Skip to main content Accessibility help
×
Home

On the Progress of Scanning Transmission Electron Microscopy (STEM) Imaging in a Scanning Electron Microscope

  • Cheng Sun (a1), Erich Müller (a1), Matthias Meffert (a1) and Dagmar Gerthsen (a1)

Abstract

Transmission electron microscopy (TEM) with low-energy electrons has been recognized as an important addition to the family of electron microscopies as it may avoid knock-on damage and increase the contrast of weakly scattering objects. Scanning electron microscopes (SEMs) are well suited for low-energy electron microscopy with maximum electron energies of 30 keV, but they are mainly used for topography imaging of bulk samples. Implementation of a scanning transmission electron microscopy (STEM) detector and a charge-coupled-device camera for the acquisition of on-axis transmission electron diffraction (TED) patterns, in combination with recent resolution improvements, make SEMs highly interesting for structure analysis of some electron-transparent specimens which are traditionally investigated by TEM. A new aspect is correlative SEM, STEM, and TED imaging from the same specimen region in a SEM which leads to a wealth of information. Simultaneous image acquisition gives information on surface topography, inner structure including crystal defects and qualitative material contrast. Lattice-fringe resolution is obtained in bright-field STEM imaging. The benefits of correlative SEM/STEM/TED imaging in a SEM are exemplified by structure analyses from representative sample classes such as nanoparticulates and bulk materials.

