Skip to main content Accessibility help
×
Home
Hostname: page-component-6c8bd87754-lkb8j Total loading time: 0.165 Render date: 2022-01-18T13:53:51.784Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": true, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true, "newUsageEvents": true }

Feasibility of Routinely Using Hydrogen Peroxide Vapor to Decontaminate Rooms in a Busy United States Hospital

Published online by Cambridge University Press:  02 January 2015

Jonathan A. Otter*
Affiliation:
BIOQUELL (UK), Andover, Hampshire, United Kingdom
Matthew Puchowicz
Affiliation:
BIOQUELL, Philadelphia, Pennsylvania
David Ryan
Affiliation:
BIOQUELL, Philadelphia, Pennsylvania
James A. G. Salkeld
Affiliation:
BIOQUELL, Philadelphia, Pennsylvania
Timothea A. Cooper
Affiliation:
Hospital of Saint Raphael, New Haven, Connecticut
Nancy L. Havill
Affiliation:
Hospital of Saint Raphael, New Haven, Connecticut
Kathy Tuozzo
Affiliation:
Hospital of Saint Raphael, New Haven, Connecticut
John M. Boyce
Affiliation:
Hospital of Saint Raphael, New Haven, Connecticut Yale University School of Medicine, New Haven, Connecticut
*
BIOQUELL (UK), 52 Royce Close, West Portway, Andover, Hampshire, SPIO 3TS, United Kingdom(jon.otter@bioquell.com)

Abstract

During a 22-month period at a 500-bed teaching hospital, 1,565 rooms that had housed patients infected with multidrug-resistant pathogens were decontaminated using hydrogen peroxide vapor. Hydrogen peroxide vapor decontamination required a mean time of 2 hours and 20 minutes, compared with 32 minutes for conventional cleaning. Despite the greater time required for decontamination, hydrogen peroxide vapor decontamination of selected patient rooms is feasible in a busy hospital with a mean occupancy rate of 94%.

Type
Concise Communications
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2009

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Mayfield, IL, Leet, T, Miller, J, Mundy, LM. Environmental control to reduce transmission of Clostridium difficile. Clin Infect Dis 2000;31:9951000.CrossRefGoogle ScholarPubMed
2.Boyce, JM, Havill, NL, Otter, JA, et al.Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare Setting. Infect Control Hosp Epidemiol 2008;29:723729.CrossRefGoogle Scholar
3.Otter, JA, Cummins, M, Ahmad, F, van Tonder, C, Drabu, YJ. Assessing the biological efficacy and rate of recontamination following hydrogen peroxide vapour decontamination. J Hosp Infect 2007;67:182188.CrossRefGoogle ScholarPubMed
4.Johnston, MD, Lawson, S, Otter, JA. Evaluation of hydrogen peroxide vapour as a method for the decontamination of surfaces contaminated with Clostridium botulinum spores. J Microbiol Methods 2005;60:403411.CrossRefGoogle ScholarPubMed
5.French, GL, Otter, LA, Shannon, KP, Adams, NM, Watling, D, Parks, MJ. Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination. J Hosp Infect 2004;57:3137.CrossRefGoogle ScholarPubMed
6.Bates, CJ, Pearse, R. Use of hydrogen peroxide vapour for environmental control during a Serratia outbreak in a neonatal intensive care unit. J Hosp Infect 2005;61:364366.CrossRefGoogle Scholar
7.Jeanes, A, Rao, G, Osman, M, Merrick, P. Eradication of persistent environmental MRSA. J Hosp Infect 2005;61:8586.CrossRefGoogle ScholarPubMed
8.Taneja, N, Biswal, M, Emmanuel, R, Singh, M, Sharma, M. Hydrogen peroxide fogging in an overcrowded tertiary care referral centre: some practical queries. J Hosp Infect 2005;60:85.CrossRefGoogle Scholar
9.Lawrence, SI, Puzniak, LA, Shadel, BN, Gillespie, KN, Kollef, MH, Mundy, LM. Clostridium difficile in the intensive care unit: epidemiology, costs, and colonization pressure. Infect Control Hosp Epidemiol 2007;28:123130.CrossRefGoogle ScholarPubMed
10.Passaretti, CL, Otter, JA, Lipsett, P, et al.Adherence to Hydrogen Peroxide Vapor (HPV) decontamination reduces VRE acquisition in high-risk units. Paper presented at: 48th Annual Meeting of the Interscience Conference on Antimicrobial Agents and Chemotherapy and the Infectious Diseases Society of America. October 10, 2008; Washington, DC (abstract K4124b).Google Scholar
48
Cited by

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Feasibility of Routinely Using Hydrogen Peroxide Vapor to Decontaminate Rooms in a Busy United States Hospital
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Feasibility of Routinely Using Hydrogen Peroxide Vapor to Decontaminate Rooms in a Busy United States Hospital
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Feasibility of Routinely Using Hydrogen Peroxide Vapor to Decontaminate Rooms in a Busy United States Hospital
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *