Hostname: page-component-8448b6f56d-tj2md Total loading time: 0 Render date: 2024-04-25T04:19:42.068Z Has data issue: false hasContentIssue false

The Application of X-Ray Diffraction for Glass Batch Homogeneity Determination

Published online by Cambridge University Press:  06 March 2019

H. S. Kim
Affiliation:
Owens-Corning Fiberglas Corporation Technical Center Granville, OH 43023
C. I. Cohen
Affiliation:
Owens-Corning Fiberglas Corporation Technical Center Granville, OH 43023
Get access

Abstract

An X-ray diffraction (XRD) technique is employed to determine the presence or absence of crystalline phases in glass batch and to determine its homogeneity qualitatively and quantitatively.

Sample preparation problems are discussed, and promising techniques for sample preparation are presented. Qualitative batch homogeneity determination is accomplished by comparing the integrated intensity of a particular reflection of the reference sample to that of the unknown sample. Quantitative batch determination is accomplished by using the internal standard method. Three replicated data sets indicate that the standard deviation of kaolinite and colemanite are higher than those of quartz and calcite. However, the overall data from the quantitative analyses lie within an acceptable range of precision and accuracy.

Type
VIII. XRD Applications
Copyright
Copyright © International Centre for Diffraction Data 1981

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Klug, H. P. and Alexander, L. E., X-ray diffraction procedures, 2nd Ed., John Wiley and Sons (1974), p. 365376.Google Scholar