Skip to main content
×
×
Home

LO61: Test characteristics of high sensitivity troponin T performed at emergency department arrival for acute myocardial infarction in patients with reduced kidney function

  • A. D. McRae (a1), S. Vatanpour (a1), J. Ji (a1), H. Yang (a1), D. Southern (a1), D. Wang (a1), I. Seiden-Long (a1), L. DeKoning (a1), M. Graham (a1), E. S. Lang (a1), G. Innes (a1), J. E. Andruchow (a1), P. Kavsak (a1) and M. James (a1)...
Abstract

Introduction: Patients with chronic kidney disease (CKD) are at high risk of cardiovascular events, and have worse outcomes following acute myocardial infarction (AMI). Cardiac troponin is often elevated in CKD, making the diagnosis of AMI challenging in this population. We sought to quantify test characteristics for AMI of a high-sensitivity troponin T (hsTnT) assay performed at emergency department (ED) arrival in CKD patients with chest pain, and to derive rule-out cutoffs specific to patient subgroups stratified by estimated glomerular filtration rate (eGFR). We also quantified the sensitivity and classification performance of the assays limit of detection (5 ng/L) and the FDA-approved limit of quantitation (6 ng/L) for ruling out AMI at ED arrival. Methods: Consecutive patients in four urban EDs from the 2013 calendar year with suspected cardiac chest pain who had a Roche Elecsys hsTnT assay performed on arrival were included f. This analysis was restricted to patients with an eGFR< 60 ml/min/1.73m2. The primary outcome was 7-day AMI. Secondary outcomes included major adverse cardiac events (death, AMI and revascularization). Test characteristics were calculated and ROC curves were generated for eGFR subgroups. Results: 1416 patients were included. 7-day AMI incidence was 10.1%. 73% of patients had an initial hsTnT concentration greater than the assays 99th percentile (14 ng/L). TCurrently accepted cutoffs to rule out MI at ED arrival ( 5 ng/L and 6 ng/L) had 100% sensitivity for AMI, but no patients with an eGFR less than 30 ml/min/1.73M had hsTnT concentrations below these thresholds. We derived eGFR-adjusted cutoffs to rule out MI with sensitivity >98% at ED arrival, which were able to rule out 6-42% of patients, depending on eGFR category. The proportion of patients able to be accurately ruled-in with a single hsTnT assay was substantially lower among patients with an eGFR <30 ml/min/1.73m2 (6-20% vs 25-43%). We also derived eGFR-adjusted cutoffs to rule-in AMI with specificity >90%, which accurately ruled-in up to 18% of patients. Conclusion: Cutoffs achieving acceptable diagnostic performance for AMI using single hsTnT sampling on ED arrival may have limited clinical utility, particularly among patients with very low eGFR. The ideal diagnostic strategy for AMI in patients with CKD likely involves serial high-sensitivity troponin testing with diagnostic thresholds customized to different eGFR categories.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      LO61: Test characteristics of high sensitivity troponin T performed at emergency department arrival for acute myocardial infarction in patients with reduced kidney function
      Available formats
      ×
      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      LO61: Test characteristics of high sensitivity troponin T performed at emergency department arrival for acute myocardial infarction in patients with reduced kidney function
      Available formats
      ×
      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      LO61: Test characteristics of high sensitivity troponin T performed at emergency department arrival for acute myocardial infarction in patients with reduced kidney function
      Available formats
      ×
Copyright
Corresponding author
*Corresponding author
Recommend this journal

Email your librarian or administrator to recommend adding this journal to your organisation's collection.

Canadian Journal of Emergency Medicine
  • ISSN: -
  • EISSN: 1481-8035
  • URL: /core/journals/canadian-journal-of-emergency-medicine
Please enter your name
Please enter a valid email address
Who would you like to send this to? *
×

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed