We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To measure SARS-CoV-2 anti-nucleocapsid (anti-N) antibody seropositivity among healthcare personnel (HCP) without a history of COVID-19 and to identify HCP characteristics associated with seropositivity.
Design:
Prospective cohort study from September 22, 2020, to March 3, 2022.
Setting:
A tertiary care academic medical center.
Participants:
727 HCP without prior positive SARS-CoV-2 PCR testing were enrolled; 559 HCP successfully completed follow-up.
Methods:
At enrollment and follow-up 1–6 months later, HCP underwent SARS-CoV-2 anti-N testing and were surveyed on demographics, employment information, vaccination status, and COVID-19 symptoms and exposures.
Results:
Of 727 HCP enrolled, 27 (3.7%) had a positive SARS-CoV-2 anti-N test at enrollment. Seropositive HCPs were more likely to have a household exposure to COVID-19 in the past 30 days (OR 7.92, 95% CI 2.44–25.73), to have had an illness thought to be COVID-19 (4.31, 1.94–9.57), or to work with COVID-19 patients more than half the time (2.09, 0.94–4.77). Among 559 HCP who followed-up, 52 (9.3%) had a positive SARS-CoV-2 anti-N antibody test result. Seropositivity at follow-up was associated with community/household exposures to COVID-19 within the past 30 days (9.50, 5.02–17.96; 2.90, 1.31–6.44), having an illness thought to be COVID-19 (8.24, 4.44–15.29), and working with COVID-19 patients more than half the time (1.50, 0.80–2.78).
Conclusions:
Among HCP without prior positive SARS-CoV-2 testing, SARS-CoV-2 anti-N seropositivity was comparable to that of the general population and was associated with COVID-19 symptomatology and both occupational and non-occupational exposures to COVID-19.
To determine the prevalence of severe acute respiratory coronavirus virus 2 (SARS-CoV-2) IgG nucleocapsid (N) antibodies among healthcare personnel (HCP) with no prior history of COVID-19 and to identify factors associated with seropositivity.
Design:
Prospective cohort study.
Setting:
An academic, tertiary-care hospital in St. Louis, Missouri.
Participants:
The study included 400 HCP aged ≥18 years who potentially worked with coronavirus disease 2019 (COVID-19) patients and had no known history of COVID-19; 309 of these HCP also completed a follow-up visit 70–160 days after enrollment. Enrollment visits took place between September and December 2020. Follow-up visits took place between December 2020 and April 2021.
Methods:
At each study visit, participants underwent SARS-CoV-2 IgG N-antibody testing using the Abbott SARS-CoV-2 IgG assay and completed a survey providing information about demographics, job characteristics, comorbidities, symptoms, and potential SARS-CoV-2 exposures.
Results:
Participants were predominately women (64%) and white (79%), with median age of 34.5 years (interquartile range [IQR], 30–45). Among the 400 HCP, 18 (4.5%) were seropositive for IgG N-antibodies at enrollment. Also, 34 (11.0%) of 309 were seropositive at follow-up. HCP who reported having a household contact with COVID-19 had greater likelihood of seropositivity at both enrollment and at follow-up.
Conclusions:
In this cohort of HCP during the first wave of the COVID-19 pandemic, ∼1 in 20 had serological evidence of prior, undocumented SARS-CoV-2 infection at enrollment. Having a household contact with COVID-19 was associated with seropositivity.
Dental healthcare personnel (DHCP) are at high risk of exposure to coronavirus disease 2019 (COVID-19). We sought to identify how DHCP changed their use of personal protective equipment (PPE) as a result of the COVID-19 pandemic, and to pilot an educational video designed to improve knowledge of proper PPE use.
Design:
The study comprised 2 sets of semistructured qualitative interviews.
Setting:
The study was conducted in 8 dental clinics in a Midwestern metropolitan area.
Participants:
In total, 70 DHCP participated in the first set of interviews; 63 DHCP participated in the second set of interviews.