Copyright

Corresponding author

* Author for correspondence: Cheng Sun, E-mail: cheng.sun@kit.edu

References

Hide All
Ambacher, O (1998) Growth and applications of Group III-nitrides. J Phys D Appl Phys 31, 26532710.
Belin, T and Epron, F (2005) Characterization methods of carbon nanotubes: A review. Mater Sci Eng B 119, 105118.
Bell, DC and Erdman, N (2013) Low Voltage Electron Microscopy: Principles and Applications. West Sussex: John Wiley & Sons.
Bell, DC, Mankin, M, Day, RW and Erdman, N (2014) Successful application of low voltage electron microscopy to practical materials problems. Ultramicroscopy 145, 5665.
Bell, DC, Russo, CJ and Kolmykov, DV (2012) 40keV atomic resolution TEM. Ultramicroscopy 114, 3137.
Blank, H, Schneider, R, Gerthsen, D, Gehrke, H, Jarolim, K and Marko, D (2014) Application of low-energy scanning transmission electron microscopy for the study of Pt-nanoparticle uptake in human colon carcinoma cells. Nanotoxicology 8, 433446.
Brodu, E, Bouzy, E, Fundenberger, J-J, Guyon, J, Guitton, A and Zhang, Y (2017) On-axis TKD for orientation mapping of nanocrystalline materials in SEM. Mater Character 130, 9296.
Cao, J, Liu, F, Lin, Q and Zhang, Y (2008) Hydrothermal synthesis of xonotlite from carbide slag. Prog Nat Sci 18, 11471153.
Cazaux, J (2012) From the physics of secondary electron emission to image contrasts in scanning electron microscopy. J Electron Microsc 61, 261284.
Cretu, O, Lin, Y-C and Suenaga, K (2015) Secondary electron imaging of monolayer materials inside a transmission electron microscope. Appl Phys Lett 107, 063105.
Dellby, N, Bacon, NJ, Hrncirik, P, Murfitt, MF, Skone, GS, Szilagyi, ZS and Krivanek, OL (2011) Dedicated STEM for 200 to 40 keV operation. Eur Phys J Appl Phys 54, 33505.
Demers, H, Brodusch, N and Gauvin, R (2017) Low accelerating voltage scanning transmitted electron microscope: Imaging, diffraction, X-ray microanalysis, and electron energy-loss spectroscopy at the nanoscale. Microsc Microanal 23, 528529.
Egerton, RF (2014) Choice of operating voltage for a transmission electron microscope. Ultramicroscopy 145, 8593.
Goudsmit, S and Saunderson, JL (1940) Multiple scattering of electrons. Phys Rev 57, 2429.
Han, M-G, Garlow, JA, Marshall, MSJ, Tiano, AL, Wong, SS, Cheong, S-W, Walker, FJ, Ahn, CH and Zhu, Y (2017) Electron-beam-induced-current and active secondary-electron voltage-contrast with aberration-corrected electron probes. Ultramicroscopy 177, 1419.
Hejny, C and Armbruster, T (2001) Polytypism in xonotlite Ca6Si6O17(OH)2 . Z Kristallogr 216, 396408.
Hondow, N, Harrington, J, Brydson, R, Doak, SH, Singh, N, Manshian, B and Brown, A (2011) STEM mode in the SEM: A practical tool for nanotoxicology. Nanotoxicology 5, 215227.
Howie, A (1979) Image contrast and localized signal selection techniques. J Microsc 117, 1123.
Iakoubovskii, K, Mitsuishi, K, Nakayama, Y and Furuya, K (2008) Thickness measurements with electron energy loss spectroscopy. Microsc Res Techniq 71, 626631.
Joy, DC and Luo, S (1989) An empirical stopping power relationship for low-energy electrons. Scanning 11, 176180.
Kaiser, U, Biskupek, J, Meyer, JC, Leschner, J, Lechner, L, Rose, H, Stöger-Pollach, M, Khlobystov, AN, Hartel, P, Müller, H, Haider, M, Eyhusen, S and Benner, G (2011) Transmission electron microscopy at 20kV for imaging and spectroscopy. Ultramicroscopy 111, 12391246.
Keller, RR and Geiss, RH (2012) Transmission EBSD from 10 nm domains in a scanning electron microscope. J Microsc 245, 245251.
Kim, YJ, Kriven, WM and Mitsuda, T (1993) TEM study of synthetic hillebrandite (Ca2SiO4· H2O). J Mater Res 8, 29482953.
Klaar, H-J and Hsu, F-Y (1996) A new preparation method for cross-sectional TEM specimens. Mater Charact 36, 365369.
Klein, T, Buhr, E and Georg Frase, C (2012) TSEM: A review of scanning electron microscopy in transmission mode and its applications. Adv Imag Elect Phys 171, 297348.
Konno, M, Ogashiwa, T, Sunaoshi, T, Orai, Y and Sato, M (2014) Lattice imaging at an accelerating voltage of 30kV using an in-lens type cold field-emission scanning electron microscope. Ultramicroscopy 145, 2835.
Krivanek, OL, Chisholm, MF, Nicolosi, V, Pennycook, TJ, Corbin, GJ, Dellby, N, Murfitt, MF, Own, CS, Szilagyi, ZS, Oxley, MP, Pantelides, ST and Pennycook, SJ (2010) Atom-by-atom structural and chemical analysis by annular dark-field electron microscopy. Nature 464, 571574.
Krumeich, F, Müller, E, Wepf, RA and Nesper, R (2011) Characterization of catalysts in an aberration-corrected scanning transmission electron microscope. J Phys Chem C 115, 10801083.
Linck, M, Hartel, P, Uhlemann, S, Kahl, F, Müller, H, Zach, J, Haider, M, Biskupek, J, Lee, Z, Lehnert, T, Börrnert, F, Rose, H and Kaiser, U (2016) Chromatic aberration correction for atomic resolution TEM imaging from 20 to 80 kV. Phys Rev Lett 117, 076101.
Merli, PG and Morandi, V (2005) Low-energy STEM of multilayers and dopant profiles. Microsc Microanal 11, 97104.
Michael, JR, Joy, DC and Griffin, BJ (2009) Challenges in achieving high resolution at low voltages in the SEM. Microsc Microanal 15, 660661.
Morandi, V and Merli, PG (2007) Contrast and resolution versus specimen thickness in low energy scanning transmission electron microscopy. J Appl Phys 101, 114917.
Morandi, V, Merli, PG and Quaglino, D (2007) Scanning electron microscopy of thinned specimens: From multilayers to biological samples. Appl Phys Lett 90, 163113.
Negreanu, C, Llovet, X, Chawla, R and Salvat, F (2005) Calculation of multiple-scattering angular distributions of electrons and positrons. Radiat Phys Chem 74, 264281.
Pfaff, M, Klein, MFG, Müller, E, Müller, P, Colsmann, A, Lemmer, U and Gerthsen, D (2012) Nanomorphology of P3HT: PCBM-based absorber layers of organic solar cells after different processing conditions analyzed by low-energy scanning transmission electron microscopy. Microsc Microanal 18, 13801388.
Pfaff, M, Müller, E, Klein, MFG, Colsmann, A, Lemmer, U, Krzyzanek, V, Reichelt, R and Gerthsen, D (2011) Low-energy electron scattering in carbon-based materials analyzed by scanning transmission electron microscopy and its application to sample thickness determination. J Microsc 243, 3139.
Reimer, L (1998) Scanning Electron Microscopy: Physics of Image Formation and Microanalysis. Berlin, Heidelberg: Springer-Verlag.
Rose, ME (1940) Electron path lengths in multiple scattering. Phys Rev 58, 90.
Sasaki, T, Sawada, H, Okunishi, E, Hosokawa, F, Kaneyama, T, Kondo, Y, Kimoto, K and Suenaga, K (2012) Evaluation of probe size in STEM imaging at 30 and 60kV. Micron 43, 551556.
Sasaki, T, Sawada, H, Hosokawa, F, Sato, Y and Suenaga, K (2014) Aberration-corrected STEM/TEM imaging at 15kV. Ultramicroscopy 145, 5055.
Suenaga, K, Sato, Y, Liu, Z, Kataura, H, Okazaki, T, Kimoto, K, Sawada, H, Sasaki, T, Omoto, K, Tomita, T, Kaneyama, T and Kondo, Y (2009) Visualizing and identifying single atoms using electron energy-loss spectroscopy with low accelerating voltage. Nat Chem 1, 415418.
Uhlemann, S, Müller, H, Hartel, P, Zach, J and Haider, M (2013) Thermal magnetic field noise limits resolution in transmission electron microscopy. Phys Rev Lett 111, 046101.
Van Ngo, V, Hernandez, M, Roth, B and Joy, DC (2007) STEM imaging of lattice fringes and beyond in a UHR In-lens field-emission SEM. Microscopy Today 15, 1216.
Volkenandt, T, Müller, E and Gerthsen, D (2014) Sample thickness determination by scanning transmission electron microscopy at low electron energies. Microsc Microanal 20, 111123.
Volkenandt, T, Müller, E, Hu, DZ, Schaadt, DM and Gerthsen, D (2010) Quantification of sample thickness and In-concentration of InGaAs quantum wells by transmission measurements in a scanning electron microscope. Microsc Microanal 16, 604613.
Weidner, A and Biermann, H (2015) Case studies on the application of high-resolution electron channelling contrast imaging–Investigation of defects and defect arrangements in metallic materials. Philos Mag 95, 759793.
Williams, DB and Carter, BC (2009) Transmission Electron Microscopy: A Textbook for Materials Science. New York, NY: Springer Science Business Media.
Yi, G-C, Wang, C and Park, WI (2005) ZnO nanorods: Synthesis, characterization and applications. Semicond Sci Technol 20, 2234.
Zhu, Y, Inada, H, Nakamura, K and Wall, J (2009) Imaging single atoms using secondary electrons with an aberration-corrected electron microscope. Nat Mater 8, 808812.

Keywords

On the Progress of Scanning Transmission Electron Microscopy (STEM) Imaging in a Scanning Electron Microscope

  • Cheng Sun (a1), Erich Müller (a1), Matthias Meffert (a1) and Dagmar Gerthsen (a1)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed