Hostname: page-component-76fb5796d-x4r87 Total loading time: 0 Render date: 2024-04-26T12:23:05.593Z Has data issue: false hasContentIssue false

Heterogeneous integration of Polymer Porous Photonic Bandgap Structure with Xerogel based Biochemical Sensors

Published online by Cambridge University Press:  21 March 2011

Huina Xu
Affiliation:
Department of Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY
Ke Liu
Affiliation:
Department of Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY
Ka Yi Yung
Affiliation:
Department of Chemistry, University at Buffalo, State University of New York, Buffalo, NY
Frank V. Bright
Affiliation:
Department of Chemistry, University at Buffalo, State University of New York, Buffalo, NY
Alexander N. Cartwright
Affiliation:
Department of Electrical Engineering, University at Buffalo, State University of New York, Buffalo, NY
Get access

Abstract

We report the heterogeneous integration of a multifunctional sensor based on polymer porous photonic bandgap (P3BG) structure and xerogel based luminescence sensor technology. The P3BG structure was fabricated using holographic interferometry. Initially, holographic interferometry of a photo-activated prepolymer syrup that included a volatile solvent as well as monomer, photoinitiator, and co-initiator was used to initiate photopolymerization. Subsequent UV curing resulted in well defined lamellae of the polymer separated by porous polymer regions that created a high quality photonic bandgap structure. The resulting P3BG structure was then integrated with the xerogel based luminescence element to produce a luminescence sensor with a selective narrow band reflector. The prototype xerogel based luminescence sensor element consisted of an O2 sensing material based on spin coated tetraethylorthosilane (TEOS) composite xerogel films containing tris (4,7-diphenyl-1,10-phenanthroline) ruthenium (II) ([Ru(dpp)3]2+) luminophore. We demonstrated enhancement of the signal-to-noise ratio (SNR) of this integrated multifunctional sensor while maintaining the same sensitivity to O2 sensing of the xerogel based element. The resulting advantages and enhanced SNR of this integrated sensor will provide a template for other luminescence based assays to support highly sensitive and cost-effective sensor systems for biomedical applications.

Type
Research Article
Copyright
Copyright © Materials Research Society 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Bunning, T. J., Natarajan, L. V., Tondiglia, V. P. and Sutherland, R. L., Annual Review of Materials Science 30 (1), 83115 (2000).Google Scholar
2. Hsiao, V. K. S., Kirkey, W. D., Chen, F., Cartwright, A. N., Prasad, P. N. and Bunning, T. J., Advanced Materials 17 (18), 22112214 (2005).10.1002/adma.200401888Google Scholar
3. Lakowicz, J. R., Principles of Luminescence Spectroscopy, 3rd ed. (Springer Science+Business Media, LLC., New York, 2006).Google Scholar
4. Vukusic, P., Sambles, J. R. and Lawrence, C. R., Nature 404 (6777), 457-457 (2000).Google Scholar
5. Holthoff, E. L. and Bright, F. V., Accounts of Chemical Research 40 (9), 756767 (2007).Google Scholar
6. Hsiao, V. K. S., Lin, T.-C., He, G. S., Cartwright, A. N., Prasad, P. N., Natarajan, L. V., Tondiglia, V. P. and Bunning, T. J., Applied Physics Letters 86 (13), 13111313 (2005).Google Scholar
7. Kim, S. J., Chodavarapu, V. P., Cartwright, A. N., Swihart, M. T. and Bunning, T. J., Sensors and Actuators B: Chemical 130 (2), 758764 (2008).Google Scholar
8. Tang, Y., Tao, Z., Bukowski, R. M., Tehan, E. C., Karri, S., Titus, A. H. and Bright, F. V., Analyst 131 (10), 11291136 (2006).Google Scholar