Hostname: page-component-848d4c4894-p2v8j Total loading time: 0.001 Render date: 2024-06-01T09:02:17.516Z Has data issue: false hasContentIssue false

Preincision versus postincision frequent door openings during total joint arthroplasty

Published online by Cambridge University Press:  12 January 2022

Danielle N. Davis*
Affiliation:
University of Colorado School of Medicine, Aurora, Colorado
Lexie K. Ross
Affiliation:
University of Colorado School of Medicine, Aurora, Colorado
Zihan Feng
Affiliation:
University of Colorado School of Medicine, Aurora, Colorado
Ryan Imber
Affiliation:
University of Colorado School of Medicine, Aurora, Colorado
Craig Hogan
Affiliation:
University of Colorado Health, Aurora, Colorado
Heather L. Young
Affiliation:
Denver Health, Denver, Colorado
*
Author for correspondence: Danielle N. Davis, 1420 Bear Cloud Drive, Colorado Springs, CO80919. E-mail: Danielle.n.davis@cuanschutz.edu

Abstract

Type
Research Brief
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction in any medium, provided the original article is properly cited.
Copyright
© The Author(s), 2022. Published by Cambridge University Press on behalf of The Society for Healthcare Epidemiology of America

Surgical site infections (SSIs) are a serious complication of total hip and total knee arthroplasty. Reference Lynch, Englesbe and Sturm1 Risk factors for developing SSIs can be considered in 4 categories: (1) patient-related factors, (2) surgical technique, (3) operating room environment, Reference Pokrywka and Byers2 and (4) postoperative care. Of these factors, the operating room environment stands out as the factor that healthcare professionals have the most control over. Frequent operating room door openings are believed to disrupt laminar airflow Reference Perez, Holloway and Ehrenfeld3 and positive pressure. Reference Mears, Blanding and Belkoff4 Several studies have implicated frequent door openings in the operating room with higher rates of airborne contamination Reference Perez, Holloway and Ehrenfeld3,Reference Andersson, Bergh, Karlsson, Eriksson and Nilsson5 and subsequently increased rates of SSIs. Reference Roth, Juchler, Dangel, Eckstein, Battegay and Widmer6

High rates of door openings during total hip and total knee arthroplasty have been previously reported in the literature. Reference Lynch, Englesbe and Sturm1,Reference Andersson, Bergh, Karlsson, Eriksson and Nilsson5,Reference DiBartola, Barron and Smith7,Reference Bedard, Pelletier-Roy, Angers-Goulet, Leblanc and Pelet8 However, the difference in door openings between the preincision period and the postincision period has not been clearly defined. This factor is significant; previous studies have shown an increase in airborne contamination during the preincision period compared to the postincision period. Reference Perez, Holloway and Ehrenfeld3 Therefore, we sought to understand the reasons for door openings in the preincision and postincision periods to provide insight on how to best develop interventions for these 2 periods.

Methods

This study was cross-sectional and observational in design. Data were recorded at 3 large academic institutions between June 2019 and August 2020. Total hip and knee arthroplasty procedures were included. Revision procedures met exclusion criteria. Observations were made by 4 observers who all underwent identical training and used a standardized data collection form. The number of door openings was recorded as well as the reason for the door openings and the period in which the door was opened. Additionally, distractions associated with door openings were recorded and rated according to severity using a scale adopted from Healey et al. Reference Healey, Sevdalis and Vincent9

The preincision period was defined as the time between the opening of the sterile instrument tray to the first incision. The postincision period was defined as the time between the first incision and the application of the bandage. This study met the classification for “not human subject research” by our institutional review board. Data were analyzed using the Wilcoxon 2-sample median test.

Results

In this study, we observed 25 preincision sessions and 26 postincision sessions. Among them, 11 were total knee arthroplasties and 15 were total hip arthroplasties. The preincision period was a median of 56 minutes (IQR, 49–63). The median duration of surgery (postincision period) was 81 minutes (IQR, 67–91). Overall, we recorded 0.56 (IQR, 0.40–0.70) door openings per minute in the preincision period and 0.34 (IQR, 0.26–0.45) door openings per minute in the postincision period. We detected a significant difference between these 2 periods (P = .0036). The results were uniform across all 3 sites.

The following reasons were given for door openings in the preincision period, including the median number per case: 8 (25%) nurses obtaining supplies; 7 (20%) surgical team (ie attending physicians, residents, and medical students) entering and leaving the OR to check on the progress of the surgical preparation; and 7 (19%) other (eg, medication deliveries and nursing students entering and leaving) (Table 1). The following reasons were given for door openings in the postincision period, including the median number per case: 6 (18%) nurses obtaining supplies, 6 (18%) vendor getting supplies; 8 (17%) other (eg, radiology techs entering and leaving the operating room for radiograph-dependent cases or case-related questions) (Table 1).

Table 1. Reasons for Preincision and Postincision Door Openings

Furthermore, 36% of door openings with a subsequent question or discussion regarding surgical equipment were rated as severe distractions (7–9 on the 9-point distraction severity scale adopted from Healey et al Reference Healey, Sevdalis and Vincent9 ). Also, 70% of door opening distractions associated with case irrelevant talk were rated as a mild distractions (1–3 on the 9-point scale). In addition, 97% of door openings that did not result in a subsequent conversation were rated as mild distractions (1–3 on the 9-point scale).

Discussion

Our results are similar, although somewhat lower than previously reported door openings, such as Bedard et al, Reference Bedard, Pelletier-Roy, Angers-Goulet, Leblanc and Pelet8 who reported a rate of 0.84 door openings per minute in the preincision period and a rate of 0.54 door openings per minute in the postincision period. Based on our findings, it is unlikely that the surgical team is significantly distracted by the high rates of door openings. However, 36% of door openings associated with a question or conversation regarding surgical equipment were rated as a severe distractions and may contribute to surgical error and increased risk of SSI.

Although the literature on the effect of door openings during the postincision period is grwoing, little is known about the impact of door openings during the preincision period. Reference Lynch, Englesbe and Sturm1,Reference Bedard, Pelletier-Roy, Angers-Goulet, Leblanc and Pelet8 Given the previously reported significant increase in airborne contamination during the preincision period Reference Perez, Holloway and Ehrenfeld3 and the high rate of preincision door openings, it is reasonable to hypothesize that door openings Reference Perez, Holloway and Ehrenfeld3,Reference Andersson, Bergh, Karlsson, Eriksson and Nilsson5,Reference Birgand, Azevedo and Rukly10 may affect the sterility of the instrument tray. We found a significant difference in the reasons for door opening between the preincision and postincision periods, which signifies that their roles in the increased rates of SSI are likely distinct and that they should be investigated separately.

Nurse and vendor supplies constituted a considerable number of preincision door openings (25% and 5%, respectively) and postincision door openings (18% and 18%, respectively). A promising intervention to address these door openings would be the implementation of a checklist to ensure the presence of all necessary supplies prior to the preincision period. Further research is needed to understand the effect of door openings in the preincision and postincision period as well as to discover an effective and sustainable door-opening intervention.

Financial support

D.N.D. received grant support from The Infectious Diseases Society of America Foundation through the Grants for Emerging Researcher/Clinician Mentorship Program.

Conflicts of interest

All authors report no conflicts of interest relevant to this article.

References

Lynch, RJ, Englesbe, MJ, Sturm, L, et al. Measurement of foot traffic in the operating room: implications for infection control. Am J Med Qual 2009;24:4552.CrossRefGoogle ScholarPubMed
Pokrywka, M, Byers, K. Traffic in the operating room: a review of factors influencing air flow and surgical wound contamination. Infect Disord Drug Targets 2013;13:156161.CrossRefGoogle ScholarPubMed
Perez, P, Holloway, J, Ehrenfeld, L, et al. Door openings in the operating room are associated with increased environmental contamination. Am J Infect Control 2018;46:954956.CrossRefGoogle ScholarPubMed
Mears, SC, Blanding, R, Belkoff, SM. Door opening affects operating room pressure during joint arthroplasty. Orthopedics 2015;38:e991e994.CrossRefGoogle ScholarPubMed
Andersson, AE, Bergh, I, Karlsson, J, Eriksson, BI, Nilsson, K. Traffic flow in the operating room: an explorative and descriptive study on air quality during orthopedic trauma implant surgery. Am J Infect Control 2012;40:750755.CrossRefGoogle Scholar
Roth, JA, Juchler, F, Dangel, M, Eckstein, FS, Battegay, M, Widmer, AF. Frequent door openings during cardiac surgery are associated with increased risk for surgical site infection: a prospective observational study. Clin Infect Dis 2019;69:290294.CrossRefGoogle ScholarPubMed
DiBartola, AC, Barron, C, Smith, S, et al. Decreasing room traffic in orthopedic surgery: a quality improvement initiative. Am J Med Qual 2019;34:561568.CrossRefGoogle ScholarPubMed
Bedard, M, Pelletier-Roy, R, Angers-Goulet, M, Leblanc, PA, Pelet, S. Traffic in the operating room during joint replacement is a multidisciplinary problem. Can J Surg 2015;58:232236.CrossRefGoogle ScholarPubMed
Healey, AN, Sevdalis, N, Vincent, CA. Measuring intraoperative interference from distraction and interruption observed in the operating theatre. Ergonomics 2006;49:589604.CrossRefGoogle Scholar
Birgand, G, Azevedo, C, Rukly, S, et al. Motion-capture system to assess intraoperative staff movements and door openings: Impact on surrogates of the infectious risk in surgery. Infect Control Hosp Epidemiol 2019;40:566573.CrossRefGoogle ScholarPubMed
Figure 0

Table 1. Reasons for Preincision and Postincision Door Openings