PP095 Assessment Of Magmaris Resorbable Metal Stent In Patients With Angina

Published online by Cambridge University Press:  12 January 2018

Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.
INTRODUCTION:

Ischaemic heart disease is the leading cause of death worldwide. Magmaris™ is a new drug-eluting resorbable stent used for coronary reperfusion during a balloon angioplasty. Magmaris™ is composed of absorbable magnesium scaffold and its surface is coated with bioresorbable poly-L-lactide, which incorporates Sirolimus. Magmaris™ has theoretical advantages as the stent body disappears after vascular constrictive remodeling. It would provide the stability and elasticity of non-resorbable metal stents, but without long-term problems such as endothelial dysfunction, delay in endothelialization, risk of thrombosis and complications due to long-term antiplatelet medication. The objective of this work is to assess efficacy and safety of Magmaris ™ in patients with angina or silent ischaemia.

METHODS:

Early assessment of Magmaris™ identified through the Early-Awareness and Alert-System, “SINTESIS-new technologies”, of The Instituto De Salud Carlos III (AETS-ISCIII). The searched databases were: MEDLINE (PubMed), EMBASE, WOS, Clinical Trials and Cochrane Library. Clinical studies using Magmaris™ published in any language until December 2016 were reviewed.

RESULTS:

One prospective, non-randomized, non-controlled, multicenter, clinical trial with two publications was retrieved. The first publication (123 patients) showed mainly imaging outcomes of angiography, intravascular ultrasound and tomography at 6 months of follow up. The second publication (118 patients) with data from 12 months of follow up also reported: Target lesion failure in four patients (3.4 percent; 95 percent Confidence Interval, CI:0.9–8.4); one target-vessel myocardial infarction (0.8 percent; one myocardial infarction (0.8 percent); two clinically driven target lesion revascularisation (1.7 percent) and two clinically driven target-vessel revascularisation (1.7 percent). No definite scaffold thrombosis was observed. No procedural complications were reported. This trial is expected to continue up to 36 months of follow up.

CONCLUSIONS:

Clinical data show that Magmaris™ seems to be an effective and safe treatment in patients with angina or silent ischaemia undergoing balloon angioplasty. More research specially randomized controlled trials are necessary to confirm these results.