Hostname: page-component-848d4c4894-ndmmz Total loading time: 0 Render date: 2024-06-02T06:09:46.440Z Has data issue: false hasContentIssue false

High-fidelity Human Patient Simulators Compared with Human Actors in an Unannounced Mass-Casualty Exercise

Published online by Cambridge University Press:  20 March 2014

Christian M. Schulz*
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Matthias Skrzypczak
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Stefan Raith
Affiliation:
Clinic for Plastic Surgery and Hand Surgery, Klinikum rechts der Isar, Technische Universität München, München, Germany
Dominik Hinzmann
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Veronika Krautheim
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Fabian Heuser
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Valentin Mayer
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Christoph Kreuzer
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Meike Himsl
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Michael Holl
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Christina Lipp
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Eberhard F. Kochs
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
Klaus J. Wagner
Affiliation:
Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany
*
Correspondence: Christian Schulz, MD Klinik für Anaesthesiologie Klinikum rechts der Isar Technische Universität München Ismaninger Str. 22 München 81675 Germany E-mail c.m.schulz@lrz.tum.de

Abstract

High-fidelity simulators (HFSs) have been shown to prompt critical actions at a level equal to that of trained human actors (HAs) and increase perceived realism in intrahospital mass-casualty incident (MCI) exercises. For unannounced prehospital MCI exercises, however, no data are available about the feasibility of incorporating HFSs. This case report describes the integration of HFSs in such an unannounced prehospital MCI drill with HAs and provides data about the differences concerning triage, treatment, and transport of HFSs and HAs with identical injury patterns. For this purpose, 75 actors and four high-fidelity simulators were subdivided into nine groups defined by a specific injury pattern. Four HFSs and six HAs comprised a group suffering from traumatic brain injury and blunt abdominal trauma. Triage results, times for transport, and number of diagnostic and therapeutic tasks were recorded. Means were compared by t test or one-way ANOVA.

Triage times and results did not differ between actors and simulators. The number of diagnostic (1.25, SD = 0.5 in simulators vs 3.5, SD = 1.05 in HAs; P = .010) and therapeutic tasks (2.0, SD = 1.6 in simulators vs 4.8, SD = 0.4 in HAs; P = .019) were significantly lower in simulators. Due to difficulties in treating and evacuating the casualties from the site of the accident in a timely manner, all simulators died. Possible causal factors and strategies are discussed, with the aim of increasing the utility of simulators in emergency medicine training.

SchulzCM, SkrzypczakM, RaithS, HinzmannD, KrautheimV, HeuserF, MayerV, KreuzerC, HimslM, HollM, LippC, KochsEF, WagnerKJ. High-fidelity Human Patient Simulators Compared with Human Actors in an Unannounced Mass-Casualty Exercise. Prehosp Disaster Med. 2014;29(2):1-7.

Type
Case Report
Copyright
Copyright © World Association for Disaster and Emergency Medicine 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

*

These authors contributed equally to this work.

References

1. Delooz, H, Debacker, M, Moens, G, Johannik, K. European survey on training objectives in disaster medicine. Eur J Emerg Med. 2007;14(1):25-31.Google Scholar
2. Wallace, D, Gillett, B, Wright, B, Stetz, J, Arquilla, B. Randomized controlled trial of high fidelity patient simulators compared to actor patients in a pandemic influenza drill scenario. Resuscitation. 2010;81(7):872-876.Google Scholar
3. Gillett, B, Peckler, B, Sinert, R, et al. Simulation in a disaster drill: comparison of high-fidelity simulators versus trawalined actors. Academic Emergency Medicine. 2008;15(11):1144-1151.Google Scholar
4. Ten, E. Simulation in emergency medicine training. Pediatr Emerg Care. 2011;27(4):333-341.Google Scholar
5. Vozenilek, J, Huff, J, Reznek, M, Gordon, JA. See one, do one, teach one: advanced technology in medical education. Acad Emerg Med. 2004;11(11):1149-1154.CrossRefGoogle ScholarPubMed
6. Fritz, PZ, Gray, T, Flanagan, B. Review of mannequin-based high-fidelity simulation in emergency medicine. Emerg Med Australas. 2008;20(1):1-9.Google Scholar
7. McFetrich, J. A structured literature review on the use of high fidelity patient simulators for teaching in emergency medicine. Emerg Med J. 2006;23(7):509-511.Google Scholar
8. Perkins, GD. Simulation in resuscitation training. Resuscitation. 2007;73(2):202-211.Google Scholar
9. Schulz, C, Zanner, R, Krautheim, V, Kochs, EF, Schneider, G. Etablierung eines Simulationskurses Notfallmedizin für angehende Notärzte. Notfall Rettungsmed. 2011;14(8):673-677.Google Scholar
10. Mayer, V, Schulz, CM, Kreuzer, M, Wagner, K, Schneider, G, Kochs, EF. Cardiopulmonary resuscitation performance during simulator-based trainings – a comparative retrospective analysis of adherence to 2005 and 2010 guidelines. Minerva Anestesiol. 2013;79(3):264-273.Google ScholarPubMed
11. Schulz, CM, Mayer, V, Kreuzer, M, Kochs, EF, Schneider, G. A tool for immediate and automated assessment of resuscitation skills for a full-scale simulator. BMC Res Notes. 2011;4:550.Google Scholar
12. Sefrin, P, Weidringer, J, Weiss, W. Sichtungskategorien und deren Dokumentation. Dtsch Arztebl. 2003;100(31/32):A2058-A2058.Google Scholar