Hostname: page-component-78c5997874-t5tsf Total loading time: 0 Render date: 2024-10-31T22:59:21.347Z Has data issue: false hasContentIssue false

Immunogold-Silver Staining (IGSS) of (NCP and CP) BVDV Infected Subcellular Fraction Bands

Published online by Cambridge University Press:  02 July 2020

C.E. Hearne
Affiliation:
Department Veterinary Sciences, University of Wyoming, Laramie, WY82071
D.L. Johnson
Affiliation:
Department Veterinary Sciences, University of Wyoming, Laramie, WY82071
H. Van Campen
Affiliation:
Department Veterinary Sciences, University of Wyoming, Laramie, WY82071
Get access

Extract

Pre-embedding immunogold-silver (IGSS) techniques are useful to localize antigens in cell monolayers and agarose embedded cell suspensions for transmission electron microscopy. Procedural centrifugations, however, present a challenge when attempting to localize antigens in subcellular fractions. Using a Beckman Airfuge Ultracentrifuge to concentrate the subcellar fraction bands and resuspending the organelles in agarose simplifies IGSS processing and resin embedding procedures.

Control bovine turbinate (BT), and BT cells infected with cytopathic (cp NADL) and non-cytopathic (ncp NY-1) strains of bovine viral diarrhea virus (BVDV) were fractioned according to Bienz et al (1992). Bands containing membrane vesicles (Fig 2) were collected and each fraction band was pelleted at 169,000g for 20 min using an A-95 fixed angle rotor in a Beckman Airfuge Ultracentrifuge. Each fraction pellet was resuspended in 50μl of 30% agarose, solidified, and trimmed to < lmm. IGSS procedures were carried out according to Nanoprobes, Inc., Stoney Brook, NY, and Hearne & Van Campen (1996).

Type
Cytochemistry, Histochemistry, Immunocytochemistry, and In Situ Hybridization
Copyright
Copyright © Microscopy Society of America 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Bienz, K.et al., J.Virol, 66(1992)2740.10.1128/JVI.66.5.2740-2747.1992CrossRefGoogle Scholar
2.Hearne, C. and Van Campen, H., Proc. Ann MSA Meeting, 54(1996)902.Google Scholar
3.Nanogold™, Rev. 1.3, Nanoprobes, Inc., Stoney Brook, NY.Google Scholar
4.Tao-Cheng, J.-H. and Tanner, V.A., Proc. Ann MSA Meeting, 52(1994)306.Google Scholar
5.The authors wish to thank Dr.Dubovi, E.J., New York State Diagnostic Laboratory, Cornell University, Ithaca, NY for providing the MAb 20.10.6 used in this investigation.Google Scholar