Micro X-Ray Fluorescence Analysis with Synchrotron Radiation

Published online by Cambridge University Press:  06 March 2019

Shinjiro Hayakawa
Affiliation:
Department of Industrial Chemistry, Faculty of Engineering, University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113, Japan
Atsuo Iida
Affiliation:
Photon Factory, National Laboratory for High Energy Physics, Tsukuba-shi, Ibaraki 305, Japan
Sadao Aoki
Affiliation:
Institute of Applied Physics, University of Tsukuba, Tsukuba-shi, Ibaraki 305, Japan
Yohichi Gohshi
Affiliation:
Department of Industrial Chemistry, Faculty of Engineering, University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113, Japan
Get access

Abstract

A synchrotron radiation X-ray micro analyzer(SRXMA) was developed at Photon Factory in Japan. The present SRXMA combines a double crystal monochromator and mirror optics and either a white or a monochromatic microbeam can be used. Micro X-ray fluorescence analysis was carried out, and a minimum detection limit of 1 ppm for Mn was obtained for 100 sec measurement with the white beam. With monochromatic beam excitation, micro X-ray spectroscopies are now feasible.

The obtained beam size was 1.6 μ;m - 34 μm* The beam was blurred in one direction by the scattered X-rays caused by the surface irregularities of the focusing mirror. Improvements in the mirror quality will ensure a beam spot of just a few microns with sufficient intensity.

Type
IV. Techniques and XRF Instrumentation
Copyright
Copyright © International Centre for Diffraction Data 1988

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Gohshi, Y., Aoki, S., Iida, A., Hayakawa, S., Tamaji, H. and Sakurai, K., A Scanning X-ray Microprobe with Synchrotron Radiation, Jpn. J. Appl. Phys. 26: L1260 (1987).Google Scholar
2. Thompson, A.C., Underwood, J.H., Wu, Y., Giauque, R.D., Jones, K.W. and Rivers, M.L., Element Measurements with An X-ray Microprobe of Biological and Geological Samples with Femtogram Sensitivity, Nucl. Instr. and Methods A266: 318 (1988).Google Scholar
3. Iida, A. and Gohshi, Y., Energy Dispersive X-ray Fluorescence Analysis Using Synchrotron Radiation, in: “Advances In X-ray Analysis”, Barrettet, Charles S. al. , ed. Plenum Press, NY, Vol. 29, (1936).Google Scholar
4. Aoki, S., Gohshi, Y. and Iida, A., A10 keV X-ray Microprobe with Grazing Incidence Mirrors, in: “X-ray Microscopy”, Cheng, P.C. and Jan, G.J. ed. Springer-Verlag Berlin Heidelberg (1987).Google Scholar
5. Gohshi, Y., Aoki, S., Iida, A., Hayakawa, S., Yamaji, H. and Sakurai, K., A Scanning X-ray Microprobe with Synchrotron Radiation, in: ‘Advances In X-ray Analysis”, Predecki, P.K. et al. , ed. Plenum Press, NY, Vol. 31, (1988).Google Scholar
6. Sakurai, K., Iida, A. and Gohshi, Y., Chemical State Analysis by X-ray Fluorescence Using Shifts of Iron K Absorption Edge, Anal. Sci. 4:37(1988).Google Scholar
7. Sakurai, K., Iida, A., Takahashi, M. and Gohshi, Y., Chemical State Mapping by X-Ray Fluorescence Using Absorption Edge Shifts, Jpn. J. Appl. Phys. in press.Google Scholar