Skip to main content Accessibility help
×
Hostname: page-component-848d4c4894-xm8r8 Total loading time: 0 Render date: 2024-06-16T16:39:41.811Z Has data issue: false hasContentIssue false

Chapter 24 - Set-Up and Adapted Protocol for Piezo-ICSI

from Section 4 - Insemination/ICSI

Published online by Cambridge University Press:  07 August 2023

Markus H. M. Montag
Affiliation:
ilabcomm GmbH, St Augustin, Germany
Dean E. Morbeck
Affiliation:
Kindbody Inc, New York City
Get access

Summary

Piezo-ICSI is one of the intracytoplasmic sperm injection (ICSI) techniques using a piezo-actuator. This technique requires the use of a drive unit, a micropipette with a blunt-ended tip and an operation liquid. Piezo-ICSI can be applied for sperm immobilization, opening of the zona pellucida without oocyte deformation, and to semi-automatically break the oolemma membrane without the need for aspiration of cytoplasm into the injection pipette. The piezo-ICSI process is stable and easy and can contribute to standardizing the ICSI technique. In this chapter, we describe the set-up and protocol of piezo-ICSI for human oocytes.

Type
Chapter
Information
Principles of IVF Laboratory Practice
Laboratory Set-Up, Training and Daily Operation
, pp. 178 - 185
Publisher: Cambridge University Press
Print publication year: 2023

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Palermo, G., Joris, H., Devroey, P. and Van Steirteghem, A. C. Pregnancies after intracytoplasmic injection of single spermatozoon into an oocyte. Lancet 1992; 340 (8810):1718.CrossRefGoogle ScholarPubMed
Kimura, Y. and Yanagimachi, R. Intracytoplasmic sperm injection in the mouse. Biol Reprod 1995; 52(4):709–20.CrossRefGoogle ScholarPubMed
Huang, T., Kimura, Y. and Yanagimachi, R. The use of piezo micromanipulation for intracytoplasmic sperm injection of human oocytes. J Assist Reprod Genet 1996; 13(4):320–8.CrossRefGoogle ScholarPubMed
Yanagida, K., Katayose, H., Yazawa, H., et al. The usefulness of a piezo-micromanipulator in intracytoplasmic sperm injection in humans. Hum Reprod 1999; 14(2):448–3.CrossRefGoogle ScholarPubMed
Takeuchi, S., Minoura, H., Shibahara, T., et al. Comparison of piezo-assisted micromanipulation with conventional micromanipulation for intracytoplasmic sperm injection into human oocytes. Gyn Obstet Invest 2001; 52(3):158–62.Google ScholarPubMed
Hiraoka, K. and Kitamura, S. Clinical efficiency of Piezo-ICSI using micropipettes with a wall thickness of 0.625 μm. J Assist Reprod Genet 2015; 32(12):1827–33.CrossRefGoogle Scholar
Furuhashi, K., Saeki, Y., Enatsu, N., et al. Piezo-assisted ICSI improves fertilization and blastocyst development rates compared with conventional ICSI in women aged more than 35 years. Reprod Med Biol 2019; 18(4):357–61.CrossRefGoogle Scholar
Fujii, Y., Endo, Y., Mitsuhata, S., Hayashi, M. and Motoyama, H. Evaluation of the effect of piezo-intracytoplasmic sperm injection on the laboratory, clinical, and neonatal outcomes. Reprod Med Biol 2020; 19(2):198205.Google Scholar
Setti, A. S., Ferreira, R. C., Braga, D., et al. Intracytoplasmic sperm injection outcome versus intracytoplasmic morphologically selected sperm injection outcome: a meta-analysis. Reprod Biomed Online 2010; 21(4):450–5.Google Scholar
Montag, M., Schimming, T. and van der Ven, H. Spindle imaging in human oocytes: the impact of the meiotic cell cycle. Reprod Biomed Online 2006; 12(4):442–6.CrossRefGoogle ScholarPubMed
Menz, D. H., Feltgen, T., Menz, H., et al. How to ward off retinal toxicity of perfluorooctane and other perfluorocarbon liquids? Invest Ophtalmol Vis Sci 2018; 59(12):4841–6.Google ScholarPubMed

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×