Disinfection of a Probe Used in Ultrasound-Guided Prostate Biopsy

Published online by Cambridge University Press:  02 January 2015

William A. Rutala*
Affiliation:
Department of Hospital Epidemiology, University of North Carolina Health Care System, Chapel Hill Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill
Maria F. Gergen
Affiliation:
Department of Hospital Epidemiology, University of North Carolina Health Care System, Chapel Hill
David J. Weber
Affiliation:
Department of Hospital Epidemiology, University of North Carolina Health Care System, Chapel Hill Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill
*
Division of Infectious Diseases, 130 Mason Farm Road, Bioinformatics, UNC at Chapel Hill, Chapel Hill, NC 27599-7030 (brutala@unch.unc.edu)

Abstract

Background.

Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection.

Objective.

To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy.

Method.

The effectiveness of disinfection was determined by inoculating 107 colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination.

Results.

The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log10 cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log10 cfu).

Conclusions.

Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Centers for Disease Control and Prevention (CDC). Ambulatory and Inpatient Procedures in the United States, 1996. Atlanta: CDC; 1998:139.Google Scholar
2. Centers for Disease Control and Prevention. Pseudomonas aeruginosa infections associated with transrectal ultrasound-guided prostate biopsies- Georgia, 2005. MMWR Morb Mortal Wkly Rep 2006;55:776777.Google Scholar
3. Weber, DI, Rutala, WA, DiMarino, AJ Jr. The prevention of infection following gastrointestinal endoscopy: the importance of prophylaxis and reprocessing. In: DiMarino, AJ Jr, Benjamin, SB, eds. Gastrointestinal Diseases: An Endoscopic Approach. Thorofare, NJ: Slack; 2002:87106.Google Scholar
4. Rutala, WA, Weber, DJ. Guideline for disinfection and sterilization in healthcare facilities: recommendations of CDC. Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep. In press.Google Scholar
5. Scott, EM, Gorman, SP. Glutaraldehyde. In: Block, SS, ed. Disinfection, Sterilization, and Preservation. Philadelphia: Lippincott Williams & Willems; 2001:361381.Google Scholar
6. US Food and Drug Administration. FDA public health notification: reprocessing of reusable ultrasound transducer assemblies used for biopsy procedures, 2006. Available at: http://www.fda.gov/cdrh/safety/061906-ul-trasoundtransducers.html. Accessed May 17, 2007.Google Scholar
7. Rutala, WA, Weber, DI. How to assess risk of disease transmission when there is a failure to follow recommended disinfection and sterilization guidelines. Infect Control Hosp Epidemiol 2007;28:146155.Google Scholar
8. Favero, MS. Sterility assurance: concepts for patient safety. In: Rutala, WA, ed. Disinfection, Sterilization and Antisepsis: Principles and Practices in Healthcare Facilities. Washington, DC: Association for Professionals in Infection Control and Epidemiology; 2001:110119.Google Scholar