Skip to main content
×
Home
    • Aa
    • Aa

Increasing the injection volume by dilution improves the onset of motor blockade, but not sensory blockade of ropivacaine for brachial plexus block

  • H. Krenn (a1), E. Deusch (a1) (a2), B. Balogh (a3) (a4), H. Jellinek (a1), W. Oczenski (a1), E. Plainer-Zöchling (a1) and R. D. Fitzgerald (a1) (a5)
  • DOI: http://dx.doi.org/10.1017/S0265021503000048
  • Published online: 01 June 2005
Abstract

Summary

Background and objective: Ropivacaine used for axillary plexus block provides effective motor and sensory blockade. Varying clinical dosage recommendations exist. Increasing the dosage by increasing the concentration showed no improvement in onset. We compared the behaviour of a constant dose of ropivacaine 150 mg diluted in a 30, 40 or 60 mL injection volume for axillary (brachial) plexus block.

Methods: A prospective, randomized, observer-blinded study on patients undergoing elective hand surgery was conducted in a community hospital. Three groups of patients with a constant dose of ropivacaine 150 mg, diluted in 30, 40 or 60 mL NaCl 0.9%, for axillary plexus blockade were compared for onset times of motor and sensory block onset by assessing muscle strength, two-point discrimination and constant-touch sensation.

Results: Increasing the injection volume of ropivacaine 150 mg to 60 mL led to a faster onset of motor block, but not of sensory block, in axillary plexus block, compared with 30 or 40 mL volumes of injection.

Conclusions: The data show that the onset of motor, but not of sensory block, is accelerated by increasing the injection volume to 60 mL using ropivacaine 150 mg for axillary plexus block. This may be useful for a more rapid determination of whether the brachial plexus block is effective. However, when performing surgery in the area of the block, sensory block onset seems more important.

Copyright
Corresponding author
Correspondence to: Herbert Krenn, Department of Anaesthesia and Critical Care, City Hospital, Lainz, Wolkersbergenstrasse 1, A-1130 Vienna, Austria. E-mail: herbert.krenn@chello.at; Tel: +43 1 80110 2701; Fax: +43 1 80110 2696
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

European Journal of Anaesthesiology
  • ISSN: 0265-0215
  • EISSN: 1365-2346
  • URL: /core/journals/european-journal-of-anaesthesiology
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords: