Efficacy of fluorescent antibody methods for detection of Pasteurella pestis in carcasses of albino laboratory mice stored for various periods

Published online by Cambridge University Press:  15 May 2009

Bruce W. Hudson
Affiliation:
From the San Francisco Field Station, Technology Branch Communicable Disease Center, Public Health Service, U.S. Department of Health, Education, and Welfare, San Francisco 18, California
Stuart F. Quan
Affiliation:
From the San Francisco Field Station, Technology Branch Communicable Disease Center, Public Health Service, U.S. Department of Health, Education, and Welfare, San Francisco 18, California
Leo Kartman
Affiliation:
From the San Francisco Field Station, Technology Branch Communicable Disease Center, Public Health Service, U.S. Department of Health, Education, and Welfare, San Francisco 18, California
Rights & Permissions [Opens in a new window]

Extract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Fluorescent antibody techniques were used for detection of plague antigens in infected mouse carcasses stored at 4°–5° C., 20°–25° C. (room temperature) and 370° C. for periods as long as 340 days in certain cases. Tissues of two guinea-pigs infected with Pasteurella pestis were examined after 7 years storage at room temperature. The efficacy of the fluorescent antibody test was compared with blood agar plate culture and animal inoculation during periods in which viable plague bacilli were presumed to be present, and compared with Larson's modified Ascoli test for the presence of soluble plague antigens during periods in which plague bacteria were presumed to be non-viable.

Fluorescent antibody tests were superior to animal inoculation or cultural methods in detection of P. pestis antigens in mouse carcasses stored for 4 days or longer at 37° C., for 8 days or longer at 20°–25° C. (room temperature), and for 34 days or longer at 4°–5° C. Upon examination of specimens presumed to lack viable plague organisms the fluorescent antibody test and precipitin tests were approximately equal in efficiency for detection of plague antigens in carcasses stored for 16–82 days at 37° C. and for 16–82 days at 20°–25° C. Ten of 21 mice stored for longer periods (140 and 340 days) at 4°–5° C. were negative by precipitin tests, whereas 19 of the same 21 rodents were positive by fluorescent antibody tests. In addition, after 7 years storage at room temperature tissues of two plague-infected guinea-pigs were negative by Larson's modified Ascoli test but positive by the fluorescent antibody test.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1962

References

Baltazard, M., Davis, D. H. S., Devignat, R., Girard, G., Gohar, M. A., Kartman, L., Meyer, K. F., Parker, M. T., Pollitzer, R., Prince, F. M., Quan, S. F. & Wagle, P. (1956). Recommended laboratory methods for the diagnosis of plague. Bull. Wld. Hlth. Org. 14, 457.Google ScholarPubMed
Cavanaugh, P. C. & Quan, S. F. (1953). Rapid identification of Pasteurella peslis. J. clin. Path. 23, 619.CrossRefGoogle Scholar
Chen, T. H., Quan, S. F. & Meyer, K. F. (1952). Studies on immunization against plague. II. The complement-fixation test. J. Immunol. 68, 147.CrossRefGoogle ScholarPubMed
Chen, T. H. & Meyer, K. F. (1954). Studies on inummization against plague. VII. A hemagglutination test with the protein fraction of Pasteurella pestis: A serologic comparison of virulent and avirulent strains with observations on the structure of the bacterial cells and its relationship to infection and immunity. J. Immunol. 72, 282.CrossRefGoogle ScholarPubMed
Cherry, W. B., Goldman, M., Carski, T. R. & Moody, M. D. (1960). Fluorescent antibody techniques in the diagnosis of communicable diseases. Public Health Service Publication No. 729, U.S. Govt. Printing Office, Washington, D.C.Google Scholar
Curtain, C. C. (1961). The chromatographic purification of fluorescein antibody. J. Histochem. Cytochem. 9, 484.Google Scholar
Goldman, M. (1961). Immunochemical staining with fluorescent antibody. In International Review of Tropical Medicine. Vol. 1, p. 215. New York: Academic Press.Google Scholar
Hudson, B. W. (1961). Column adsorption of fluorescein-isothiocyanate-labelled antibodies. Bull. Wld. Hlth. Org. 24, 291.Google Scholar
Kartman, L. (1960). The role of rabbits in sylvatic plague epidemiology, with special attention to human cases in New Mexico and use of the fluorescent antibody technique for detection of Pasteurella pestis in field specimens. Zoonoses Res. 1, 1.Google Scholar
Larson, C. L., Philip, C. B., Cicht, W. C. & Hughes, L. E. (1951). Precipitin reactions with soluble antigens from suspensions of Pasteurella pestis or from tissues of animals dead of plague. J. Immunol. 67, 289.Google Scholar
Moody, M. D. & Winter, C. C. (1959). Rapid identification of Pasteurella pestis with fluorescent antibody. III. Staining Pasteurella pestis in tissue impression smears. J. infect. Dis. 104, 288.Google Scholar
Zwann, J. (1961). Rapid separation of fluorescent antisera and unconjugated dye. Acta Histoch. 11, 306.Google Scholar