate the likelihood of aggression in schizophrenia.
Influenza is a major concern for Emergency Medical Services (EMS); EMS workers’ (EMS-Ws) vaccination rates remain low despite promotion. Determinants of vaccination for seasonal influenza (SI) or pandemic influenza (PI) are unknown in this setting.
Hypothesis
The influence of the H1N1 pandemic on EMS-W vaccination rates, differences between SI and PI vaccination rates, and the vaccination determinants were investigated.
Methods
A survey was conducted in 2011 involving 65 Swiss EMS-Ws. Socio-professional data, self-declared SI/PI vaccination status, and motives for vaccine refusal or acceptation were collected.
Results
Response rate was 95%. The EMS-Ws were predominantly male (n=45; 73%), in good health (87%), with a mean age of 36 (SD=7.7) years. Seventy-four percent had more than six years of work experience. Self-declared vaccination rates were 40% for both SI and PI (PI+/SI+), 19% for PI only (PI+/SI-), 1.6% for SI only (PI-/SI+), and 39% were not vaccinated against either (PI-/SI-). Women’s vaccination rates specifically were lower in all categories but the difference was not statistically significant. During the previous three years, 92% of PI+/SI+ EMS-Ws received at least one SI vaccination; it was 8.3% in the case of PI-/SI- (P=.001) and 25% for PI+/SI- (P=.001). During the pandemic, SI vaccination rate increased from 26% during the preceding year to 42% (P=.001). Thirty percent of the PI+/SI+ EMS-Ws declared that they would not get vaccination next year, while this proportion was null for the PI-/SI- and PI+/SI- groups. Altruism and discomfort induced by the surgical mask required were the main motivations to get vaccinated against PI. Factors limiting PI or SI vaccination included the option to wear a mask, avoidance of medication, fear of adverse effects, and concerns about safety and effectiveness.
Conclusion
Average vaccination rate in this study’s EMS-Ws was below recommended values, particularly for women. Previous vaccination status was a significant determinant of PI and future vaccinations. The new mask policy seemed to play a dual role, and its net impact is probably limited. This population could be divided in three groups: favorable to all vaccinations; against all, even in a pandemic context; and ambivalent with a “pandemic effect.” These results suggest a consistent vaccination pattern, only altered by exceptional circumstances.
MoserA ,MabireC ,HugliO ,DorriboV ,ZanettiG ,Lazor-BlanchetC ,CarronPN . Vaccination Against Seasonal or Pandemic Influenza in Emergency Medical Services. Prehosp Disaster Med. 2016;31(2):155–162.
The risk of carrying methicillin-resistant Staphylococcus aureus (MRSA) is higher among nursing home (NH) residents than in the general population. However, control strategies are not clearly defined in this setting. In this study, we compared the impact of standard precautions either alone (control) or combined with screening of residents and decolonization of carriers (intervention) to control MRSA in NHs.
DESIGN
Cluster randomized controlled trial
SETTING
NHs of the state of Vaud, Switzerland
PARTICIPANTS
Of 157 total NHs in Vaud, 104 (67%) participated in the study.
INTERVENTION
Standard precautions were enforced in all participating NHs, and residents underwent MRSA screening at baseline and 12 months thereafter. All carriers identified in intervention NHs, either at study entry or among newly admitted residents, underwent topical decolonization combined with environmental disinfection, except in cases of MRSA infection, MRSA bacteriuria, or deep skin ulcers.
RESULTS
NHs were randomly allocated to a control group (51 NHs, 2,412 residents) or an intervention group (53 NHs, 2,338 residents). Characteristics of NHs and residents were similar in both groups. The mean screening rates were 86% (range, 27%–100%) in control NHs and 87% (20%–100%) in intervention NHs. Prevalence of MRSA carriage averaged 8.9% in both control NHs (range, 0%–43%) and intervention NHs (range, 0%–38%) at baseline, and this rate significantly declined to 6.6% in control NHs and to 5.8% in intervention NHs after 12 months. However, the decline did not differ between groups (P=.66).
CONCLUSION
Universal screening followed by decolonization of carriers did not significantly reduce the prevalence of the MRSA carriage rate at 1 year compared with standard precautions.
Surveillance of nosocomial bloodstream infection (BSI) is recommended, but time-consuming. We explored strategies for automated surveillance.
Methods.
Cohort study. We prospectively processed microbiological and administrative patient data with computerized algorithms to identify contaminated blood cultures, community-acquired BSI, and hospital-acquired BSI and used algorithms to classify the latter on the basis of whether it was a catheter-associated infection. We compared the automatic classification with an assessment (71% prospective) of clinical data.
Setting.
An 850-bed university hospital.
Participants.
All adult patients admitted to general surgery, internal medicine, a medical intensive care unit, or a surgical intensive care unit over 3 years.
Results.
