Improved Three-Dimensional (3D) Resolution of Electron Tomograms Using Robust Mathematical Data-Processing Techniques

  • Toby Sanders (a1) and Ilke Arslan (a2)
Abstract

Electron tomography has become an essential tool for three-dimensional (3D) characterization of nanomaterials. In recent years, advances have been made in specimen preparation and mounting, acquisition geometries, and reconstruction algorithms. All of these components work together to optimize the resolution and clarity of an electron tomogram. However, one important component of the data-processing has received less attention: the 2D tilt series alignment. This is challenging for a number of reasons, namely because the nature of the data sets and the need to be coherently aligned over the full range of angles. An inaccurate alignment may be difficult to identify, yet can significantly limit the final 3D resolution. In this work, we present an improved center-of-mass alignment model that allows us to overcome discrepancies from unwanted objects that enter the imaging area throughout the tilt series. In particular, we develop an approach to overcome changes in the total mass upon rotation of the imaging area. We apply our approach to accurately recover small Pt nanoparticles embedded in a zeolite that may otherwise go undetected both in the 2D microscopy images and the 3D reconstruction. In addition to this, we highlight the particular effectiveness of the compressed sensing methods with this data set.

Copyright
Corresponding author
* Corresponding author. toby.sanders@asu.edu
References
Hide All
Batenburg, K.J., Bals, S., Sijbers, J., Kbel, C., Midgley, P.A., Hernandez, J.C., Kaiser, U., Encina, E.R., Coronado, E.A. & Van Tendeloo, G. (2009). 3d imaging of nanomaterials by discrete tomography. Ultramicroscopy 109(6), 730740.
Binev, P., Dahmen, W., DeVore, R., Lamby, ., Savu, D. & Sharpley, R. (2012). Compressed sensing and electron microscopy. In Modeling Nanoscale Imaging in Electron Microscopy, pp. 73126. New York, NY: Springer.
Brandt, S., Heikkonen, J. & Engelhardt, P. (2001). Automatic alignment of transmission electron microscope tilt series without fiducial markers. J Struct Biol 136(3), 201213.
Chen, Z., Jin, X., Li, L. & Wang, G. (2013). A limited-angle CT reconstruction method based on anisotropic TV minimization. Phys Med Biol 58(7), 2119.
Frank, J. (2006). Introduction: Principles of electron tomography. In Electron Tomography: Methods for Three-Dimensional Visualization of Structures in the Cell, pp. 1–15. New York, NY: Springer New York.
Goris, B., Roelandts, T., Batenburg, K.J., Heidari Mezerji, H. & Bals, S. (2013). Advanced reconstruction algorithms for electron tomography: From comparison to combination. Frontiers of Electron Microscopy in Materials Science. Ultramicroscopy 127, 4047.
Hayashida, M. & Malac, M. (2016). Practical electron tomography guide: Recent progress and future opportunities. Micron 91, 4974.
Houben, L. & Bar Sadan, M. (2011). Refinement procedure for the image alignment in high-resolution electron tomography. Ultramicroscopy 111(9), 15121520.
Jones, S.D. & Härting, M. (2013). A new correlation based alignment technique for use in electron tomography. Ultramicroscopy 135, 5663.
Kremer, J.R., Mastronarde, D.N. & McIntosh, J.R. (1996). Computer visualization of three-dimensional image data using IMOD. J Struct Biol 116(1), 7176.
Leary, R., Saghi, Z., Midgley, P.A. & Holland, D.J. (2013). Compressed sensing electron tomography. Ultramicroscopy 131, 7091.
Lučić, V., Förster, F. & Baumeister, W. (2005). Structural studies by electron tomography: from cells to molecules. Annu Rev Biochem 74, 833865.
Masich, S., Östberg, T., Norlén, L., Shupliakov, O. & Daneholt, B. (2006). A procedure to deposit fiducial markers on vitreous cryo-sections for cellular tomography. J Struct Biol 156(3), 461468.
Sanders, T. (2017). Matlab imaging algorithms: Image reconstruction, restoration, and alignment, with a focus in tomography. Available at http://www.toby-sanders.com/software, https://doi.org/10.13140/RG.2.2.33492.60801 (retrieved January 2017).
Sanders, T., Gelb, A., Platte, R.B., Arslan, I. & Landskron, K. (2017). Recovering fine details from under-resolved electron tomography data using higher order total variation regularization. Ultramicroscopy 174, 97105.
Sanders, T., Prange, M., Akatay, C. & Binev, P. (2015). Physically motivated global alignment method for electron tomography. Adv Struct Chem Imaging 1(1), 111.
Saxton, W.O., Baumeister, W. & Hahn, M. (1984). Three-dimensional reconstruction of imperfect two-dimensional crystals. Ultramicroscopy 13(1–2), 5770.
Scott, M.C., Chien-Chun, C., Mecklenburg, M., Zhu, C., Xu, R., Ercius, P., Dahmen, U., Regan, B.C. & Miao, J. (2012). Electron tomography at 2.4-angstrom resolution. Nature 483(7390), 444447.
Sorzano, C.O.S., Messaoudi, C., Eibauer, M., Bilbao-Castro, J.R., Hegerl, R., Nickell, S., Marco, S. & Carazo, J.M. (2009). Marker-free image registration of electron tomography tilt-series. BMC Bioinformatics 10(1), 124.
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Microscopy and Microanalysis
  • ISSN: 1431-9276
  • EISSN: 1435-8115
  • URL: /core/journals/microscopy-and-microanalysis
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords

Type Description Title
UNKNOWN
Supplementary materials

Sanders and Arslan supplementary material
Sanders and Arslan supplementary material 1

 Unknown (41.4 MB)
41.4 MB

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed