Hostname: page-component-848d4c4894-4rdrl Total loading time: 0 Render date: 2024-06-20T22:15:28.717Z Has data issue: false hasContentIssue false

Quantitative Immunocytochemistry of Proteins Using 2- Photon Microscopy and Digital Image Analysis.

Published online by Cambridge University Press:  02 July 2020

H. Wan
Affiliation:
Department of Pharmacology & Clinical Pharmacology, St George's Hospital Medical School, London, SW17 0RE, UK
C. Soeller
Affiliation:
Department of Pharmacology & Clinical Pharmacology, St George's Hospital Medical School, London, SW17 0RE, UK Department of Physiology, University of Auckland, Auckland 1, NZ.
D.R. Garrod
Affiliation:
School of Biological Sciences, University of Manchester, Manchester, Ml3 9PT, UK
C. Robinson
Affiliation:
Department of Pharmacology & Clinical Pharmacology, St George's Hospital Medical School, London, SW17 0RE, UK
M.B. Cannell
Affiliation:
Department of Pharmacology & Clinical Pharmacology, St George's Hospital Medical School, London, SW17 0RE, UK Department of Physiology, University of Auckland, Auckland 1, NZ.
Get access

Extract

The two photon microscope provides optical sectioning of fluorescent specimens with a resolution comparable to that obtained in confocal microscopy (see refs 2,3). However, the excited volume in 2-photon microscopy is limited to the focal volume (unlike conventional fluorescence microscopy where excitation occurs throughout the specimen). This means that photodamage is limited to the plane of section being examined. Thus, the light emitted from each point in the specimen depends on the amount of fluorochrome present without the problem of prior illumination (of other planes within the specimen) reducing the photon yield so a better signal to noise ratio can be obtained when examination of multiple image planes is needed. Since 2-photon excitation spectra are wide and chromatic aberration is eliminated (because the emitted light does not have to be focused on a pinhole), it is possible to excite several fluorochromes simultaneously and map their positions with high accuracy.

Type
New Developments in Multi-Photon Excitation Microscopy
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Denk, W. et al., Science, 248 (1990) 73.CrossRefGoogle Scholar
2.Pawley, J.B.. Handbook of biological confocal microscopy. 2nd ed. Plenum, N.Y. (1995)CrossRefGoogle Scholar
3.Soeller, C., and Cannell, M.B.. Pflugers Arch., 432 (1996) 555.CrossRefGoogle Scholar
4.Xu, C. and Webb, W.W.J. Opt. Soc. Am. B., 13 (1996) 481.CrossRefGoogle Scholar
5.Stevenson, B.R. et al., J. Cell Biol., 103 (1986) 755.CrossRefGoogle Scholar
6.Sakakibara, A. et al.,. J. Cell Biol., 137 (1997) 1393.CrossRefGoogle Scholar