New Scanning Electron Microscope Sharpness Standard: NIST Reference Material 8091 (Rm 8091)

Published online by Cambridge University Press:  02 July 2020

M. T. Postek
Affiliation:
National Institute of Standards and Technology, Gaithersburg, MD, 20899-8121
A. E. Vladar
Affiliation:
National Institute of Standards and Technology, Gaithersburg, MD, 20899-8121
N.-F. Zhang
Affiliation:
National Institute of Standards and Technology, Gaithersburg, MD, 20899-8121
R. Larrabee
Affiliation:
National Institute of Standards and Technology, Gaithersburg, MD, 20899-8121
Get access

Abstract

All scanning electron microscopes, whether they are in laboratory or on the production line, slowly lose performance as the instrument is used. This loss of performance is due to a whole array of contributing factors including misalignments, contamination and increases in source diameter. Identifying a loss in “sharpness” easily recognizes this performance decrease. Reference Material 8091 (RM 8091) is intended primarily for use in routinely checking the sharpness performance of scanning electron microscopes (Fig. 1). RM 8091 is designed to be used in conjunction with the SPECTEL SEM Monitor Program, the NIST Kurtosis program,3 or the University of Tennessee SMART program. RM 8091 is supplied as a small, approximately 2 mm x 2 mm diced semiconductor chip. This sample is capable of being mounted directly on to a wafer, wafer piece or specimen stub for insertion into a laboratory scanning electron microscope or wafer inspection scanning electron microscope.

Type
Microscopy in the Real World: Semiconductors and Materials
Copyright
Copyright © Microscopy Society of America 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Postek, M. T. and Vladar, A. E., A. E., SCANNING 20 (1998): 19.CrossRefGoogle Scholar
2.Vladar, A. E. et al., SCANNING 20 (1998): 2434.CrossRefGoogle Scholar
3.Zhang, N. -F. et al., SCANNING 21 (1999):256262.Google ScholarPubMed
4.Joy, D. C., Scanning 22 (2000): 110111Google Scholar
5.Postek, M. T., M. T. and Vladar, A. E.Proceedings SPIE 2725 (1996): 504514.CrossRefGoogle Scholar
6. This work was supported in part by International SEMATECH and the NIST Office of Microelectronics Programs.Google Scholar