Skip to main content Accessibility help
×
Home

Marker Detection in Electron Tomography: A Comparative Study

  • Patrick Trampert (a1) (a2), Sviatoslav Bogachev (a2), Nico Marniok (a1) (a2), Tim Dahmen (a1) (a2) and Philipp Slusallek (a1) (a2)...

Abstract

We conducted a comparative study of three widely used algorithms for the detection of fiducial markers in electron microscopy images. The algorithms were applied to four datasets from different sources. For the purpose of obtaining comparable results, we introduced figures of merit and implemented all three algorithms in a unified code base to exclude software-specific differences. The application of the algorithms revealed that none of the three algorithms is superior to the others in all cases. This leads to the conclusion that the choice of a marker detection algorithm highly depends on the properties of the dataset to be analyzed, even within the narrowed domain of electron tomography.

Copyright

Corresponding author

* Corresponding author. Tim.Dahmen@dfki.de

References

Hide All
Amat, F., Moussavi, F., Comolli, L.R., Elidan, G., Downing, K.H. & Horowitz, M. (2008). Markov random field based automatic image alignment for electron tomography. J Struct Biol 161, 260275.
Brandt, S., Heikkonen, J. & Engelhardt, P. (2001). Multiphase method for automatic alignment of transmission electron microscope images using markers. J Struct Biol 133, 1022.
Cao, M., Takaoka, A., Zhang, H.-B. & Nishi, R. (2011). An automatic method of detecting and tracking fiducial markers for alignment in electron tomography. J Electron Microsc 60, 3946.
Cheng, C.-C., Chien, C.-C., Chen, H.-H., Hwu, Y. & Ching, Y.-T. (2014). Image alignment for tomography reconstruction from synchrotron X-ray microscopic images. PLoS One 9, e84675.
Dahmen, T., Marsallek, L., Turonova, B., Marniok, N., Bogachev, S., Nickels, S. & Slusallek, P. (2015). The Ettention software package. Ultramicroscopy (in press).
Diebolder, C.A., Beurskens, F.J., de Jong, R.N., Koning, R.I., Strumane, K., Lindorfer, M.A., Voorhorst, M., Ugurlar, D., Rosati, S., Heck, A.J.R., van de Winkel, J.G.J., Wilson, I.A., Koster, A.J., Taylor, R.P., Saphire, E.O., Burton, D.R., Schuurman, J., Gros, P. & Parren, P.W.H.I. (2014). Complement is activated by IgG hexamers assembled at the cell surface. Science 343, 12601263.
Fischler, M.A. & Bolles, R.C. (1981). Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM 24, 381395.
Frank, J. (1992). Alignment by cross-correlation. In Electron Tomography , Frank, J. (Ed.), pp. 205213. Boston, MA, USA: Springer.
Frank, J. (1996). Two-dimensional averaging techniques. In Three-Dimensional Electron Microscopy of Macromolecular Assemblies: Visualization of Biological Molecules in Their Native State, Frank, J. (Ed.), pp. 131144. Oxford University Press: New York.
Hayashida, M., Terauchi, S. & Fujimoto, T. (2010). Automatic coarse-alignment for TEM tilt series of rod-shaped specimens collected with a full angular range. Micron (Oxford, England : 1993) 41, 540545.
Hell, S.W. (2007). Far-field optical nanoscopy. Science 316, 11531158.
Liu, Y., Penczek, P.A., McEwen, B.F. & Frank, J. (1995). A marker-free alignment method for electron tomography. Ultramicroscopy 58, 393402.
Lowe, D.G. (2004). Distinctive image features from scale-invariant keypoints. Int J Comput Vis 60, 91110.
Mastronarde, D.N. (2005). Fiducial marker and hybrid alignment methods for single- and double-axis tomography. In Electron Tomography, Frank, J. (Ed.), pp 163185). Boston, MA: Springer.
Meyer-Ilse, W., Hamamoto, D., Nair, A., Leliévre, S.A., Denbeaux, G., Johnson, L., Pearson, A.L., Yager, D., Legros, M.A. & Larabell, C.A. (2001). High resolution protein localization using soft X-ray microscopy. J Microsc 201, 395403.
Peckys, D.B., Bandmann, V. & de Jonge, N. (2014). Correlative fluorescence and scanning transmission electron microscopy of quantum dot-labeled proteins on whole cells in liquid. Methods Cell Biol 124, 305322.
Pierson, J., Fernández, J.J., Bos, E., Amini, S., Gnaegi, H., Vos, M., Bel, B., Adolfsen, F., Carrascosa, J.L. & Peters, P.J. (2010). Improving the technique of vitreous cryo-sectioning for cryo-electron tomography: Electrostatic charging for section attachment and implementation of an anti-contamination glove box. J Struct Biol 169, 219225.
Ress, D., Harlow, M.L., Schwarz, M., Marshall, R.M. & McMahan, U.J. (1999). Automatic acquisition of fiducial markers and alignment of images in tilt series for electron tomography. J Electron Microsc 48, 277287.
Sorzano, C.O.S., Messaoudi, C., Eibauer, M., Bilbao-Castro, J.R., Hegerl, R., Nickell, S., Marco, S. & Carazo, J.M. (2009). Marker-free image registration of electron tomography tilt-series. BMC Bioinformatics 10, 124.
Sosinsky, G.E., Crum, J., Jones, Y.Z., Lanman, J., Smarr, B., Terada, M., Martone, M.E., Deerinck, T.J., Johnson, J.E. & Ellisman, M.H. (2008). The combination of chemical fixation procedures with high pressure freezing and freeze substitution preserves highly labile tissue ultrastructure for electron tomography applications. J Struct Biol 161, 359371.
Tversky, A. (1977). Features of Similarity. Psych Reviews 84, 327352.
Voortman, L.M., Stallinga, S., Schoenmakers, R.H.M., van Vliet, L.J. & Rieger, B. (2011). A fast algorithm for computing and correcting the CTF for tilted, thick specimens in TEM. Ultramicroscopy 111, 10291036.

Keywords

Related content

Powered by UNSILO

Marker Detection in Electron Tomography: A Comparative Study

  • Patrick Trampert (a1) (a2), Sviatoslav Bogachev (a2), Nico Marniok (a1) (a2), Tim Dahmen (a1) (a2) and Philipp Slusallek (a1) (a2)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.