Light Microscopy Image Collection: Confocal, Widefield and Deconvolution

Published online by Cambridge University Press:  02 July 2020

J. N. Turner
Affiliation:
Wadsworth Center, New York State Department of Health, Albany, NY, 12201 Rensselaer Polytechnic Institute, Troy, NY, 12180
D. H. Szarowski
Affiliation:
Wadsworth Center, New York State Department of Health, Albany, NY, 12201
B. Roysam
Affiliation:
Rensselaer Polytechnic Institute, Troy, NY, 12180 AutoQuant Imaging Inc., Troy, NY, 12180
T. J. Holmes
Affiliation:
Rensselaer Polytechnic Institute, Troy, NY, 12180 AutoQuant Imaging Inc., Troy, NY, 12180
Get access

Extract

Light microscopy instrumentation and biological applications continue to expand rapidly, and an important aspect of this expansion is three-dimensional (3-D) imaging and image analysis. For many biological specimens, optical sectioning, i.e. collecting images at a sequence of depths under controlled conditions, provides true 3-D data through the entire specimen. This is especially important for specimens whose thickness exceeds the depth-of-field of the microscope objective lens. This sequence of optical sections is the basis for 3-D image reconstruction providing information from all three specimen dimensions instead of just the traditional two in the image plane of the microscope. The analysis of images in 3-D provides insights into the structure and function of biological specimens that are not available through other means. However, 3-D microscopy also presents additional choices for image collection. The first of which is whether to use widefield or confocal microscopy and the second is whether to utilize digital deblurring or deconvolution methods.

Type
Tutorials
Copyright
Copyright © Microscopy Society of America 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Agard, D., Annu. Rev. Biophys. Bioeng. 13(1984)191.CrossRefGoogle Scholar

2. Pawley, J., Handbook of Biological Confocal Microscopy Plenum Press, New York (1995).CrossRefGoogle Scholar

3. Matsumoto, B., Cell Biological Applications of Confocal Microscopy, Methods in Cell Biology Vol. 38, Academic Press, New York (1993).Google Scholar

4. Holmes, T., et al., in Handbook of Biological Confocal Microscopy (ed. Pawley, J.) (1995)389.Google Scholar

5. Turner, J. N.et al., Int. J. Imaging Systems and Technology, (1997) In press.Google Scholar

6. Lin, W., et al., J. Computer Assisted Microsc. 6(1994)113.Google Scholar

7. Support: NIH R43-EY11174, R43-MH53691, R43-MH53692; NSF BES-9413037.Google Scholar