Hostname: page-component-76fb5796d-dfsvx Total loading time: 0 Render date: 2024-04-28T19:03:09.319Z Has data issue: false hasContentIssue false

Ion Beam Deposition of Calcium Hydroxyapatite

Published online by Cambridge University Press:  26 February 2011

B. L. Barthell
Affiliation:
Los Alamos National Laboratory, Materials Science and Technology Division, Los Alamos, NM 87545
T. A. Archuleta
Affiliation:
Los Alamos National Laboratory, Materials Science and Technology Division, Los Alamos, NM 87545
Ram Kossowsky
Affiliation:
Penn State University, Applied Research Laboratory, State College, PA 16804
Get access

Abstract

Calcium hydroxyapatite has been sputtered on glass and Ti-6Al-4V substrates using a 1.5-kV argon ion beam. The films have been examined by x-ray diffraction analysis, energy dispersive spectroscopy, scanning electron microscopy, and adhesion testing. Results of this experimentation are presented.

Type
Research Article
Copyright
Copyright © Materials Research Society 1988

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Yettriuim, A. L. and Wright, K.W.J., J. Biomed. Eng. 2, 54 (1980).Google Scholar
2. Williams, D. F., Biocompatibility of Clinical Implant Materials (CRC Press, Boca Raton, 1981).Google Scholar
3. Venable, C. S. and Stuck, W. G., The Internal Fixation of Fractures (Springfield, New York, 1947).Google Scholar
4. Ghista, D. N., Biomechanics of Medical Devices (Dekker, New York, 1980).Google Scholar
5. Charnley, J., Follaci, F. M., and Hammond, B. T., J. Bone Joint Surg. 50B, 822 (1968).Google Scholar
6. Charnley, J., Acrylic Cement in Orthopedic Surgery (Williams and Wilkins, Baltimore, 1970).Google Scholar
7. Pilliar, R. M., in Materials Science and Implant Orthopedic Surgery, edited by Kossowsky, R. and Kossovsky, , NATO ASI Series E (Martinus Nijhoff, Dordrecht, 1986), p. 97.CrossRefGoogle Scholar
8. Hench, L. L. and Ethridge, E. C., Biomaterials, An Orthopedic Approach (Academic Press, New York, 1982).Google Scholar
9. Roy, D. M., Drafall, L. E., and Roy, R., in Refractory Materials, Volume 6–V, edited by Alper, A. M. (Academic Press, New York, 1978), p. 185.Google Scholar
10. Hulbert, S. F., in Use of Ceramics in Surgical Implants, edited by Hulbert, S. F. and Young, F. A. (Gordon and Breach, New York, 1971), p. 1.Google Scholar
11. Hulbert, S. F., Hench, L. L., Forbes, D., and Bowman, L. S., in Ceramics in Surgery, edited by Vincenzini, P. (Elsevier, Amsterdam, 1983), p. 3.Google Scholar
12. Berry, J. L., Geiger, J. M., Moran, J. M., Skraba, J. S., and Greenwald, A. S., J. Biomed. Mat. Res. 20, 65 (1986).Google Scholar
13. Morancho, R., Ghommidh, J., Constant, G., Moyen, B., Comtet, J. J., Santini, R., and Buttazzoni, B., in Ceramics in Surgery, edited by Vincenzini, P. (Elsevier, Amsterdam, 1983), p. 97.Google Scholar
14. Klein, C.P.A.T., Van der Lubbe, M.B.M., Driessen, A.A., de Groot, K., and van der Hoff, A., in Ceramics in Surgery, edited by Vincenzini, P. (Elsevier, Amsterdam, 1983), p. 105.Google Scholar