Abstract
Nitrogen-13 labeled ammonia ([13N]NH3) has been used for myocardial perfusion imaging with Positron Emission Tomography for decades. Recent increases to regulatory oversight have led to stricter adherence Good Manufacturing Practice (GMP) to produce this short half-life (9.97 min) radiopharmaceutical. This has increased production costs. Our cyclotron facility initially developed a
manual GMP production method, but it was prone to human error. With increased costs in mind, we developed and validation an Arduino-based device to purifying [13N]NH3 for clinical use. Construction, programming, and GMP validation results are discussed. The automated method was found to produce equivalent quality radiopharmaceutical but was more reproducible and robust.



![Author ORCID: We display the ORCID iD icon alongside authors names on our website to acknowledge that the ORCiD has been authenticated when entered by the user. To view the users ORCiD record click the icon. [opens in a new tab]](https://www.cambridge.org/engage/assets/public/coe/logo/orcid.png)