Skip to main content
×
Home
    • Aa
    • Aa
  • Get access
    Check if you have access via personal or institutional login
  • Cited by 25
  • Cited by
    This article has been cited by the following publications. This list is generated based on data provided by CrossRef.

    Hans, Michael Mathews, Salima Mücklich, Frank and Solioz, Marc 2016. Physicochemical properties of copper important for its antibacterial activity and development of a unified model. Biointerphases, Vol. 11, Issue. 1, p. 018902.


    Muller, M.P. MacDougall, C. and Lim, M. 2016. Antimicrobial surfaces to prevent healthcare-associated infections: a systematic review. Journal of Hospital Infection, Vol. 92, Issue. 1, p. 7.


    Schwarzkopf, A. Lechner, S. and Rösch, K. 2016. Antiseptisch beschichtete Stühle im Krankenhaus – Eine Feldstudie. Krankenhaus-Hygiene + Infektionsverhütung, Vol. 38, Issue. 2, p. 74.


    Vincent, Marin Hartemann, Philippe and Engels-Deutsch, Marc 2016. Antimicrobial applications of copper. International Journal of Hygiene and Environmental Health,


    Schmidt, Michael 2015. Practical Handbook of Microbiology, Third Edition.


    Hans, Michael Támara, Juan Carlos Mathews, Salima Bax, Benjamin Hegetschweiler, Andreas Kautenburger, Ralf Solioz, Marc and Mücklich, Frank 2014. Laser cladding of stainless steel with a copper–silver alloy to generate surfaces of high antimicrobial activity. Applied Surface Science, Vol. 320, p. 195.


    Humphreys, H. 2014. Self-disinfecting and Microbiocide-Impregnated Surfaces and Fabrics: What Potential in Interrupting the Spread of Healthcare-Associated Infection?. Clinical Infectious Diseases, Vol. 58, Issue. 6, p. 848.


    Loveday, H.P. Wilson, J.A. Pratt, R.J. Golsorkhi, M. Tingle, A. Bak, A. Browne, J. Prieto, J. and Wilcox, M. 2014. epic3: National Evidence-Based Guidelines for Preventing Healthcare-Associated Infections in NHS Hospitals in England. Journal of Hospital Infection, Vol. 86, p. S1.


    Maki, Dennis G. 2014. Stethoscopes and Health Care–Associated Infection. Mayo Clinic Proceedings, Vol. 89, Issue. 3, p. 277.


    Monk, Alastair B Kanmukhla, Vikram Trinder, Ken and Borkow, Gadi 2014. Potent bactericidal efficacy of copper oxide impregnated non-porous solid surfaces. BMC Microbiology, Vol. 14, Issue. 1, p. 57.


    Noimark, Sacha Allan, Elaine and Parkin, Ivan P. 2014. Light-activated antimicrobial surfaces with enhanced efficacy induced by a dark-activated mechanism. Chemical Science, Vol. 5, Issue. 6, p. 2216.


    Noimark, Sacha Page, Kristopher Bear, Joseph C. Sotelo-Vazquez, Carlos Quesada-Cabrera, Raul Lu, Yao Allan, Elaine Darr, Jawwad A. and Parkin, Ivan P. 2014. Functionalised gold and titania nanoparticles and surfaces for use as antimicrobial coatings. Faraday Discuss.,


    Park, Geun Woo Cho, Min Cates, Ezra L. Lee, David Oh, Byung-Taek Vinjé, Jan and Kim, Jae-Hong 2014. Fluorinated TiO2 as an ambient light-activated virucidal surface coating material for the control of human norovirus. Journal of Photochemistry and Photobiology B: Biology, Vol. 140, p. 315.


    Schmidt, M.G. John, J.F. and Johnson Va, Ralph H. 2014. Decontamination in Hospitals and Healthcare.


    Tamimi, Akrum H. Carlino, Sheri and Gerba, Charles P. 2014. Long-term efficacy of a self-disinfecting coating in an intensive care unit. American Journal of Infection Control, Vol. 42, Issue. 11, p. 1178.


    Yezli, Saber Barbut, Frédéric and Otter, Jonathan A. 2014. Surface Contamination in Operating Rooms: A Risk for Transmission of Pathogens?. Surgical Infections, Vol. 15, Issue. 6, p. 694.


    Hans, Michael Erbe, Andreas Mathews, Salima Chen, Ying Solioz, Marc and Mücklich, Frank 2013. Role of Copper Oxides in Contact Killing of Bacteria. Langmuir, Vol. 29, Issue. 52, p. 16160.


    Salgado, Cassandra D. Sepkowitz, Kent A. John, Joseph F. Cantey, J. Robert Attaway, Hubert H. Freeman, Katherine D. Sharpe, Peter A. Michels, Harold T. and Schmidt, Michael G. 2013. Copper Surfaces Reduce the Rate of Healthcare-Acquired Infections in the Intensive Care Unit. Infection Control & Hospital Epidemiology, Vol. 34, Issue. 05, p. 479.


    Schmidt, Michael G. Attaway, Hubert H. Fairey, Sarah E. Steed, Lisa L. Michels, Harold T. and Salgado, Cassandra D. 2013. Copper Continuously Limits the Concentration of Bacteria Resident on Bed Rails within the Intensive Care Unit. Infection Control & Hospital Epidemiology, Vol. 34, Issue. 05, p. 530.


    Weber, David J. and Rutala, William A. 2013. Self-disinfecting surfaces: Review of current methodologies and future prospects. American Journal of Infection Control, Vol. 41, Issue. 5, p. S31.


    ×
  • Infection Control & Hospital Epidemiology, Volume 33, Issue 1
  • January 2012, pp. 3-9

The Antimicrobial Efficacy of Copper Alloy Furnishing in the Clinical Environment: A Crossover Study

  • T. J. Karpanen (a1), A. L. Casey (a1), P. A. Lambert (a2), B. D. Cookson (a3), P. Nightingale (a4), L. Miruszenko (a5) and T. S. J. Elliott (a5)
  • DOI: http://dx.doi.org/10.1086/663644
  • Published online: 02 January 2015
Abstract
Objective.

To determine whether copper incorporated into hospital ward furnishings and equipment can reduce their surface microbial load.

Design.

A crossover study.

Setting.

Acute care medical ward with 19 beds at a large university hospital.

Methods.

Fourteen types of frequent-touch items made of copper alloy were installed in various locations on an acute care medical ward. These included door handles and push plates, toilet seats and flush handles, grab rails, light switches and pull cord toggles, sockets, overbed tables, dressing trolleys, commodes, taps, and sink fittings. Their surfaces and those of equivalent standard items on the same ward were sampled once weekly for 24 weeks. The copper and standard items were switched over after 12 weeks of sampling to reduce bias in usage patterns. The total aerobic microbial counts and the presence of indicator microorganisms were determined.

Results.

Eight of the 14 copper item types had microbial counts on their surfaces that were significantly lower than counts on standard materials. The other 6 copper item types had reduced microbial numbers on their surfaces, compared with microbial counts on standard items, but the reduction did not reach statistical significance. Indicator microorganisms were recovered from both types of surfaces; however, significantly fewer copper surfaces were contaminated with vancomycin-resistant enterococci, methicillin-susceptible Staphylococcus aureus, and coliforms, compared with standard surfaces.

Conclusions.

Copper alloys (greater than or equal to 58% copper), when incorporated into various hospital furnishings and fittings, reduce the surface microorganisms. The use of copper in combination with optimal infection-prevention strategies may therefore further reduce the risk that patients will acquire infection in healthcare environments.

Infect Control Hosp Epidemiol 2012;33(1):3-9

Copyright
Corresponding author
Corporate Division, Queen Elizabeth Hospital, University Hospitals Birmingham National Health Service Foundation Trust, Edgbaston, Birmingham B15 2TH, United Kingdom (tom.elliott@uhb.nhs.uk)
Linked references
Hide All

This list contains references from the content that can be linked to their source. For a full set of references and notes please see the PDF or HTML where available.

