We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Movement disorders associated with exposure to antipsychotic drugs are common and stigmatising but underdiagnosed.
Aims
To develop and evaluate a new clinical procedure, the ScanMove instrument, for the screening of antipsychotic-associated movement disorders for use by mental health nurses.
Method
Item selection and content validity assessment for the ScanMove instrument were conducted by a panel of neurologists, psychiatrists and a mental health nurse, who operationalised a 31-item screening procedure. Interrater reliability was measured on ratings for 30 patients with psychosis from ten mental health nurses evaluating video recordings of the procedure. Criterion and concurrent validity were tested comparing the ScanMove instrument-based rating of 13 mental health nurses for 635 community patients from mental health services with diagnostic judgement of a movement disorder neurologist based on the ScanMove instrument and a reference procedure comprising a selection of commonly used rating scales.
Results
Interreliability analysis showed no systematic difference between raters in their prediction of any antipsychotic-associated movement disorders category. On criterion validity testing, the ScanMove instrument showed good sensitivity for parkinsonism (90%) and hyperkinesia (89%), but not for akathisia (38%), whereas specificity was low for parkinsonism and hyperkinesia, and moderate for akathisia.
Conclusions
The ScanMove instrument demonstrated good feasibility and interrater reliability, and acceptable sensitivity as a mental health nurse-administered screening tool for parkinsonism and hyperkinesia.
Declaration of interest
None.