The results of the automated surveillance were 95% concordant with those of classical surveillance based on the assessment of clinical data in distinguishing contamination, community-acquired BSI, and hospital-acquired BSI in a random sample of 100 cases of bacteremia. The two methods were 74% concordant in classifying 351 consecutive episodes of nosocomial BSI with respect to whether the BSI was catheter-associated. Prolonged episodes of BSI, mostly fungemia, that were counted multiple times and incorrect classification of BSI clinically imputable to catheter infection accounted for 81% of the misclassifications in automated surveillance. By counting episodes of fungemia only once per hospital stay and by considering all cases of coagulase-negative staphylococcal BSI to be catheter-related, we improved concordance with clinical assessment to 82%. With these adjustments, automated surveillance for detection of catheter-related BSI had a sensitivity of 78% and a specificity of 93%; for detection of other types of nosocomial BSI, the sensitivity was 98% and the specificity was 69%.
Conclusion.
Automated strategies are convenient alternatives to manual surveillance of nosocomial BSI.
A burn patient was infected with Acinetobacter baumannii on transfer to the hospital after a terrorist attack. Two patients experienced cross-infection. Environmental swab samples were negative for A. baumannii. Six months later, the bacteria reemerged in 6 Patients. Environmental swab samples obtained at this time were inoculated into a minimal mineral broth, and culture results showed widespread contamination. No case of infection occurred after closure of the unit for disinfection.
In 1998, a study in the intensive care unit (ICU) of our institution suggested possible transmission of Pseudomonas aeruginosa from faucet to patient and from patient to patient. Infection-control measures were implemented to reduce the degree of P. aeruginosa colonization in faucets, to reduce the use of faucet water in certain patient care procedures, and to reduce the rate of transmission from patient to patient.
Objective.
To evaluate the effect of the control measures instituted in 1999 to prevent P. aeruginosa infection and colonization in ICU patients.
A 870-bed, university-affiliated, tertiary care teaching hospital.
Methods.
The investigation was performed in a manner identical to the 1998 investigation. ICU patients with a clinical specimen positive for P. aeruginosa were identified prospectively. Swab specimens from the inner part of the ICU faucets were obtained for the culture on 9 occasions between September 1997 and December 2000. All patients and environmental isolates were typed by pulsed-field gel electrophoresis (PFGE).
Results.
Compared with the 1998 study, in 2000 we found that the annual incidence of ICU patients colonized or infected with P. aeruginosa had decreased by half (26.6 patients per 1,000 admissions in 2000 vs 59.0 patients per 1,000 admissions in 1998), although the populations of patients were comparable. This decrease was the result of the decreased incidence of cases in which an isolate had a PFGE pattern identical to that of an isolate from a faucet (7.0 cases per 1,000 admissions in 2000, vs 23.6 per 1,000 admissions in 1998) or from another patient (6.5 cases per 1,000 admissions in 2000 vs 16.5 cases per 1,000 admissions in 1998), whereas the incidence of cases in which the isolate had a unique PFGE pattern remained nearly unchanged (13.1 cases per 1,000 admissions in 2000 vs 15.6 cases per 1,000 admissions in 1998).
Conclusions.
These results suggest that infection control measures were effective in decreasing the rate of P. aeruginosa colonization and infection in ICU patients, confirming that P. aeruginosa strains were of exogenous origin in a substantial proportion of patients during the preintervention period.
To assess the impact of an automated intraoperative alert to redose prophylactic antibiotics in prolonged cardiac operations.
Design:
Randomized, controlled, evaluator-blinded trial.
Setting:
University-affiliated hospital.
Patients:
Patients undergoing cardiac surgery that lasted more than 4 hours after the preoperative administration of cefazolin, unless they were receiving therapeutic antibiotics at the time of surgery.
Intervention:
Randomization to an audible and visual reminder on the operating room computer console at 225 minutes after the administration of preoperative antibiotics (reminder group, n = 137) or control (n = 136). After another 30 minutes, the circulating nurse was required to indicate whether a follow-up dose of antibiotics had been administered.
Results:
Intraoperative redosing was significantly more frequent in the reminder group (93 of 137; 68%) than in the control group (55 of 136; 40%) (adjusted odds ratio, 3.31; 95% confidence interval, 1.97 to 5.56; P < .0001). The impact of the reminder was even greater when compared with the 6 months preceding the study period (129 of 480; 27%; P < .001), suggesting some spillover effect on the control group. Redosing was formally declined for 19 of the 44 patients in the reminder group without redosing. The rate of surgical-site infection in the reminder group (5 of 137; 4%) was similar to that in the control group (8 of 136; 6%; P = .42), but significantly lower than that in the pre-study period (48 of 480; 10%; P = .02).
Conclusion:
The use of an automatic reminder system in the operating room improved compliance with guidelines on perioperative antibiotic prophylaxis.