1.B Allegranzi , J Storr , G Dziekan , A Leotsakos , L Donaldson , D Pittet . The first global patient safety challenge “clean care is safer care”: from launch to current progress and achievements. J Hosp Infect 2007;65(suppl 2):115123.

3.RJ Pratt , CM Pellowe , JA Wilson , et al. Epic2: national evidence-based guidelines for preventing healthcare-associated infections in NHS hospitals in England. J Hosp Infect 2007;65(suppl 1):S1S64.

4.JM Boyce . Environmental contamination makes an important contribution to hospital infection. J Hosp Infect 2007;65(suppl 2):5054.

5.PC Carling , JM Bartley . Evaluating hygienic cleaning in health care settings: what you do not know can harm your patients. Am J Infect Control 2010;38:S41S50.

6.SJ Dancer . The role of environmental cleaning in the control of hospital-acquired infection. J Hosp Infect 2009;73:378385.

7.DJ Gould , D Moralejo , N Drey , JH Chudleigh . Interventions to improve hand hygiene compliance in patient care. Cochrane Database Syst Rev 2010:CD005186.

8.S Scheithauer , A Oberrohrmann , H Haefner , et al. Compliance with hand hygiene in patients with methicillin-resistant Staphylococcus aureus and extended-spectrum β-lactamase-producing enterobacteria. J Hosp Infect 2010;76:320323.

9.KJ Hardy , S Gossain , N Henderson , et al. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. J Hosp Infect 2007;66:360368.

10.L Taylor , P Phillips , R Hastings . Reduction of bacterial contamination in a healthcare environment by silver antimicrobial technology. J Infect Prevent 2009;10:612.

12.G Grass , C Rensing , M Solioz . Metallic copper as an antimicrobial surface. Appl Environ Microbiol 2011;77(5):15411547.

13.CE Santo , EW Lam , CG Elowsky , et al. Bacterial killing by dry metallic copper surfaces. Appl Environ Microbiol 2011;77:794802.

14.L Weaver , JO Noyce , HT Michels , CW Keevil . Potential action of copper surfaces on methicillin-resistant Staphylococcus aureus. J Appl Microbiol 2010;109:22002205.

15.CE Santo , PV Morais , G Grass . Isolation and characterization of bacteria resistant to metallic copper surfaces. Appl Environ Microbiol 2010;76:13411348.

16.EC Santo , N Taudte , DH Nies , G Grass . Contribution of copper ion resistance to survival of Escherichia coli on metallic copper surfaces. Appl Environ Microbiol 2008;74:977986.

18.AL Casey , D Adams , TJ Karpanen , et al. Role of copper in reducing hospital environment contamination. J Hosp Infect 2010;74:7277.

19.F Marais , S Mehtar , L Chalkley . Antimicrobial efficacy of copper touch surfaces in reducing environmental bioburden in a South African community healthcare facility. J Hosp Infect 2010;74:8082.

20.A Mikolay , S Huggett , L Tikana , G Grass , J Braun , DH Nies . Survival of bacteria on metallic copper surfaces in a hospital trial. Appl Microbiol Biotechnol 2010;87:18751879.

21.LJ Wheeldon , T Worthington , PA Lambert , AC Hilton , CJ Lowden , TS Elliott . Antimicrobial efficacy of copper surfaces against spores and vegetative cells of Clostridium difficile, the germination theory. J Antimicrob Chemother 2008;62:522525.

22.PC Carling , S Von Beheren , P Kim , C Woods . Intensive care unit environmental cleaning: an evaluation in sixteen hospitals using a novel assessment tool. J Hosp Infect 2008;68:3944.

24.C La Forgia , J Franke , DM Hacek , RB Thomson Jr, A Robicsek , LR Peterson . Management of a multidrug-resistant Acinetobacter baumannii outbreak in an intensive care unit using novel environmental disinfection: a 38-month report. Am J Infect Control 2010;38:259263.

Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Infection Control & Hospital Epidemiology
  • ISSN: 0899-823X
  • EISSN: 1559-6834
  • URL: /core/journals/infection-control-and-hospital-epidemiology
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×