Methods:
In September–November 2020 and March–October 2021, we conducted 2 sets of semistructured interviews: (1) PPE use in the dental community during COVID-19, and (2) feedback on the utility of an educational donning and doffing video.
Results:
Overall, 86% of DHCP reported having prior training. DHCP increased the use of PPE during COVID-19, specifically N95 respirators and face shields. DHCP reported real-world challenges to applying infection control methods, often resulting in PPE modification and reuse. DHCP reported double masking and sterilization methods to extend N95 respirator use. Additional challenges to PPE included shortages, comfort or discomfort, and compatibility with specialty dental equipment. DHCP found the educational video helpful and relevant to clinical practice. Fewer than half of DHCP reported exposure to a similar video.
Conclusions:
DHCP experienced significant challenges related to PPE access and routine use in dental clinics during the COVID-19 pandemic. An educational video improved awareness and uptake of appropriate PPE use among DHCP.
In this prospective, longitudinal study, we examined the risk factors for severe acute respiratory coronavirus virus 2 (SARS-CoV-2) infection among a cohort of chronic hemodialysis (HD) patients and healthcare personnel (HCPs) over a 6-month period. The risk of SARS-CoV-2 infection among HD patients and HCPs was consistently associated with a household member having SARS-CoV-2 infection.
In a prospective cohort of healthcare personnel (HCP), we measured severe acute respiratory syndrome coronavirus virus 2 (SARS-CoV-2) nucleocapsid IgG antibodies after SARS-CoV-2 infection. Among 79 HCP, 68 (86%) were seropositive 14–28 days after their positive PCR test, and 54 (77%) of 70 were seropositive at the 70–180-day follow-up. Many seropositive HCP (95%) experienced an antibody decline by the second visit.
Aeroacoustic measurements and analysis have been made for an unshrouded rotor partially immersed in a planar equilibrium turbulent boundary layer at low Mach number. This configuration provides an idealized model of inflow distortion effects seen when a rotor is mounted adjacent to the hull or fuselage of a vehicle. At low and moderate thrust conditions, the rotor produces broadband noise organized into haystacks produced by large eddies of the ingested turbulence being cut multiple times by successive rotor blades. At high thrust, however, the acoustic signature changes and becomes louder and more tonal. This change is accompanied by separation of the boundary layer from the wall in the vicinity of the rotor blade disk. The separation region is highly unsteady and populated by intense vortex structures. Acoustic analysis suggests that blade–vortex interactions with these structures are the source of the additional tonal noise at high thrust.
Toxic anterior segment syndrome (TASS), a complication of cataract surgery, is a sterile inflammation of the anterior chamber of the eye. An outbreak of TASS was recognized at an outpatient surgical center and its affiliated hospital in December 2002.
Methods.
Medical records of patients who underwent cataract surgery during the outbreak were reviewed, and surgical team members who participated in the operations were interviewed. Potential causes of TASS were identified and eliminated. Feedwater from autoclave steam generators and steam condensates were analyzed by use of spectroscopy and ion chromatography.
Results.
During the outbreak, 8 (38%) of 21 cataract operations were complicated by TASS, compared with 2 (0.07%) of 2,713 operations performed from January 1996 through November 2002. Results of an initial investigation suggested that cataract surgical equipment may have been contaminated by suboptimal equipment reprocessing or as a result of personnel changes. The frequency of TASS decreased (1 of 44 cataract operations) after reassignment of personnel and revision of equipment reprocessing procedures. Further investigation identified the presence of impurities (eg, sulfates, copper, zinc, nickel, and silica) in autoclave steam moisture, which was attributed to improper maintenance of the autoclave steam generator in the outpatient surgical center. When impurities in autoclave steam moisture were eliminated, no cases of TASS were observed after more than 1,000 cataract operations.
Conclusion.
Suboptimal reprocessing of cataract surgical equipment may evolve over time in busy, multidisciplinary surgical centers. Clinically significant contamination of surgical equipment may result from inappropriate maintenance of steam sterilization systems. Standardization of protocols for reprocessing of cataract surgical equipment may prevent outbreaks of TASS and may be of assistance during outbreak investigations.