Quantitative Chemical Mapping with Low-Voltage EDS Spectrum Imaging and Multivariate Statistical Analysis (MSA)

Published online by Cambridge University Press:  02 July 2020

I.M. Anderson*
Affiliation:
Metals & Ceramics Division, Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN37831
Get access

Extract

One of the advantages of performing X-ray microanalysis at low (≤5 kV) operating voltages is that high spatial resolution (≤250 nm) chemical maps of the specimen can be acquired. Spectrum imaging, where a full spectrum is acquired for each pixel in a two-dimensional array, provides the most comprehensive method of characterization, as long as the sampling density (pixel size) is sufficiently smaller than the spatial resolution. Multivariate statistical analysis (MSA) methods are effective in reducing the large (typically ∼10 MByte) raw spectrum images to the modest (typically ∼100 kByte) data files that contain all of the statistically significant information of interest about the specimen. Preliminary analysis of a cross section of a computer chip from a major semiconductor company was previously performed using limited spectrum imaging capabilities available with the 4pi X-ray mapping module, which allowed for simultaneous acquisition of only 48 channels. MSA of images acquired with only a 960 eV portion of the spectrum containing the Al-K, Si-K and W-M lines showed that excellent contrast between the Si- and W-rich regions of the specimen could be achieved in spite of the strong overlap between Si-Kα and W-Mα (∼34 eV separation).

Type
Low Voltage (1-5 kv) X-ray Microanalysis
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Nockolds, C.E., Microbeam Analysis 3(1994)185; Proc. Microscopy & Microanalysis 1996, 476.Google Scholar

2. Boyes, E., Proc. 13th ICEM: Electron Microscopy 1994 1(1994)51.Google Scholar

3. Johnson, M.T.et al., Proc. Microscopy & Microanalysis 1996, 478.Google Scholar

4. Newbury, D.E., Proc. Microscopy & Microanalysis 1997, 881.Google Scholar

5. Anderson, I.M., Proc. Microscopy & Microanalysis 1998, 272.Google Scholar

6. Anderson, I.M., Proc. 14th ICEM: Electron Microscopy 1998 1(1998)357.Google Scholar

7. Anderson, I.M. and Bentley, J., Proc. Microscopy & Microanalysis 1997, 931.Google Scholar

8. Anderson, I.M. and Bentley, J., Mater. Res. Soc. Symp. Proc. 458(1997)81.CrossRefGoogle Scholar

9. Research at the Oak Ridge National Laboratory SHaRE User Facility was sponsored by the Division of Materials Sciences, U.S. Department of Energy, under contract DE-AC05-96OR22464 with Lockheed Martin Energy Research Corporation.Google Scholar